{"id":381979,"date":"2022-12-11T21:06:46","date_gmt":"2022-12-11T13:06:46","guid":{"rendered":"https:\/\/www.bihec.com\/lk-technologies\/?p=381979"},"modified":"2022-12-11T21:06:46","modified_gmt":"2022-12-11T13:06:46","slug":"minicma%e7%94%b5%e5%ad%90%e8%83%bd%e8%b0%b1%e4%bb%aa-lk-technology-3","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/lk-technologies\/minicma%e7%94%b5%e5%ad%90%e8%83%bd%e8%b0%b1%e4%bb%aa-lk-technology-3\/","title":{"rendered":"MINICMA™\u7535\u5b50\u80fd\u8c31\u4eea LK Technology"},"content":{"rendered":"

MINICMA<\/a>™\u7535\u5b50\u80fd\u8c31\u4eea<\/a> LK Technology<\/a><\/p>\n

\"\"<\/p>\n

Analyzer \/ electron spectrum MINICMA™ \u5206\u6790\u5668\/\u7535\u5b50\u8c31minicma™<\/p>\n

Characteristics
\n\u7279\u70b9
\nMeasured value:
\n\u6d4b\u91cf\u503c\uff1a
\nelectron spectrum
\n\u7535\u5b50\u8c31
\nDescription
\n\u63cf\u8ff0
\nPerformance Features
\n\u6027\u80fd\u7279\u70b9
\nMounting on 2.75″ (70 mm) flange
\n\u5b89\u88c5\u57282.75\u201c\uff0870\u6beb\u7c73\uff09\u7684\u6cd5\u5170
\nRetractable with linear motion feedthrough
\n\u53ef\u4f38\u7f29\u7684\u7ebf\u6027\u8fd0\u52a8\u7684\u9988\u901a
\nGeneral electron energy analysis including
Auger<\/a> and Photoelectron spectroscopy
\n\u5305\u62ec\u4fc4\u6b47\u548c\u5149
\u7535\u5b50\u80fd\u8c31<\/a>\u7684\u4e00\u822c\u7535\u5b50\u80fd\u91cf\u5206\u6790
\nDouble-pass optics with energy resolution better than 1.5
\n\u53cc\u901a\u5149\u5b66\u4e0e\u80fd\u91cf\u5206\u8fa8\u7387\u4f18\u4e8e1.5
\nIdeal for experiments not accessible by conventional bulky analyzers
\n\u7406\u60f3\u7684\u5b9e\u9a8c\u4e0d\u53ef\u8bbf\u95ee\u7684\u5e38\u89c4\u7b28\u91cd\u7684\u5206\u6790\u4eea
\nCombine with the RVL2000
LEED<\/a> optics for a low-cost, high-performance LEED\/Auger system
\n\u7ed3\u5408\u4f4e\u6210\u672c\u7684\u9ad8\u6027\u80fd\u5149\u5b66rvl2000 LEED\uff0cLEED \/\u94bb\u7cfb\u7edf<\/p>\n

Analyzer \/ electron spectrum MINICMA™ \u5206\u6790\u5668\/\u7535\u5b50\u8c31minicma™<\/strong><\/p>\n

LK Technology<\/a>\nMINICMA<\/a>\n\u7535\u5b50\u80fd\u8c31\u4eea<\/a><\/div>","protected":false},"excerpt":{"rendered":"

MINICMA™\u7535\u5b50\u80fd\u8c31\u4eea LK Technology Analyzer \/ electron spectrum MINICMA™ \u5206\u6790\u5668\/\u7535\u5b50\u8c31min <\/p>\n","protected":false},"author":19,"featured_media":381927,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[3],"tags":[77,66,67],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/posts\/381979"}],"collection":[{"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/comments?post=381979"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/posts\/381979\/revisions"}],"predecessor-version":[{"id":381982,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/posts\/381979\/revisions\/381982"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/media\/381927"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/media?parent=381979"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/categories?post=381979"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/lk-technologies\/wp-json\/wp\/v2\/tags?post=381979"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}