{"id":219678,"date":"2016-02-01T03:11:34","date_gmt":"2016-01-31T19:11:34","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/?p=219678"},"modified":"2019-03-19T14:45:17","modified_gmt":"2019-03-19T06:45:17","slug":"flow-calibrator-max-150-psig","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/flow-systems\/flow-calibrator-max-150-psig\/","title":{"rendered":"Flow calibrator max. 150 psig"},"content":{"rendered":"

Flow calibrator max. 150 psig \u6d41\u91cf\u6821\u51c6\u4eea\u6700\u5927150 psig
Flow calibrator max. 150 psig \u6d41\u91cf\u6821\u51c6\u4eea\u6700\u5927150 psig<\/p>\n

Characteristics
\u7279\u70b9
Measured physical value:
\u5b9e\u6d4b\u7269\u7406\u503c\uff1a
flow
\u6d41
Description
\u63cf\u8ff0
The Gas Flow Calibrator is a piston-prover-based test stand utilizing sonic nozzles to provide metrology for all gas metering technologies. This system:
\u6c14\u4f53\u6d41\u91cf\u6821\u51c6\u4eea\u662f\u4e00\u79cd\u57fa\u4e8e\u8bd5\u9a8c\u6d3b\u585e\u88c5\u7f6e\u7ad9\u5229\u7528\u97f3\u901f\u55b7\u5634\u63d0\u4f9b\u6240\u6709\u5929\u7136\u6c14\u8ba1\u91cf\u6280\u672f\u8ba1\u91cf\u3002\u672c\u7cfb\u7edf\uff1a
calibrates flow meters at pressures ranging from atmospheric to 150 psig
\u6821\u51c6\u6d41\u91cf\u8ba1\u538b\u529b\u8303\u56f4\u4ece\u5927\u6c14\u5230150 psig
tests flow meters both at atmospheric and elevated pressures
\u5728\u5927\u6c14\u548c\u538b\u529b\u4e0b\u6d4b\u8bd5\u6d41\u91cf\u8868
supports a wide variety of meter types (listed below)
\u652f\u6301\u591a\u79cd\u7c7b\u578b\u7684\u8868\u7c7b\u578b\uff08\u4e0b\u9762\u5217\u51fa\uff09
does not require tight environmental temperature control
\u4e0d\u9700\u8981\u4e25\u683c\u7684\u73af\u5883\u6e29\u5ea6\u63a7\u5236
supports common calibration gasses
\u652f\u6301\u901a\u7528\u7684\u6821\u51c6\u6c14\u4f53
Key Features
\u4e3b\u8981\u7279\u70b9
Scaleable expansion in mass flow and accuracy
\u5728\u6d41\u91cf\u548c\u7cbe\u5ea6\u53ef\u6269\u5c55
No constraints on test-section diameter or length
\u8bd5\u9a8c\u6bb5\u76f4\u5f84\u6216\u957f\u5ea6\u65e0\u9650\u5236
Scaleable range and accuracy utilizing a single system controller
\u53ef\u6269\u5c55\u7684\u8303\u56f4\uff0c\u5229\u7528\u4e00\u4e2a\u5355\u4e00\u7684\u7cfb\u7edf\u63a7\u5236\u7cbe\u5ea6
No oils or hazardous materials (Mercury) required
\u65e0\u6cb9\u6216\u6709\u5bb3\u7269\u8d28\uff08\u6c5e\uff09\u8981\u6c42
Total automation with closed loop control
\u5168\u81ea\u52a8\u95ed\u73af\u63a7\u5236<\/p>\n

Flow calibrator max. 150 psig \u6d41\u91cf\u6821\u51c6\u4eea\u6700\u5927150 psig<\/strong><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

Flow calibrator max. 150 psig \u6d41\u91cf\u6821\u51c6\u4eea\u6700\u5927150 psig Characteristics\u7279\u70b9Measured physical value:\u5b9e\u6d4b\u7269 <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[32],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/posts\/219678"}],"collection":[{"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/comments?post=219678"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/posts\/219678\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/media?parent=219678"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/categories?post=219678"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/flow-systems\/wp-json\/wp\/v2\/tags?post=219678"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}