{"id":1083362,"date":"2015-07-29T18:59:48","date_gmt":"2015-07-29T02:59:48","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/?p=1083362"},"modified":"2019-03-14T16:58:57","modified_gmt":"2019-03-14T08:58:57","slug":"7001-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/columbia-research-laboratory\/7001-2\/","title":{"rendered":"7001"},"content":{"rendered":"

\"7001<\/p>\n

\u57287001\u548c7001HT\u538b\u7535\u52a0\u5ea6\u662f\u7528\u4e8e\u7528\u51b2\u51fb\u548c\u632f\u52a8\u6d4b\u5de5\u4f5c\u7684\u597d\u62e9\u5e76\u4e14\u5c24\u5176\u5408\u5c0f\u6837\u672c\u6d4b\u7684\u7406\u60f3\u62e9\u3002 \u5b83\u4eec\u662f\u4e13\u4e3a\u4e2d\u7b49\u7387\u6d4b\u4e2d\u5c42\u6b21\u7684\u51b2\u51fb\u548c\u632f\u52a8\u3002 <\/p>\n

\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n

The Model 7001 and 7001HT Piezoelectric Accelerometers are excellent choices for general-purpose shock and vibration measurement work, and are especially well suited for testing of small specimens. They are designed for the measurement of medium frequency, moderate to high-level shock and vibration.<\/p>\n

<\/p>\n

\t\t\t\t\t\t\u6280\u672f\u53c2\u6570\/Specifications\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\t\t\t\t\t\t\t\t\t\t\tPerformance Specifications\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Acceleration \/ Shock\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t1000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tFrequency Range\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t2.00 to 5000 Hz \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tAccuracy\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t5.00 +\/-% FS \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMeasurement Axes\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\tSingle \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tDevice Type\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tSensor \/ Transducer \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tSensor Outputs\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tAcceleration \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tSensor Mounting\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tAdhesive \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tFeatures\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tEnvironmentally \/ Hermetically Sealed \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tTechnology\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tPiezoelectric \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tEnvironment\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Shock\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t1000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Vibration\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t1000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tOperating Temperature\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t-65 to 500 F \t\t\t\t\t\t\t\t\t<\/td>\n<\/table>\n

7001\u54e5\u4f26\u6bd4\u4e9a\u5927\u5b66\u7814\u7a76\u5b9e\u5ba4\u516c\u53f8<\/strong>,\u52a8\u548c\u51b2\u51fb\u4f20\u611f\u5668<\/strong>,7001<\/strong>, Columbia Research<\/a> Labs<\/strong>, Inc.<\/strong>, Shock and Impact Sensors<\/strong><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

\u57287001\u548c7001HT\u538b\u7535\u52a0\u5ea6\u662f\u7528\u4e8e\u7528\u51b2\u51fb\u548c\u632f\u52a8\u6d4b\u5de5\u4f5c\u7684\u597d\u62e9\u5e76\u4e14\u5c24\u5176\u5408\u5c0f\u6837\u672c\u6d4b\u7684\u7406\u60f3\u62e9\u3002 \u5b83\u4eec\u662f\u4e13\u4e3a\u4e2d\u7b49\u7387\u6d4b\u4e2d\u5c42\u6b21\u7684\u51b2\u51fb\u548c\u632f\u52a8\u3002 The Model 7001 and 7001H <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[4],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083362"}],"collection":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/comments?post=1083362"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083362\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/media?parent=1083362"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/categories?post=1083362"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/tags?post=1083362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}