{"id":21786,"date":"2023-10-29T15:14:47","date_gmt":"2023-10-29T07:14:47","guid":{"rendered":"https:\/\/www.bihec.com\/adev\/?p=21786"},"modified":"2023-10-29T15:14:47","modified_gmt":"2023-10-29T07:14:47","slug":"%e6%84%8f%e5%a4%a7%e5%88%a9-adev-atlas-900-in-situ-%e5%8f%af%e8%b0%83%e4%ba%8c%e6%9e%81%e7%ae%a1%e6%bf%80%e5%85%89%e5%90%b8%e6%94%b6%e5%85%89%e8%b0%b1%e5%ad%a6%ef%bc%88tdlas%ef%bc%89","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/adev\/%e6%84%8f%e5%a4%a7%e5%88%a9-adev-atlas-900-in-situ-%e5%8f%af%e8%b0%83%e4%ba%8c%e6%9e%81%e7%ae%a1%e6%bf%80%e5%85%89%e5%90%b8%e6%94%b6%e5%85%89%e8%b0%b1%e5%ad%a6%ef%bc%88tdlas%ef%bc%89\/","title":{"rendered":"\u610f\u5927\u5229 ADEV AtLAS-900 \u2013 In Situ \u53ef\u8c03\u4e8c\u6781\u7ba1\u6fc0\u5149\u5438\u6536\u5149\u8c31\u5b66\uff08TDLAS\uff09\u5206\u6790\u4eea"},"content":{"rendered":"
AtLAS-900 \u662f\u4e00\u6b3e\u9002\u7528\u4e8e\u5de5\u4e1a\u5728\u7ebf\u5e94\u7528\u7684\u6fc0\u5149\u6c14\u4f53\u5206\u6790\u4eea\uff0c\u80fd\u591f\u539f\u4f4d\uff08\u8de8\u5806\u6808\uff09\u6d4b\u91cf\u5927\u91cf\u6c14\u4f53\u3002<\/span><\/p>\n TDLAS \u6280\u672f\u63d0\u4f9b\u4e86\u4ee4\u4eba\u96be\u4ee5\u7f6e\u4fe1\u7684\u5feb\u901f\u54cd\u5e94\u65f6\u95f4\u3001\u5c0f\u6f02\u79fb\u548c\u51e0\u4e4e\u4e0d\u53d7\u5176\u4ed6\u6c14\u4f53\u5e72\u6270\u7684\u6d4b\u91cf\u3002<\/span><\/p>\n \u00a0AtLAS-900 \u9488\u5bf9\u91cd\u5de5\u4e1a\u5e94\u7528\u8fdb\u884c\u4e86\u4f18\u5316\uff0c\u5e76\u53ef\u7528\u4e8e\u5b89\u5168\u6216\u5371\u9669\u533a\u57df\u5e94\u7528\uff08ATEX 1 \u533a\/21 \u533a\uff09\uff0c\u5177\u6709\u975e\u5e38\u575a\u56fa\u7684\u8bbe\u8ba1\uff0c\u5e76\u914d\u5907\u4e86\u6613\u4e8e\u5b89\u88c5\u548c\u5b9a\u671f\u6821\u51c6\u6240\u9700\u7684\u6240\u6709\u9644\u4ef6\u3002<\/span><\/p>\n <\/p>\n <\/p>\n <\/p>\n <\/p>\n \u6c27\u6c14 [O2]<\/span><\/p>\n \u6c34[H2O]<\/span><\/p>\n \u6c1f\u5316\u6c22 [HF]<\/span><\/p>\n \u4e59\u7094 [C2H2]<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n \u4e00\u6c27\u5316\u78b3 [CO]<\/span><\/p>\n \u786b\u5316\u6c22 [H2S]<\/span><\/p>\n \u6c28 [NH3]<\/span><\/p>\n \u4e59\u70ef[C2H4]<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n \u4e8c\u6c27\u5316\u78b3 [CO2]<\/span><\/p>\n \u6c2f\u5316\u6c22 [HCl]<\/span><\/p>\n \u7532\u70f7[CH4]<\/span><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n \u4e00\u6c27\u5316\u78b3 + \u4e8c\u6c27\u5316\u78b3 [CO+CO2]<\/span><\/p>\n \u6c28 + \u6c34 [NH3 + H2O]<\/span><\/p>\n \u6c2f\u5316\u6c22 + \u6c34 [HCL + H2O]<\/span><\/p>\n \u6c1f\u5316\u6c22 + \u6c34 [HF + H2O]<\/span><\/p>\n <\/p>\n<\/div>\n<\/div>\n \u9ad8\u6027\u80fd<\/span><\/strong><\/p>\n <\/p>\n \u4fbf\u4e8e\u4f7f\u7528<\/span><\/strong><\/p>\n <\/p>\n \u4f4e\u62e5\u6709\u6210\u672c<\/span><\/strong><\/p>\n <\/p>\n \u754c\u9762<\/span><\/strong><\/p>\n <\/p>\n \u6b27\u6d32\u5408\u89c4\u6027<\/span><\/strong><\/p>\n <\/p>\n \u9632\u7206\u8ba4\u8bc1<\/span><\/strong><\/p>\n \u5e26\u4fdd\u62a4\u6a21\u5f0f\u76841\u533a\/21\u533aATEX\u8ba4\u8bc1\uff1a<\/span><\/p>\n II 2 GD Ex db \u64cd\u4f5c\u662f IIC T6 Gb Ex<\/span><\/p>\n Ex tb op \u4e3a IIIC T80\u00b0C Db<\/span><\/p>\n Ta = -20\u00b0C \u81f3 +60\u00b0C<\/span><\/p>\n ATEX \u8bc1\u4e66\u7f16\u53f7<\/span>CML 18 ATEX 1400X<\/span><\/strong><\/p>\n <\/p>\n SIL 2<\/strong><\/p>\n SIL 2\u00a0<\/span>[\u5f85\u5b9a]<\/span><\/strong><\/p>\n <\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n <\/p>\n TDLAS\uff08\u53ef\u8c03\u8c10\u4e8c\u6781\u7ba1\u6fc0\u5149\u5438\u6536\u5149\u8c31\uff09\u4e3b\u8981\u5229\u7528\u53ef\u8c03\u8c10\u6fc0\u5149\u5668\u7684\u7a84\u5e26\u548c\u6ce2\u957f\u968f\u7535\u6d41\u53d8\u5316\u7684\u7279\u6027\u3002\u56e0\u6b64\uff0c\u901a\u8fc7\u7cbe\u786e\u8c03\u5236\u53ef\u8c03\u8c10\u6fc0\u5149\u5668\u7684\u7535\u6d41\uff0c\u53ef\u4ee5\u626b\u63cf\u88ab\u6d4b\u6c14\u4f53\u7684\u67d0\u4e2a\u5438\u6536\u5cf0\uff08\u80cc\u666f\u6c14\u4f53\u4e0d\u5438\u6536\uff09\u3002<\/span><\/p>\n \u5728\u83b7\u5f97\u88ab\u68c0\u6d4b\u6c14\u4f53\u5438\u6536\u7684\u4e8c\u6b21\u8c10\u6ce2\u540e\uff0c\u6700\u7ec8\u5229\u7528\u8be5\u4e8c\u6b21\u8c10\u6ce2\u548c\u7ebf\u5bbd\u8ba1\u7b97\u51fa\u88ab\u68c0\u6d4b\u6c14\u4f53\u7684\u6d53\u5ea6\u3002<\/span><\/p>\n TDLAS\u6280\u672f\u5df2\u53d1\u5c55\u6210\u4e3a\u4e00\u79cd\u9ad8\u7075\u654f\u5ea6\u3001\u9ad8\u5206\u8fa8\u7387\u3001\u5feb\u901f\u54cd\u5e94\u65f6\u95f4\u548c\u9ad8\u9009\u62e9\u6027\u7684\u6c14\u4f53\u68c0\u6d4b\u6280\u672f\uff0c\u5e7f\u6cdb\u5e94\u7528\u4e8e\u5de5\u4e1a\u8fc7\u7a0b\u76d1\u6d4b\u63a7\u5236\u3002<\/span><\/p>\n \u00a0AtLAS-900\u901a\u8fc7\u4f7f\u7528\u53ef\u8c03\u8c10\u534a\u5bfc\u4f53\u6fc0\u5149\u5668\uff0c\u626b\u63cf\u88ab\u6d4b\u6c14\u4f53\uff08\u65e0\u80cc\u666f\u6c14\u4f53\uff09\u7684\u7279\u5b9a\u5438\u6536\u7ebf\uff0c\u4ee5\u83b7\u5f97\u6c14\u4f53\u7684\u4e8c\u6b21\u8c10\u6ce2\u3002\u901a\u8fc7\u5bf9\u6c14\u4f53\u7684\u4e8c\u6b21\u8c10\u6ce2\u548c\u5c55\u5bbd\u4fe1\u606f\u8fdb\u884c\u5904\u7406\u5206\u6790\uff0c\u5f97\u5230\u6c14\u4f53\u7684\u6d53\u5ea6\u3002<\/span><\/p>\n<\/div>\n <\/p>\n \n<\/div>\n<\/div>\n<\/div>\n<\/div>\n \u610f\u5927\u5229 ADEV AtLAS-900 \u2013 In Situ \u53ef\u8c03\u4e8c\u6781\u7ba1\u6fc0\u5149\u5438\u6536\u5149\u8c31\u5b66\uff08TDLAS\uff09\u5206\u6790\u4eea AtLAS-900 \u662f\u4e00\u6b3e\u9002\u7528\u4e8e\u5de5\u4e1a\u5728\u7ebf\u5e94\u7528\u7684\u6fc0\u5149\u6c14\u4f53\u5206\u6790\u4eea\uff0c\u80fd\u591f\u539f\u4f4d\uff08\u8de8\u5806 <\/p>\n","protected":false},"author":16,"featured_media":21792,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3,26,27],"tags":[19,23,29,21,25,28],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/posts\/21786"}],"collection":[{"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/comments?post=21786"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/posts\/21786\/revisions"}],"predecessor-version":[{"id":21795,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/posts\/21786\/revisions\/21795"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/media\/21792"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/media?parent=21786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/categories?post=21786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/adev\/wp-json\/wp\/v2\/tags?post=21786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\u53ef\u6d4b\u91cf\u6c14\u4f53<\/span><\/strong><\/h3>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n
\u7ec4\u5408\u7248\u672c<\/span><\/strong><\/h3>\n
\u4e3b\u8981\u7279\u70b9<\/span><\/strong><\/h3>\n
\n
\n
\n
\n
\n
\u89c4\u683c<\/strong><\/h3>\n
\n\n
\n \nPerformance Specification<\/th>\n <\/th>\n<\/tr>\n<\/thead>\n \n Optical Channel Length<\/td>\n 0.3\u2026.20 meters [note 1]<\/td>\n<\/tr>\n \n Accuracy<\/td>\n \u2264 \u00b11% FS<\/td>\n<\/tr>\n \n Linearity Error<\/td>\n \u2264 \u00b11% FS<\/td>\n<\/tr>\n \n Repeatability<\/td>\n \u2264 \u00b11% FS<\/td>\n<\/tr>\n \n Zero & Span Drift<\/td>\n \u2264 \u00b11% FS \/ 6 months<\/td>\n<\/tr>\n \n Maintenance Cycle<\/td>\n \u2264 2 times \/ year (clan optical window)<\/td>\n<\/tr>\n \n Calibration Cycle<\/td>\n \u2264 2 times \/ year<\/td>\n<\/tr>\n \n Enclosure Rating<\/td>\n IP66<\/td>\n<\/tr>\n \n Response Time<\/td>\n \u2264 1 sec. at T90<\/td>\n<\/tr>\n \n <\/td>\n <\/td>\n<\/tr>\n \n Signals<\/td>\n <\/td>\n<\/tr>\n \n Analog Output<\/td>\n 2 x 4-20 mA isolated (max. load 750 \u03a9)<\/td>\n<\/tr>\n \n Analog Input<\/td>\n 2 x 4-20 mA isolated [note 2]<\/td>\n<\/tr>\n \n Digital Output<\/td>\n RS485 \/ RS232<\/td>\n<\/tr>\n \n Relay Output<\/td>\n 3 x (24V, 1A)<\/td>\n<\/tr>\n \n <\/td>\n <\/td>\n<\/tr>\n \n Operative Specification<\/td>\n <\/td>\n<\/tr>\n \n Sample Temperature<\/td>\n 0\u00b0C\u20261300\u00b0C [note 3]<\/td>\n<\/tr>\n \n Pressure<\/td>\n Max. 3 bar abs.<\/td>\n<\/tr>\n \n Dust Content<\/td>\n \u2264 1 g\/m3 or \u2264 30 g\/m3<\/td>\n<\/tr>\n \n Water Vapor Content<\/td>\n Whichever, non-condensing<\/td>\n<\/tr>\n \n Installation<\/td>\n In situ<\/td>\n<\/tr>\n \n Process Connection<\/td>\n By soldering or with flange DN40 PN 1.6 MPa<\/td>\n<\/tr>\n \n Route Valve Flange<\/td>\n DN50 PN 1.6 MPa (standard valve)<\/td>\n<\/tr>\n \n <\/td>\n DN65 PN 1.6 MPa (gate valve for T > 300\u00b0C)<\/td>\n<\/tr>\n \n Power Supply<\/td>\n 24 Vdc or 100\u2026240 Vac, \u2264 20W<\/td>\n<\/tr>\n \n Ambient Temperature<\/td>\n -20\u00b0C\u2026.+60\u00b0C<\/td>\n<\/tr>\n \n Ambient Humidity<\/td>\n \u2264 90% non-condensing<\/td>\n<\/tr>\n \n Purge Gas<\/td>\n Nitrogen or purified instrument air [note 4]<\/td>\n<\/tr>\n \n <\/td>\n Pressure range: 0.3 MPa\u2026.0.8 MPa<\/td>\n<\/tr>\n \n <\/td>\n Flow rate: 0\u20264300 l\/h [note 5]<\/td>\n<\/tr>\n \n <\/td>\n Purging gas ports: \u00d8 8 mm<\/td>\n<\/tr>\n \n Wiring Connections<\/td>\n ATEX version: 1 x armored cable gland for cable 6.5\u00f710.5 mm. Safe area version: 1 x cable gland for cable 5\u00f78 mm<\/td>\n<\/tr>\n \n <\/td>\n 3 x threaded hole M20 x 1.5 (with plug)<\/td>\n<\/tr>\n \n <\/td>\n 1 x threaded hole M25 x 1.5 (with plug)<\/td>\n<\/tr>\n \n Physical Specification<\/td>\n <\/td>\n<\/tr>\n \n Materials Contacting Sample<\/td>\n Optical Windows: K9\/JGS2 Quartz<\/td>\n<\/tr>\n \n <\/td>\n Instrument host: 6061 \/ SS 304<\/td>\n<\/tr>\n \n <\/td>\n Flange\/tube assembly: SS 316L<\/td>\n<\/tr>\n \n <\/td>\n Root valve: SS 304<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n \n\n
\n [Note 1]
\nMinimum optical path depends on gas to be measured and range. Contact ADEV<\/td>\n<\/td>\n<\/tr>\n \n [Note 2]
\nFor eventual live compensations of temperature, pressure and O2 impurities inside purging Nitrogen, if used.<\/td>\n<\/td>\n<\/tr>\n \n [Note 3]
\nFor process temperature > 500\u00b0C water cooling system is required. Contact ADEV.<\/td>\n<\/td>\n<\/tr>\n \n [Note 4]
\nInstrument air cannot be used as purging gas in case the gas to be measured is O2 and process gas temperature is < 400\u00b0C<\/td>\n<\/td>\n<\/tr>\n \n Note 5]
\nThe precise flow rate of purging gas cannot be predetermined. It depends on several factors just like pressure and flow rate of sample gas, dust amount and type.<\/td>\n<\/td>\n<\/tr>\n \n Minimum suggested:
\n\u00b7 for pants working in positive pressure: 500 l\/h
\n\u00b7 for pants working in positive pressure: 350 l\/h<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\u5e94\u7528\u9886\u57df<\/span><\/strong><\/h3>\n