{"id":87,"date":"2019-01-11T14:30:17","date_gmt":"2019-01-11T06:30:17","guid":{"rendered":"https:\/\/www.bihec.com\/equilibar\/?p=87"},"modified":"2019-01-11T14:30:25","modified_gmt":"2019-01-11T06:30:25","slug":"electronic-vacuum-regulators-%e7%94%b5%e5%ad%90%e7%9c%9f%e7%a9%ba%e8%b0%83%e8%8a%82%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/equilibar\/electronic-vacuum-regulators-%e7%94%b5%e5%ad%90%e7%9c%9f%e7%a9%ba%e8%b0%83%e8%8a%82%e5%99%a8\/","title":{"rendered":"Electronic Vacuum Regulators \u7535\u5b50\u771f\u7a7a\u8c03\u8282\u5668"},"content":{"rendered":"

\"image<\/p>\n

Electronic Vacuum Regulator<\/strong>
\nAnodized Aluminum EVR-GSD8 with integrated QPV electronic pilot regulator<\/p>\n

<\/p>\n

Equilibar electronic vacuum regulators allow vacuum control through a computerized command signal. The command signal is first sent to a small electronic regulator that produces a pilot signal to the reference port of the dome-loaded Equilibar Vacuum Regulator (EVR) to control the process pressure.<\/p>\n

equilibar \u7535\u5b50\u771f\u7a7a\u8c03\u8282\u5668<\/a>\u5141\u8bb8\u901a\u8fc7\u8ba1\u7b97\u673a\u5316\u7684\u547d\u4ee4\u4fe1\u53f7\u8fdb\u884c\u771f\u7a7a\u63a7\u5236<\/a>\u3002\u547d\u4ee4\u4fe1\u53f7\u9996\u5148\u88ab\u53d1\u9001\u5230\u4e00\u4e2a\u5c0f\u578b\u7535\u5b50\u8c03\u8282\u5668<\/a>, \u8be5\u8c03\u8282\u5668\u4ea7\u751f\u4e00\u4e2a\u5bfc\u9891\u4fe1\u53f7, \u8fdb\u5165\u8d1f\u8f7d\u8d64\u9053\u771f\u7a7a\u8c03\u8282\u5668<\/a> (evr) \u7684\u53c2\u8003\u7aef\u53e3, \u4ee5\u63a7\u5236\u8fc7\u7a0b\u538b\u529b\u3002
\nequilibar \u63d0\u4f9b\u4e00\u7cfb\u5217\u7cbe\u5bc6
\u7535\u5b50\u538b\u529b\u8c03\u8282\u5668<\/a>, \u4ee5\u63d0\u4f9b\u6b64\u8bd5\u70b9\u53c2\u8003\u4fe1\u53f7\u3002qpv \u8d85\u5206\u8fa8\u7387\u548c epr-30hg \u6a21\u578b\u51e0\u4e4e\u6ca1\u6709\u6ede\u540e\u6027\u6216\u6b7b\u5e26, \u4ece\u800c\u80fd\u591f\u8fdb\u884c\u7cbe\u786e\u8c03\u6574\u3002<\/p>\n

Equilibar offers a line of precision electronic pressure regulators to provide this pilot reference signal. The QPV ultra-resolution and the EPR-30Hg models have virtually no hysteresis or deadband, resulting in the capability to make precise adjustments.\u00a0equilibar \u63d0\u4f9b\u4e00\u7cfb\u5217\u7cbe\u5bc6\u7535\u5b50\u538b\u529b\u8c03\u8282\u5668<\/a>, \u4ee5\u63d0\u4f9b\u6b64\u8bd5\u70b9\u53c2\u8003\u4fe1\u53f7\u3002qpv \u8d85\u5206\u8fa8\u7387\u548c epr-30hg \u6a21\u578b\u51e0\u4e4e\u6ca1\u6709\u6ede\u540e\u6027\u6216\u6b7b\u5e26, \u4ece\u800c\u80fd\u591f\u8fdb\u884c\u7cbe\u786e\u8c03\u6574\u3002<\/p>\n

These regulators can be used in open loop mode or closed loop mode. In open loop mode, the vacuum setpoint is commanded using a computerized signal sent to the electronic pilot regulator. The pilot regulator produces that commanded pressure onto the EVR reference port to keep the process vacuum very close to the setpoint value. Open loop mode will result in a slight variability in vacuum pressure as flow rates increase.\u00a0\u8fd9\u4e9b\u8c03\u8282\u5668\u53ef\u5728\u5f00\u73af\u6a21\u5f0f\u6216\u95ed\u73af\u6a21\u5f0f\u4e0b\u4f7f\u7528\u3002\u5728\u5f00\u73af\u6a21\u5f0f\u4e0b, \u771f\u7a7a\u8bbe\u5b9a\u503c\u4f7f\u7528\u53d1\u9001\u5230\u7535\u5b50\u5148\u5bfc\u8c03\u8282\u5668\u7684\u8ba1\u7b97\u673a\u4fe1\u53f7\u8fdb\u884c\u547d\u4ee4\u3002\u5148\u5bfc\u8c03\u8282\u5668\u5728 evr \u53c2\u8003\u7aef\u53e3\u4e0a\u4ea7\u751f\u6240\u547d\u4ee4\u7684\u538b\u529b, \u4ee5\u4f7f\u5de5\u827a\u771f\u7a7a\u975e\u5e38\u63a5\u8fd1\u8bbe\u5b9a\u503c\u3002\u5f00\u73af\u6a21\u5f0f\u5c06\u5bfc\u81f4\u771f\u7a7a\u538b\u529b\u7684\u8f7b\u5fae\u53d8\u5316, \u968f\u7740\u6d41\u91cf\u7684\u589e\u52a0\u3002<\/p>\n

In closed loop, or PID mode, the process vacuum pressure is monitored by a separate pressure sensor close to the process, and the command signal sent to the pilot regulator is adjusted to bring that process pressure to match the desired setpoint. This PID action can be accomplished inside the QPV electronic pressure regulator, or in the existing process control system. Closed loop control will result in more accuracy over a wide range of flow rates.\u00a0\u5728\u95ed\u73af\u6216 pid \u6a21\u5f0f\u4e0b, \u8fc7\u7a0b\u771f\u7a7a\u538b\u529b\u7531\u63a5\u8fd1\u8fc7\u7a0b\u7684\u5355\u72ec\u538b\u529b\u4f20\u611f\u5668\u8fdb\u884c\u76d1\u6d4b, \u5e76\u8c03\u6574\u53d1\u9001\u5230\u5148\u5bfc\u8c03\u8282\u5668\u7684\u547d\u4ee4\u4fe1\u53f7, \u4f7f\u8be5\u8fc7\u7a0b\u538b\u529b\u4e0e\u6240\u9700\u7684\u8bbe\u5b9a\u503c\u76f8\u5339\u914d\u3002\u8fd9\u79cd pid \u52a8\u4f5c\u53ef\u4ee5\u5728 qpv \u7535\u5b50\u538b\u529b\u8c03\u8282\u5668\u5185\u5b8c\u6210, \u4e5f\u53ef\u4ee5\u5728\u73b0\u6709\u7684\u8fc7\u7a0b\u63a7\u5236\u7cfb\u7edf\u4e2d\u5b8c\u6210\u3002\u95ed\u73af\u63a7\u5236\u5c06\u5728\u5e7f\u6cdb\u7684\u6d41\u91cf\u8303\u56f4\u5185\u5b9e\u73b0\u66f4\u9ad8\u7684\u7cbe\u5ea6\u3002<\/p>\n

Electronic Vacuum Regulator Details<\/h4>\n

This table details Equilibar Vacuum Regulators with inlet port sizes from 1\/4\u2033 to 1\u2033.<\/p>\n\n\n\n\n\n\n\n\n\n\n
Model<\/th>\nInlet\/Outlet Port<\/th>\nReference Port<\/th>\nStandard Body Materials<\/th>\nDiameter<\/th>\nHeight<\/th>\nCv Range (precision)<\/th>\nAvailable End Fittings<\/th>\n<\/tr>\n
(inch)<\/td>\nMin<\/td>\nMax<\/td>\nStd<\/td>\nAvailable<\/td>\n<\/tr>\n<\/thead>\n
EVR-GSD2<\/td>\n\u00bc\u201d<\/td>\n1\/8\u2033<\/td>\nSS316 (std) Anodized Aluminum
\nPVC<\/td>\n
3.0<\/td>\n1.3<\/td>\n1E-3<\/td>\n1.0<\/td>\nNPT<\/td>\n150# Flange BSP SAE VCO style VCR style<\/td>\n<\/tr>\n
EVR-GSD3<\/td>\n3\/8\u2033<\/td>\n3.5<\/td>\n1.35<\/td>\n1E-3<\/td>\n1.8<\/td>\n<\/tr>\n
EVR-GSD4<\/td>\n\u00bd\u201d<\/td>\n4.5<\/td>\n1.6<\/td>\n1E-2<\/td>\n3.2<\/td>\n<\/tr>\n
EVR-GSD6<\/td>\n3\/4\u2033<\/td>\n6.0<\/td>\n2.0<\/td>\n1E-2<\/td>\n5.5<\/td>\n<\/tr>\n
EVR-GSD8<\/td>\n1\u2033<\/td>\n7.0<\/td>\n2.6<\/td>\n1E-2<\/td>\n8.5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
<\/div>","protected":false},"excerpt":{"rendered":"

Electronic Vacuum Regulator Anodized Aluminum EVR-GSD8 with integrated QPV electronic pilo <\/p>\n","protected":false},"author":18,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[4],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/posts\/87"}],"collection":[{"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/comments?post=87"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/posts\/87\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/media?parent=87"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/categories?post=87"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/equilibar\/wp-json\/wp\/v2\/tags?post=87"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}