{"id":227,"date":"2023-12-11T13:54:24","date_gmt":"2023-12-11T05:54:24","guid":{"rendered":"https:\/\/www.bihec.com\/gms-hydraulic-components-industry-trade-ltd\/?p=227"},"modified":"2023-12-11T13:54:24","modified_gmt":"2023-12-11T05:54:24","slug":"%e5%9c%9f%e8%80%b3%e5%85%b6gms-hydraulic-%e6%af%94%e4%be%8b%e9%98%80-%e7%94%b5%e6%b6%b2%e6%af%94%e4%be%8b%e9%98%80-%e6%b6%b2%e5%8e%8b%e9%98%80-%e6%af%94%e4%be%8b%e9%98%80-gpv-130","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/gms-hydraulic-components-industry-trade-ltd\/%e5%9c%9f%e8%80%b3%e5%85%b6gms-hydraulic-%e6%af%94%e4%be%8b%e9%98%80-%e7%94%b5%e6%b6%b2%e6%af%94%e4%be%8b%e9%98%80-%e6%b6%b2%e5%8e%8b%e9%98%80-%e6%af%94%e4%be%8b%e9%98%80-gpv-130\/","title":{"rendered":"\u571f\u8033\u5176GMS HYDRAULIC. \u6bd4\u4f8b\u9600 \u7535\u6db2\u6bd4\u4f8b\u9600 \u6db2\u538b\u9600 \u6bd4\u4f8b\u9600 GPV 130"},"content":{"rendered":"
\u6bd4\u4f8b\u9600<\/a>\u4e0e\u4f20\u7edf\u7535\u8def\u4e0d\u540c\uff0c\u8d1f\u8f7d\u611f\u5e94\u4e2d\u6267\u884c\u5668\u4e0a\u7684\u538b\u529b\u4fe1\u53f7\u4e0d\u65ad\u63a5\u6536\uff0c\u5e76\u7528\u4f5c\u5206\u914d\u5668\u548c\u6cf5\u63a7\u5236\u7684\u5148\u5bfc\u53c2\u8003\u70b9\u3002<\/span><\/p>\n \u56e0\u6b64\uff0c\u4e0e\u4f20\u7edf\u7684\u56de\u8def\u76f8\u6bd4\uff0c\u6db2\u538b\u7cfb\u7edf\u6709\u6548\u5730\u5de5\u4f5c\u5e76\u4e14\u6bcf\u4e2a\u5de5\u4f5c\u90e8\u5206\u6d88\u8017\u8db3\u591f\u7684\u80fd\u91cf\u3002<\/span>\u8d1f\u8f7d\u611f\u5e94\u6bd4\u4f8b\u65b9\u5411\u63a7\u5236\u9600\u7531\u7535\u5b50\u9a6c\u8fbe\u9a71\u52a8\uff0c\u53ef\u4ee5\u8d85\u7cbe\u7ec6\u5730\u9a71\u52a8\u6ed1\u9600\u3002<\/span>GPV\u6bd4\u4f8b\u65b9\u5411\u63a7\u5236\u9600\u4f7f\u8fd0\u52a8\u7684\u5e94\u7528\u66f4\u52a0\u5e73\u7a33\u53ef\u9760\u3002<\/span><\/p>\n \u672c\u4ea7\u54c1\u663e\u793a\u4e86\u572840\u00b0C-104\u00b0F\u6e29\u5ea6\u4e0b\u901a\u8fc7\u7c98\u5ea6\u4e3a46 mm2\/s\u201346 cSt\u7684\u77ff\u7269\u6cb9\u6d4b\u91cf\u7684\u6280\u672f\u89c4\u8303\u548c\u56fe\u8868\u3002<\/p>\n <\/p>\n \u6bd4\u4f8b\u9600GPV 130<\/a>\u4e3b\u8981\u7279\u70b9<\/strong><\/p>\n \u5e73\u7a33\u53ef\u9760<\/p>\n \u7cbe\u7ec6\u5ea6\u9ad8<\/p>\n \u6297\u6c61\u67d3\u6027\u80fd\u5f3a<\/p>\n \u7535\u4fe1\u53f7\u4fbf\u4e8e\u4f20\u9012\uff0c\u80fd\u7b80\u5355\u5730\u5b9e\u73b0\u8fdc\u8ddd\u79bb\u63a7\u5236<\/p>\n \u6bd4\u4f8b\u9600GPV 130\u4e3b\u8981\u5e94\u7528<\/strong><\/p>\n \u6316\u6398\u673a<\/p>\n \u524d\u7f6e\u88c5\u8f7d\u673a<\/p>\n \u8d77\u91cd\u673a<\/p>\n \u53cd\u94f2\u88c5\u8f7d\u673a<\/p>\n \u9700\u8981\u6bd4\u4f8b\u63a7\u5236\u7684\u8239\u8236<\/p>\n <\/p>\n \u6bd4\u4f8b\u9600GPV 130\u4ea7\u54c1\u6280\u672f\u53c2\u6570<\/strong><\/p>\n <\/td>\n <\/td>\n (inlet temperature)<\/td>\n <\/td>\n <\/p>\n \u6bd4\u4f8b\u9600\u4e0e\u4f20\u7edf\u7535\u8def\u4e0d\u540c\uff0c\u8d1f\u8f7d\u611f\u5e94\u4e2d\u6267\u884c\u5668\u4e0a\u7684\u538b\u529b\u4fe1\u53f7\u4e0d\u65ad\u63a5\u6536\uff0c\u5e76\u7528\u4f5c\u5206\u914d\u5668\u548c\u6cf5\u63a7\u5236\u7684\u5148\u5bfc\u53c2\u8003\u70b9\u3002 \u56e0\u6b64\uff0c\u4e0e\u4f20\u7edf\u7684\u56de\u8def\u76f8\u6bd4\uff0c\u6db2\u538b\u7cfb\u7edf\u6709\u6548\u5730\u5de5\u4f5c\u5e76\u4e14\u6bcf\u4e2a\u5de5\u4f5c\u90e8\u5206\u6d88\u8017\u8db3\u591f\u7684\u80fd\u91cf\u3002\u8d1f\u8f7d\u611f\u5e94\u6bd4 <\/p>\n","protected":false},"author":32,"featured_media":231,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[7,32,6,4,11,3,5,31,30],"yoast_head":"\n\n\n
\n Max. pressure<\/p>\n Port P continuous\u00a01)<\/sup><\/td>\n 350 bar<\/td>\n [5075 psi]<\/td>\n<\/tr>\n \n Port P intermittent\u00a05)<\/sup><\/td>\n 400 bar<\/td>\n [5800 psi]<\/td>\n<\/tr>\n \n Port A\/B continuous<\/td>\n 350 bar<\/td>\n [5075 psi]<\/td>\n<\/tr>\n \n Port A\/B intermittent<\/td>\n 420 bar<\/td>\n [6090 psi]<\/td>\n<\/tr>\n \n Port T, static\/dynamic<\/td>\n 25\/40 bar<\/td>\n [365\/580 psi]<\/td>\n<\/tr>\n \n Oil flow rated<\/td>\n Port P\u00a03) 4)<\/sup><\/td>\n 140\/230 l\/min.<\/td>\n [37\/61 US gal\/min]<\/td>\n<\/tr>\n \n Port A\/B, with press. comp.2)<\/sup><\/td>\n 100 l\/min.<\/td>\n [26.4 US gal\/min]<\/td>\n<\/tr>\n \n Port A\/B, without press. comp.<\/td>\n 130 l\/min.<\/td>\n [34 US gal\/min]<\/td>\n<\/tr>\n \n Spool travel, standard<\/td>\n \u00b1 7 mm<\/td>\n [\u00b10.28 in]<\/td>\n<\/tr>\n \n Spool travel, float position<\/td>\n Proportional range<\/td>\n \u00b1 4.8 mm<\/td>\n [\u00b10.19 in]<\/td>\n<\/tr>\n \n Float position<\/td>\n \u00b1 8 mm<\/td>\n [\u00b10.32 in]<\/td>\n<\/tr>\n \n Dead band, flow control spools<\/td>\n Standard<\/td>\n \u00b1 1.5 mm<\/td>\n [\u00b10.06 in]<\/td>\n<\/tr>\n \n Linear characteristic<\/td>\n \u00b1 0.8 mm<\/td>\n [\u00b10.03 in]<\/td>\n<\/tr>\n \n Max. internal leakage at 100 bar [1450 psi] and 21mm2<\/sup>\/s[102 SUS]<\/p>\n A\/B \u00ae T without shock valve<\/td>\n 20 cm3<\/sup>\/min.<\/td>\n [1.85 in3<\/sup>\/min]<\/td>\n<\/tr>\n \n A\/B \u00ae T with shock valve<\/td>\n 25 cm3<\/sup>\/min.<\/td>\n [2.15 in3<\/sup>\/min]<\/td>\n<\/tr>\n \n Oil temperature<\/p>\n Recommended temperature<\/td>\n 30 \u00ae 60 \u00b0C<\/td>\n [86 \u00ae 140 \u00b0F]<\/td>\n<\/tr>\n \n Min. temperature<\/td>\n -30 \u00b0C<\/td>\n [-22 \u00b0F]<\/td>\n<\/tr>\n \n Max. temperature<\/td>\n +90 \u00b0C<\/td>\n [194 \u00b0F]<\/td>\n<\/tr>\n \n Ambient temperature<\/td>\n -30 \u00ae 60 \u00b0C<\/td>\n [-22 \u00ae 140 \u00b0F]<\/td>\n<\/tr>\n \n Oil viscosity<\/p>\n Operating range<\/td>\n 12 – 75 mm2<\/sup>\/s<\/td>\n [65 – 347 SUS]<\/td>\n<\/tr>\n \n Min. viscosity<\/td>\n 4 mm2<\/sup>\/s<\/td>\n [39 SUS]<\/td>\n<\/tr>\n \n Max. viscosity<\/td>\n 460 mm2<\/sup>\/s<\/td>\n [2128 SUS]<\/td>\n<\/tr>\n \n Filtration (See chapter Filtration)<\/td>\n Max. contamination(ISO 4406)<\/td>\n 23\/19\/16<\/td>\n 23\/19\/16<\/td>\n<\/tr>\n \n Oil consumption in pilot oil pressure reduction valve<\/td>\n 5 l\/min.<\/td>\n [0.13 US gal\/min]<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n