5<\/sup><\/td>\n<\/tr>\n\nSemiconductor output<\/th>\n<\/tr>\n |
\nMax switching voltage<\/td>\n | 30 V DC<\/td>\n<\/tr>\n |
\nMax. switching current<\/td>\n | 50 mA DC<\/td>\n<\/tr>\n |
\nSupply<\/th>\n<\/tr>\n |
\nVoltage range AC<\/td>\n | 50 … 250 V AC, 50\/60 Hz<\/td>\n<\/tr>\n |
\nNominal voltage AC<\/td>\n | 230 V AC<\/td>\n<\/tr>\n |
\nPower consumption AC<\/td>\n | 3,5 VA (2,3 VA ; KVEX 100 GVD)<\/td>\n<\/tr>\n |
\nVoltage range DC<\/td>\n | 20 … 120 V DC<\/td>\n<\/tr>\n |
\nNominal voltage DC<\/td>\n | 24 V DC<\/td>\n<\/tr>\n |
\nPower consumption DC<\/td>\n | 1,8 W (1W ; KVEX 100 GVD)<\/td>\n<\/tr>\n |
\nTransmission behaviour<\/th>\n<\/tr>\n |
\nResponse time<\/td>\n | ~ 100 ms<\/td>\n<\/tr>\n |
\nHousing<\/th>\n<\/tr>\n |
\nDimensions (WxHxD)<\/td>\n | 23 x 110 x 134 mm<\/td>\n<\/tr>\n |
\nType of protection<\/td>\n | IP 20<\/td>\n<\/tr>\n |
\nConnection method<\/td>\n | Detachable terminal clamp<\/td>\n<\/tr>\n |
\nTerminals, wire cross section<\/td>\n | 2,5 mm\u00b2 flex wire \/ 4 mm\u00b2 one wire<\/td>\n<\/tr>\n |
\nBolting torque terminals<\/td>\n | 0,5 Nm<\/td>\n<\/tr>\n |
\nWeight<\/td>\n | ~ 115 g<\/td>\n<\/tr>\n |
\nManner of fastening<\/td>\n | 35 mm DIN rail 35mm (EN50022)<\/td>\n<\/tr>\n |
\nEnvironmental conditions<\/th>\n<\/tr>\n |
\nAmbient temperature<\/td>\n | -20 … +60 \u00b0C<\/td>\n<\/tr>\n |
\nStorage and transport<\/td>\n | -20 … +70 \u00b0C (no condensation)<\/td>\n<\/tr>\n |
\nApproval<\/th>\n<\/tr>\n |
\nATEX<\/td>\n | II(1) G [Ex ia Ga] IIC \nII(1) D [Ex ia Da] IIIC<\/td>\n<\/tr>\n |
\nEU-Type Examination Certificate<\/td>\n | BVS 16 ATEX E 038 X<\/td>\n<\/tr>\n |
\nSafety Specifications per channel<\/th>\n<\/tr>\n |
\nVoltage Uo<\/td>\n | 9,56 V DC<\/td>\n<\/tr>\n |
\nCurrent Io<\/td>\n | 10,62 mA DC<\/td>\n<\/tr>\n |
\nPower Po<\/td>\n | 25,4 mW<\/td>\n<\/tr>\n |
\nMax. external capacitance Co \n||C \n||B |||C \n||A<\/td>\n | 3,6 \u00b5F \n26 \u00b5F \n210 \u00b5F<\/td>\n<\/tr>\n |
\nMax. external inductance Lo \n||C \n||B |||C \n||A<\/td>\n | 315 mH \n1261 mH \n2522 mH<\/td>\n<\/tr>\n |
\nMax. external inductance \/ resistance ratio Lo\/Ro \n||C \n||B |||C \n||A<\/td>\n | 1,41 mH\/Ohm \n5,65 mH\/Ohm \n11,3 mH\/Ohm<\/td>\n<\/tr>\n |
\nInternal capacitance Ci<\/td>\n | N\/A<\/td>\n<\/tr>\n |
\nInternal inductance Li<\/td>\n | N\/A<\/td>\n<\/tr>\n |
\nSafety Specifications 2 channels parallel<\/th>\n<\/tr>\n |
\nVoltage Uo<\/td>\n | 9,56 V DC<\/td>\n<\/tr>\n |
\nCurrent Io<\/td>\n | 21,24 mA DC<\/td>\n<\/tr>\n |
\nPower Po<\/td>\n | 50,8 mW<\/td>\n<\/tr>\n |
\nMax. external capacitance Co \n||C \n||B |||C \n||A<\/td>\n | 3,6 \u00b5F \n26 \u00b5F \n210 \u00b5F<\/td>\n<\/tr>\n |
\nMax. external inductance Lo \n||C \n||B |||C \n||A<\/td>\n | 78,8 mH \n315,25 mH \n630,5 mH<\/td>\n<\/tr>\n |
\nMax. external inductance \/ resistance ratio Lo\/Ro \n||C \n||B |||C \n||A<\/td>\n | 0,706 mH\/Ohm \n2,826 mH\/Ohm \n5,565 mH\/Ohm<\/td>\n<\/tr>\n |
\nInternal capacitance Ci<\/td>\n | N\/A<\/td>\n<\/tr>\n |
\nInternal inductance Li<\/td>\n | N\/A<\/td>\n<\/tr>\n |
\nEMC<\/th>\n<\/tr>\n |
\nProduct family standard<\/td>\n | EN 61326-1\u00a01)<\/sup><\/small><\/td>\n<\/tr>\n\nEmitted interference<\/td>\n | EN 55011, CISPR11 Cl. B, Gr. 1<\/td>\n<\/tr>\n | \nElectrical safety requirements<\/th>\n<\/tr>\n | \nProduct family standard<\/td>\n | EN 61010-1<\/td>\n<\/tr>\n | \nOvervoltage category<\/td>\n | II<\/td>\n<\/tr>\n | \nPollution degree<\/td>\n | 2<\/td>\n<\/tr>\n | \nGalvanic isolation, test voltages<\/th>\n<\/tr>\n | \nInput \/ output<\/td>\n | 3 kV, 50 Hz (1 min.)<\/td>\n<\/tr>\n | \nSignal \/ supply unit<\/td>\n | 3 kV, 50 Hz (1 min.)<\/td>\n<\/tr>\n | \nProtection circuits<\/th>\n<\/tr>\n | \nInput<\/td>\n | Electrical surge protection<\/td>\n<\/tr>\n | \nPower supply<\/td>\n | Protection against over voltage, over temperature and reverse polarity<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n <\/p>\n
adamczewski elektronische messtechnik-EX-COMPONENTS<\/a>\n\u63a5\u89e6\u653e\u5927\u5668<\/a>\n\u6a21\u62df\u6807\u51c6\u4fe1\u53f7<\/a>\n\u9632\u7206\u96f6\u90e8\u4ef6<\/a><\/div>","protected":false},"excerpt":{"rendered":"\u6a21\u62df\u6807\u51c6\u4fe1\u53f7 AD-STVEX 710 GVD \u4ea7\u54c1\u4ecb\u7ecd \u7535\u6e90\u9694\u79bb\u653e\u5927\u5668\u7528\u4e8e\u4e3a\u5b89\u88c5\u5728\u5371\u9669\u533a\u57df\u7684\u53d8\u9001\u5668\u63d0\u4f9b\u672c\u8d28\u5b89\u5168\u7535\u6e90\u3002\u7535\u6e90\u9694\u79bb\u653e\u5927\u5668\u672c\u8eab\u4f5c\u4e3a\u76f8\u5173\u7535\u6c14\u8bbe\u5907\u5b89\u88c5\u5728\u975e\u5371\u9669\u533a\u57df\uff08\u5373\u5b89\u5168\u533a\u57df <\/p>\n","protected":false},"author":30,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[17],"tags":[18,21,20,19],"yoast_head":"\n adamczewski elektronische messtechnik-EX-COMPONENTS \u9632\u7206\u96f6\u90e8\u4ef6 \u6a21\u62df\u6807\u51c6\u4fe1\u53f7 \u63a5\u89e6\u653e\u5927\u5668<\/title>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\t\n\t\n\t\n | |