{"id":139,"date":"2024-01-03T17:28:52","date_gmt":"2024-01-03T09:28:52","guid":{"rendered":"https:\/\/www.bihec.com\/leutron\/?p=139"},"modified":"2024-01-03T17:28:52","modified_gmt":"2024-01-03T09:28:52","slug":"%e5%be%b7%e5%9b%bdleutron-ct-t1-31-350-fm%e6%b5%aa%e6%b6%8c%e4%bf%9d%e6%8a%a4%e5%99%a8%e9%98%b2%e9%9b%b7%e5%99%a8%e9%81%bf%e9%9b%b7%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/leutron\/%e5%be%b7%e5%9b%bdleutron-ct-t1-31-350-fm%e6%b5%aa%e6%b6%8c%e4%bf%9d%e6%8a%a4%e5%99%a8%e9%98%b2%e9%9b%b7%e5%99%a8%e9%81%bf%e9%9b%b7%e5%99%a8\/","title":{"rendered":"\u5fb7\u56fdLEUTRON CT-T1\/3+1-350-FM\u6d6a\u6d8c\u4fdd\u62a4\u5668,LEUTRON\u9632\u96f7\u5668,LEUTRON\u907f\u96f7\u5668,LEUTRON\u539f\u88c5\u8fdb\u53e3"},"content":{"rendered":"
LEUTRON<\/a> CT-T1\/3+1-350-FM\u7528\u4e8e\u4e09\u76f8TT\u548cTN-S\u7cfb\u7edf\u7684\u5177\u6709\u7a00\u6709\u6c14\u4f53\u586b\u5145\u706b\u82b1\u9699\u7684\u96f7\u7535\u7535\u6d41\u653e\u7535\u907f\u96f7\u5668\uff08I\u7c7b\uff09\u3002\u5b83\u4eec\u63d0\u4f9b\u6781\u9ad8\u7684\u653e\u7535\u5bb9\u91cf\uff0c\u540c\u65f6\u5177\u6709\u6781\u4f4e\u7684\u4fdd\u62a4\u6c34\u5e73\uff0c\u5e76\u4e14\u5b83\u4eec\u4e5f\u4e0d\u9700\u8981\u4efb\u4f55\u53ef\u635f\u574f\u7684\u5185\u90e8\u6216\u5916\u90e8\u7535\u5b50\u89e6\u53d1\u5668\u3002<\/p>\n \u5fb7\u56fdLEUTRON CT-T1\/3+1-350-FM\u6d6a\u6d8c\u4fdd\u62a4\u5668,\u9632\u96f7\u5668,\u907f\u96f7\u5668,LEUTRON\u539f\u88c5\u8fdb\u53e3 LEUTRON CT-T1\/3+1-350-FM\u7528\u4e8e\u4e09\u76f8TT\u548cTN-S\u7cfb\u7edf\u7684 <\/p>\n","protected":false},"author":29,"featured_media":141,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[1],"tags":[10,7,6,9,8,11,3,5,4],"yoast_head":"\n\n
\n\n<\/thead>\n\n
\n Max. acceptable backup fuse (branch wiring)<\/td>\n 250 A gG<\/td>\n<\/tr>\n \n Max. acceptable backup fuse (V-type through wiring)<\/td>\n 125 A gG<\/td>\n<\/tr>\n \n Operating temperature rangeTU<\/span><\/td>\n -40 – +80 \u00b0C<\/td>\n<\/tr>\n \n Min. conductor cross section at terminals<\/td>\n 10 mm\u00b2 solid\/flexible<\/td>\n<\/tr>\n \n Max. conductor cross section<\/td>\n 50 mm\u00b2 stranded\/35 mm\u00b2 flexible<\/td>\n<\/tr>\n \n Recommended conductor cross section<\/td>\n 25 mm\u00b2<\/td>\n<\/tr>\n \n Max. connection torque for terminals<\/td>\n 4,0 Nm<\/td>\n<\/tr>\n \n Degree of protection (IEC EN 60529)<\/td>\n IP 20<\/td>\n<\/tr>\n \n Power supply system<\/td>\n 3 phase TNS and TT systems<\/td>\n<\/tr>\n \n Composed of: number of moduls<\/td>\n 3x 96 02 37 + 1x 96 02 38<\/td>\n<\/tr>\n \n Installation width<\/td>\n 147,2 mm<\/td>\n<\/tr>\n \n Max. conductor cross section FM<\/td>\n 1,5 mm\u00b2<\/td>\n<\/tr>\n \n Max. operating voltage remote contact FM<\/td>\n 250 V AC\/125 V DC<\/td>\n<\/tr>\n \n Max. operating current remote contact FM<\/td>\n 1 A AC\/200 mA DC<\/td>\n<\/tr>\n \n Max. locking torque FM terminals<\/td>\n 0,25 Nm<\/td>\n<\/tr>\n \n Inflammability class according to UL 94<\/td>\n V0<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ul>\n