{"id":1083384,"date":"2015-07-29T18:59:48","date_gmt":"2015-07-29T02:59:48","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/?p=1083384"},"modified":"2015-07-29T18:59:48","modified_gmt":"2015-07-29T02:59:48","slug":"612-tx","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/columbia-research-laboratory\/612-tx\/","title":{"rendered":"612-TX"},"content":{"rendered":"

\"612-TX<\/p>\n

\u578b\u53f7612 – TX\u7684\u4e09\u538b\u7535\u52a0\u5ea6\u7684\u53ef\u6ee1\u6700\u4e25\u683c\u7684\u7a7a\u548c\u52a0\u53ea\u67098\u514b\u7684\u548c\u4f53\u79ef\u76840.082\u7acb\u65b9\u5bf8\u6c42\u3002 <\/p>\n

\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n

The Model 612-TX Triaxial Piezoelectric Accelerometer is designed to meet the most stringent space and mass loading requirements with a weight of only 8 grams and a volume of 0.082 cubic inches.<\/p>\n

<\/p>\n

\t\t\t\t\t\t\u6280\u672f\u53c2\u6570\/Specifications\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/p>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
\t\t\t\t\t\t\t\t\t\t\tPerformance Specifications\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tAcceleration\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t1000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tFrequency Range\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t2.00 to 8000 Hz \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tAccuracy\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t5.00 +\/-% FS \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tMeasurement Axes\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tTriaxial \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tDevice Category\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tSensor \/ Transducer \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tSensor Outputs\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tAcceleration \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tSensor Mounting\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tAdhesive \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tTechnology\t\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t\tPiezoelectric \t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\t\tEnvironment\t\t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Shock\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t5000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tMaximum Vibration\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t1000 g \t\t\t\t\t\t\t\t\t<\/td>\n
\t\t\t\t\t\t\t\t\t\tOperating Temperature\t\t\t\t\t\t\t\t\t<\/td>\n\t\t\t\t\t\t\t\t\t\t-100 to 500 F \t\t\t\t\t\t\t\t\t<\/td>\n<\/table>\n

612-TX<\/strong>,\u54e5\u4f26\u6bd4\u4e9a\u5927\u5b66\u7684\u7814\u7a76\u5b9e\u5ba4\u516c\u53f8<\/strong>,\u632f\u52a8\u4f20\u611f\u5668<\/a><\/strong>,612-TX<\/strong>, Columbia Research<\/a> Labs<\/strong>, Inc.<\/strong>, Vibration Sensors<\/strong><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

\u578b\u53f7612 – TX\u7684\u4e09\u538b\u7535\u52a0\u5ea6\u7684\u53ef\u6ee1\u6700\u4e25\u683c\u7684\u7a7a\u548c\u52a0\u53ea\u67098\u514b\u7684\u548c\u4f53\u79ef\u76840.082\u7acb\u65b9\u5bf8\u6c42\u3002 The Model 612-TX Triaxial Piezoelectri <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083384"}],"collection":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/comments?post=1083384"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/posts\/1083384\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/media?parent=1083384"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/categories?post=1083384"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/columbia-research-laboratory\/wp-json\/wp\/v2\/tags?post=1083384"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}