{"id":154,"date":"2024-01-31T11:54:26","date_gmt":"2024-01-31T03:54:26","guid":{"rendered":"https:\/\/www.bihec.com\/industrial-magnetics\/?p=154"},"modified":"2024-01-31T11:04:35","modified_gmt":"2024-01-31T03:04:35","slug":"%e7%be%8e%e5%9b%bdindustrial-magnetics%e7%9f%a9%e5%bd%a2%e5%b9%b3%e8%a1%8c%e6%9e%81%e7%94%b5%e7%a3%81%e9%93%81industrial-magnetics-ep2-121","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/industrial-magnetics\/%e7%be%8e%e5%9b%bdindustrial-magnetics%e7%9f%a9%e5%bd%a2%e5%b9%b3%e8%a1%8c%e6%9e%81%e7%94%b5%e7%a3%81%e9%93%81industrial-magnetics-ep2-121\/","title":{"rendered":"\u7f8e\u56fdIndustrial Magnetics\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1,Industrial Magnetics EP2-121,EP2-131,EP2-141,EP2-242,Industrial Magnetics\u78c1\u94c1"},"content":{"rendered":"

\u7f8e\u56fdIndustrial Magnetics\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1<\/a>,Industrial Magnetics EP2-121<\/a>,EP2-131,EP2-141,EP2-242,Industrial Magnetics<\/a>\u78c1\u94c1<\/h4>\n

Industrial Magnetics,Inc\u63d0\u4f9b\u8bb8\u591a\u73b0\u6210\u7684\u5de5\u4e1a\u78c1\u4f53\u4ea7\u54c1<\/a>\uff0c\u4f46\u6b63\u662fIndustrial Magnetics\u80fd\u591f\u4e3a\u5ba2\u6237\u63d0\u4f9b\u9488\u5bf9\u7279\u5b9a\u95ee\u9898\u7684\u89e3\u51b3\u65b9\u6848\uff0c\u8fd9\u4f7fIndustrial Magnetics\u4e0e\u4e1a\u5185\u5176\u4ed6\u516c\u53f8\u4e0d\u540c\u3002Industrial Magnetics\u4e3a\u80fd\u591f\u5728\u4e0d\u727a\u7272\u8d28\u91cf\u7684\u60c5\u51b5\u4e0b\u5feb\u901f\u63d0\u4f9b\u6ee1\u8db3\u5ba2\u6237\u8981\u6c42\u7684\u6700\u4f73\u78c1\u6027\u89e3\u51b3\u65b9\u6848\u800c\u611f\u5230\u81ea\u8c6a\u3002<\/p>\n

\u901a\u8fc7\u76f4\u9500\u56e2\u961f\u548c\u6e20\u9053\u5408\u4f5c\u4f19\u4f34\u7684\u7ec4\u5408\uff0cIndustrial Magnetics\u5728\u5168\u7403\u8303\u56f4\u5185\u8fdb\u884c\u5206\u9500\uff0c\u52aa\u529b\u63d0\u4f9b\u4e2a\u6027\u5316\u670d\u52a1\u548c\u521b\u65b0\u7684\u5de5\u4e1a\u78c1\u94c1\u89e3\u51b3\u65b9\u6848\uff0c\u4ee5\u6ee1\u8db3\u60a8\u5e94\u7528\u7684\u786e\u5207\u9700\u6c42\u3002<\/p>\n

Industrial Magnetics \u7684\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1\u63d0\u4f9b\u5f00\/\u5173\u529f\u80fd\uff0c\u53ef\u5728\u81ea\u52a8\u94a3\u91d1\u5904\u7406\u7cfb\u7edf\u4e2d\u8fdb\u884c\u63a7\u5236\u3002\u901a\u8fc7\u65bd\u52a0\u53d7\u63a7\u7684\u76f4\u6d41\u7535\u6d41\uff0c\u7535\u78c1\u94c1\u80fd\u591f\u6839\u636e\u547d\u4ee4\u4fdd\u6301\u548c\u91ca\u653e\u542b\u94c1\u6750\u6599\u3002\u8fd9\u4e9b\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1\u5177\u6709\u5e7f\u6cdb\u7684\u5e94\u7528\u6f5c\u529b\uff0c\u56e0\u4e3a\u5b83\u4eec\u80fd\u591f\u901a\u8fc7\u6c14\u9699\uff08\u5373\u6d82\u6f06\u3001\u7535\u9540\u548c\u6d82\u5c42\u8868\u9762\uff09\u63d0\u4f9b\u66f4\u597d\u7684\u63a5\u89e6\u3002\u901a\u8fc7\u6269\u5c55\u63a5\u89e6\u8303\u56f4\uff0c\u8fd9\u4e9b\u78c1\u4f53\u53ef\u4ee5\u5728\u96f6\u4ef6\u8868\u9762\u4e0d\u5e73\u6574\u6216\u5f62\u72b6\u5947\u602a\u7684\u5730\u65b9\u5de5\u4f5c\uff0c\u65b9\u6cd5\u662f\u4e3a\u8fd9\u4e9b\u5e94\u7528\u4f7f\u7528\u5b9a\u5236\u52a0\u5de5\u7684\u6781\u9774\u3002<\/p>\n

\u529f\u80fd\u548c\u4f18\u70b9<\/p>\n

\u6240\u6709EP\u7cfb\u5217\u7535\u78c1\u4f53\u5c3a\u5bf8\u90fd\u670924\u4f0f\u76f4\u6d41\u548c\u4e00\u4e9b120\u4f0f\u4ea4\u6d41\u7535\u5c3a\u5bf8<\/p>\n

\u7d27\u51d1\u5c01\u88c5\u4e2d\u5177\u6709\u51fa\u8272\u7684\u78c1\u6027\u4fdd\u6301\u80fd\u529b<\/p>\n

1\u201c\u548c2\u201d\u5bbd\u578b\u53f7\u7684\u5e38\u89c1\u5b89\u88c5\u87ba\u6813\u5c3a\u5bf8<\/p>\n

\u8fde\u7eed\u5de5\u4f5c70\u00b0-95\u00b0C\u6e29\u5347<\/p>\n

\u4fa7\u9762\u5b89\u88c5\u7684\u63a5\u7ebf\u677f\u5141\u8bb8\u4e00\u6839\u5f15\u7ebf\u4ece\u78c1\u94c1\u8fde\u63a5\u5230\u7535\u6e90\uff08\u4e0d\u9700\u8981\u62fc\u63a5\uff0c\u6700\u5c0f18\u53f7\u5f15\u7ebf\uff09<\/p>\n\n\n\n\n\n\n\n\n\n\n\n
\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0Industrial Magnetics PARALLEL POLE Electromagnets\u7535\u78c1\u94c1<\/td>\n<\/tr>\n<\/thead>\n
Model No. – 24 VDC<\/th>\nLift (lbs)<\/th>\nLift (kg)<\/th>\nWidth (in)<\/th>\nLength (in)<\/th>\nHeight (in)<\/th>\nTap Size<\/th>\nHole Quantity<\/th>\nHole Spacing (in)<\/th>\nWatts<\/th>\nWeight (lbs)<\/th>\n<\/tr>\n
EP2-121<\/td>\n40<\/td>\n18.15<\/td>\n1<\/td>\n2<\/td>\n1-3\/8<\/td>\n1\/4-20<\/td>\n2<\/td>\n1<\/td>\n5<\/td>\n0.65<\/td>\n<\/tr>\n
EP2-131<\/td>\n85<\/td>\n38.56<\/td>\n1<\/td>\n3<\/td>\n1-3\/8<\/td>\n1\/4-20<\/td>\n2<\/td>\n2<\/td>\n7.3<\/td>\n1.00<\/td>\n<\/tr>\n
EP2-141<\/td>\n100<\/td>\n47.63<\/td>\n1<\/td>\n4<\/td>\n1-3\/8<\/td>\n1\/4-20<\/td>\n2<\/td>\n3<\/td>\n9.3<\/td>\n2.00<\/td>\n<\/tr>\n
EP2-242<\/td>\n230<\/td>\n106.60<\/td>\n2<\/td>\n4<\/td>\n2-3\/4<\/td>\n5\/16-18<\/td>\n2<\/td>\n3<\/td>\n21<\/td>\n5.00<\/td>\n<\/tr>\n
EP2-262<\/td>\n320<\/td>\n140.62<\/td>\n2<\/td>\n6<\/td>\n2-3\/4<\/td>\n5\/16-18<\/td>\n2<\/td>\n4.5<\/td>\n30<\/td>\n8.00<\/td>\n<\/tr>\n
EP2-282<\/td>\n430<\/td>\n210.93<\/td>\n2<\/td>\n8<\/td>\n2-3\/4<\/td>\n5\/16-18<\/td>\n2<\/td>\n6.5<\/td>\n36<\/td>\n10.00<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n
ER2-202<\/a>\nER2-403<\/a>\nERA-201<\/a>\nIndustrial Magnetics<\/a>\nIndustrial Magnetics DSC423-120<\/a>\nIndustrial Magnetics DSC424-120<\/a>\nIndustrial Magnetics EP2-121<\/a>\nIndustrial Magnetics ER2-071<\/a>\nIndustrial Magnetics MD001<\/a>\nIndustrial Magnetics\u4ee3\u7406<\/a>\nIndustrial Magnetics\u6c38\u78c1\u4f53<\/a>\nIndustrial Magnetics\u6c38\u78c1\u94c1<\/a>\nIndustrial Magnetics\u6d88\u78c1\u5668<\/a>\nIndustrial Magnetics\u7535\u78c1\u94c1<\/a>\nIndustrial Magnetics\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1<\/a>\nIndustrial Magnetics\u78c1\u529b\u5206\u5f20\u5668<\/a>\nIndustrial Magnetics\u78c1\u5316\u5668<\/a>\n\u5de5\u4e1a\u78c1\u4f53\u4ea7\u54c1<\/a>\n\u60ac\u6d6e\u7535\u78c1\u5206\u79bb\u5668<\/a>\n\u6d88\u78c1\u5668<\/a><\/div>","protected":false},"excerpt":{"rendered":"

\u7f8e\u56fdIndustrial Magnetics\u77e9\u5f62\u5e73\u884c\u6781\u7535\u78c1\u94c1,Industrial Magnetics EP2-121,EP2-131,EP2-141,EP2-242,Indust <\/p>\n","protected":false},"author":29,"featured_media":155,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[17,18,19,6,11,12,22,16,14,5,8,20,7,15,21,9,13,4,10,3],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/posts\/154"}],"collection":[{"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/users\/29"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/comments?post=154"}],"version-history":[{"count":2,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/posts\/154\/revisions"}],"predecessor-version":[{"id":157,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/posts\/154\/revisions\/157"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/media\/155"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/media?parent=154"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/categories?post=154"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/industrial-magnetics\/wp-json\/wp\/v2\/tags?post=154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}