{"id":356,"date":"2022-06-10T11:18:06","date_gmt":"2022-06-10T03:18:06","guid":{"rendered":"https:\/\/www.bihec.com\/erdco\/?p=356"},"modified":"2022-06-10T11:18:06","modified_gmt":"2022-06-10T03:18:06","slug":"%e7%be%8e%e5%9b%bderdco-%e9%97%aa%e7%82%b9%e4%bb%aa-rapid-tester-rt-00001","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/erdco\/%e7%be%8e%e5%9b%bderdco-%e9%97%aa%e7%82%b9%e4%bb%aa-rapid-tester-rt-00001\/","title":{"rendered":"\u7f8e\u56fdERDCO-\u95ea\u70b9\u4eea Rapid Tester\u00ae RT-00001"},"content":{"rendered":"

Rapid Tester<\/a>\u00ae<\/sup> RT-00001<\/a>\u95ea\u70b9\u4eea<\/a><\/h1>\n

\"\"<\/p>\n

\u5e94\u7528\uff1a<\/h2>\n

\u8d28\u91cf\u4fdd\u8bc1<\/span><\/strong>\u2014\u2014\u9a8c\u8bc1\u542b\u6709\u6613\u71c3\u6210\u5206\u7684\u6db2\u4f53\u4ea7\u54c1\u7684\u914d\u65b9\u3002<\/span><\/p>\n

\u5408\u89c4\u6027\u6d4b\u8bd5<\/span><\/strong>\u2014\u2014\u76d1\u7ba1\u673a\u6784\u901a\u5e38\u8981\u6c42\u5728\u8fd0\u8f93\u6216\u5904\u7f6e\u6db2\u4f53\u4e4b\u524d\u8fdb\u884c\u3002<\/span><\/p>\n

\u71c3\u6cb9\u7a00\u91ca<\/span><\/strong>\u2014\u2014\u786e\u5b9a\u53d1\u52a8\u673a\u66f2\u8f74\u7bb1\u6cb9\u4e2d\u71c3\u6cb9\u7684\u76f8\u5bf9\u767e\u5206\u6bd4\uff0c\u4ee5\u9884\u6d4b\u53d1\u52a8\u673a\u6539\u9020\u7684\u9700\u8981\u3002<\/span><\/p>\n

<\/h3>\n

\u5feb\u901f\u6d4b\u8bd5-\u5c0f\u6837\u672c<\/span><\/h3>\n

\u5bf9\u4e8e\u95ea\u70b9\u4f4e\u4e8e 100\u00b0C (212\u00b0F) \u7684 2 ml \u6837\u54c1\uff0c\u6d4b\u8bd5\u65f6\u95f4\u4ec5\u4e3a\u4e00\u5206\u949f\u3002\u60a8\u53ef\u4ee5\u4f7f\u7528 Rapid Tester\u00a0<\/span>\u00ae<\/span><\/sup>\u00a0<\/span>\u8fd0\u884c 10 \u6b21\u6d4b\u8bd5\uff0c\u800c\u7528\u5176\u4ed6\u65b9\u6cd5\u4ec5\u6267\u884c\u4e00\u9879\u6240\u9700\u7684\u65f6\u95f4\u30022 ml\/4 ml \u6837\u54c1\u662f\u5176\u4ed6\u95ea\u70b9\u65b9\u6cd5\u6240\u9700\u7684\u5927\u6837\u54c1\u7684\u4e00\u5c0f\u90e8\u5206\u3002\u8fd9\u51cf\u5c11\u4e86\u91c7\u6837\u548c\u5904\u7f6e\u95ee\u9898\uff0c\u540c\u65f6\u63d0\u9ad8\u4e86\u5b89\u5168\u6027\u3002\u6570\u5b57\u7535\u8def\u5141\u8bb8\u5bf9\u6d4b\u8bd5\u6e29\u5ea6\u8fdb\u884c\u7b80\u5355\u8c03\u6574\u548c\u7cbe\u786e\u81ea\u52a8\u8c03\u8282\u3002\u5728\u65cb\u8f6c\u6e29\u5ea6\u63a7\u5236\u65cb\u94ae\u7684\u540c\u65f6\u6309\u4e0b\u9884\u8bbe\u5f00\u5173\uff0c\u76f4\u5230\u663e\u793a\u76ee\u6807\u6e29\u5ea6\u3002\u6d4b\u8bd5\u676f\u6e29\u5ea6\u81ea\u52a8\u663e\u793a\u5728 LCD \u663e\u793a\u5c4f\u4e0a\u3002<\/span><\/p>\n

 <\/p>\n

Rapid Tester\u00a0<\/span>\u00ae<\/span><\/span>\u662f\u4e00\u79cd\u534a\u81ea\u52a8\u4eea\u5668\uff0c\u7528\u4e8e\u786e\u5b9a\u6613\u71c3\u6db2\u4f53\u7684\u95ea\u70b9\u6e29\u5ea6\/\u53ef\u71c3\u6027\u3002\u4ece\u73af\u5883\u6e29\u5ea6\u5230 572\u00b0F (300\u00b0C) \u7684\u95ed\u676f\u6d4b\u8bd5\u6e29\u5ea6\u7531\u6570\u5b57\u9884\u8bbe\u76ee\u6807\u6e29\u5ea6\u7535\u8def\u81ea\u52a8\u63a7\u5236\u3002\u96c6\u6210 LCD \u663e\u793a\u5c4f\u3001NIST \u53ef\u6eaf\u6e90\u6e29\u5ea6\u8ba1\u3001\u4e00\u6b21\u6027\u6cb9\u7bb1\u548c\u7535\u5b50\u8ba1\u65f6\u5668\u662f\u6807\u51c6\u914d\u7f6e\u3002<\/span><\/p>\n

\u89c4\u683c\uff1a<\/h2>\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n
\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
ASTM D 3278<\/td>\n\u201cFlash Point of Liquids by Small Scale Closed Cup Apparatus\u201d<\/td>\n<\/tr>\n
ASTM D 3828<\/td>\n\u201cFlash Point by Small Scale Closed Tester\u201d<\/td>\n<\/tr>\n
ASTM D 4206<\/td>\n\u201cSustained Burning of Liquid Mixtures Using the Small Scale Open-Cup Apparatus\u201d<\/td>\n<\/tr>\n
BS 3900 Part A11<\/td>\n\u201cSmall Scale Test for Combustibility\u201d<\/td>\n<\/tr>\n
BS 3900 Part A13<\/td>\n\u201cRapid Test for Flash Point – Danger
\nClassification\u201d<\/td>\n<\/tr>\n
BS 3900 Part A14<\/td>\n\u201cRapid Tests for Flash Point – Paints
\nand Varnishes\u201d<\/td>\n<\/tr>\n
CPSC CFR 16-1500.43a<\/td>\n\u201cFederal Hazardous Substances
\nAct Regulations\u201d<\/td>\n<\/tr>\n
DOT CFR 49-173.115<\/td>\n\u201cFlammable, Combustible, and
\nPyrophoric liquids, definitions\u201d<\/td>\n<\/tr>\n
IATA Resolution 618<\/td>\nSection 3.3.4 and 3.3.5<\/td>\n<\/tr>\n
Attachment A<\/td>\n<\/td>\n<\/tr>\n
IP 303<\/td>\nFlash Point by Closed Rapid Tester\u201d<\/td>\n<\/tr>\n
ISO 3679<\/td>\n\u201cPaints, Varnishes, Petroleum and
\nRelated Products – Determination of
\nFlash Point – Rapid Equilibrium
\nMethod\u201d<\/td>\n<\/tr>\n
ISO 3680<\/td>\n\u201cPaints, Varnishes, Petroleum and
\nRelated Products – Flash\/No Flash
\nTest – Rapid Equilibrium Method\u201d<\/td>\n<\/tr>\n
OSHA 29CFR 1910-106<\/td>\n\u201cProgram Directive 100\u201d<\/td>\n<\/tr>\n