{"id":1083260,"date":"2015-07-29T18:59:48","date_gmt":"2015-07-29T02:59:48","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/?p=1083260"},"modified":"2019-03-14T16:58:30","modified_gmt":"2019-03-14T08:58:30","slug":"sr-100fr-5-radsec","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/columbia-research-laboratory\/sr-100fr-5-radsec\/","title":{"rendered":"SR-100FR (+\/- 5 Rad\/Sec"},"content":{"rendered":"

\"SR-100FR<\/p>\n

\u54e5\u4f26\u6bd4\u4e9a\u6a21\u578b\u7684SR – 100FR\u548cSR – 200RFR\u52a0\u5ea6\u7684DC\u5e94\u7528\u6c34\u5e73\u4f4e\u3002 \u4e9b\u4f20\u611f\u5668\u5305\u62ec\u6d41\u4f53\u5b50\u6982\u5ff5\u63d0\u4f9b\u6781\u7684\u7075\u654f\u5ea6\u4f4e+ \/ -0.01\u5f27\u5ea6\/\u79d22\u6ee1\u7a0b\u3002 \u6027\u529b\u77e9\u5668\u7684 <\/p>\n

\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n

The Columbia Models SR-100FR and SR-200RFR Angular Accelerometers are designed for low level near DC applications. These sensors incorporate the fluid rotor concept to provide extremely high sensitivity and full scale ranges as low as +\/-0.01 radians\/second 2 . The high performance torquer design<\/p>\n

<\/p>\n

\t\t\t\t\t\t\u6280\u672f\u53c2\u6570\/Specifications\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/p>\n\n\n\n\n\n\n\n\n\n\n\n
\t\t\t\t\t\t\t\t\t\t\tPerformance Specifications\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tAngular Acceleration\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t-5.00 to 5.00 rad\/sec\u00b2 \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tFrequency Range\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t10.00 to ? Hz \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tTechnology\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tNull-balance; Fluid Rotor \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tDevice Category\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tSensor \/ Transducer \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tSensor Mounting\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tStud\/Bolt \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tEnvironment\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Shock\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t100 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Vibration\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t10.00 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tOperating Temperature\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t-40 to 160 F \t\t\t\t\t\t\t\t\t<\/td>\n<\/table>\n

SR-100FR+-5\u62c9\u5fb7<\/strong>,\u79d2u003cSUPu003e2u003c<\/strong>,SUPu003e<\/strong>,\u54e5\u4f26\u6bd4\u4e9a\u5927\u5b66\u7814\u7a76\u5b9e\u5ba4\u516c\u53f8<\/strong>,\u52a0\u5ea6<\/strong>,SR-100FR (+\/- 5 Rad\/Sec<sup>2<\/sup>)<\/strong>, Columbia Research<\/a> Labs<\/strong>, Inc.<\/strong>, Accelerometers<\/strong><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

\u54e5\u4f26\u6bd4\u4e9a\u6a21\u578b\u7684SR – 100FR\u548cSR – 200RFR\u52a0\u5ea6\u7684DC\u5e94\u7528\u6c34\u5e73\u4f4e\u3002 \u4e9b\u4f20\u611f\u5668\u5305\u62ec\u6d41\u4f53\u5b50\u6982\u5ff5\u63d0\u4f9b\u6781\u7684\u7075\u654f\u5ea6\u4f4e+ \/ -0.01\u5f27\u5ea6\/\u79d22\u6ee1\u7a0b\u3002 <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[4],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083260"}],"collection":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/comments?post=1083260"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083260\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/media?parent=1083260"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/categories?post=1083260"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/tags?post=1083260"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}