{"id":180,"date":"2024-04-11T15:26:29","date_gmt":"2024-04-11T07:26:29","guid":{"rendered":"https:\/\/www.bihec.com\/monarchinstrument\/?p=180"},"modified":"2024-04-11T15:26:29","modified_gmt":"2024-04-11T07:26:29","slug":"%e7%be%8e%e5%9b%bd-monarch-instrument-act-1b-%e9%9d%a2%e6%9d%bf%e8%bd%ac%e9%80%9f%e8%a1%a8","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/monarchinstrument\/%e7%be%8e%e5%9b%bd-monarch-instrument-act-1b-%e9%9d%a2%e6%9d%bf%e8%bd%ac%e9%80%9f%e8%a1%a8\/","title":{"rendered":"\u7f8e\u56fd Monarch Instrument ACT-1B \u9762\u677f\u8f6c\u901f\u8868"},"content":{"rendered":"
ACT-1B \u9762\u677f\u8f6c\u901f\u8868\u4e0e\u6240\u6709\u5e26\u6709\u9540\u9521\u7ebf\u201c-W\u201d\u8fde\u63a5\u7684 Monarch \u901f\u5ea6\u4f20\u611f\u5668\u517c\u5bb9\u3002\u5b83\u53ef\u6309\u60a8\u7684\u89c4\u683c\u8fdb\u884c\u51fa\u5382\u914d\u7f6e\uff0c\u6216\u4f7f\u7528\u53ef\u9009\u7684 USB \u7f16\u7a0b\u7535\u7f06\u8fdb\u884c\u73b0\u573a\u7528\u6237\u914d\u7f6e\u3002USB \u7f16\u7a0b\u7535\u7f06\u548c\u53ef\u514d\u8d39\u4e0b\u8f7d\u7684PM \u8fdc\u7a0b\u8f6f\u4ef6<\/strong>\u8fd8\u5141\u8bb8\u5728\u672c\u5730 PC \u4e0a\u5b9e\u65f6\u663e\u793a\u548c\u8bb0\u5f55\u6570\u636e\u3002\u00a0\u63d0\u4f9b\u53ef\u9009\u7684 NIST \u53ef\u8ffd\u6eaf\u8bc1\u4e66\u3002<\/p>\n <\/p>\n <\/p>\n <\/p>\n \u6240\u6709\u578b\u53f7 – \u901a\u7528\u8f93\u5165\uff0c\u901a\u8fc7\u5149\u5b66\u3001\u7ea2\u5916\u3001\u6fc0\u5149\u3001\u63a5\u8fd1\u548c\u78c1\u6027\u4f20\u611f\u5668\u6216\u76f4\u63a5 TTL \u548c 3.3 \u81f3 50 V \u4ea4\u6d41\u4fe1\u53f7\u8fdb\u884c\u975e\u63a5\u89e6\u5f0f\u64cd\u4f5c<\/p>\n ACT-1B \u9762\u677f\u8f6c\u901f\u8868<\/strong><\/p>\n Proximity –\u00a0P5-11<\/p>\n Magnetic –\u00a0\u00a0M-190W\u00a0or\u00a0MT-190W<\/p>\n Infrared –\u00a0IRS-W<\/p>\n Laser –\u00a0ROLS-W\u00a0or\u00a0RLS-W<\/td>\n<\/tr>\n (Positive or negative out programmable\u2020)<\/td>\n<\/tr>\n Operating Temperature:<\/strong> 32 \u00b0F – 122 \u00b0F [0 \u00b0C – 50 \u00b0C] \u7f8e\u56fd Monarch Instrument ACT-1B \u9762\u677f\u8f6c\u901f\u8868 \u63cf\u8ff0 ACT-1B \u9762\u677f\u8f6c\u901f\u8868\u4e0e\u6240\u6709\u5e26\u6709\u9540\u9521\u7ebf\u201c-W\u201d\u8fde\u63a5\u7684 Monarch \u901f\u5ea6\u4f20\u611f\u5668\u517c\u5bb9\u3002\u5b83\u53ef\u6309\u60a8\u7684\u89c4\u683c\u8fdb <\/p>\n","protected":false},"author":16,"featured_media":181,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[19],"tags":[20,7,11,6,9,13,16,5,18],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/posts\/180"}],"collection":[{"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/comments?post=180"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/posts\/180\/revisions"}],"predecessor-version":[{"id":184,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/posts\/180\/revisions\/184"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/media\/181"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/media?parent=180"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/categories?post=180"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/monarchinstrument\/wp-json\/wp\/v2\/tags?post=180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}\u7279\u5f81<\/h2>\n
\n
\u89c4\u683c*<\/h2>\n
\n\n
\n Speed Range<\/strong><\/td>\n 5 to 99,999 RPM<\/td>\n<\/tr>\n \n Accuracy<\/strong><\/td>\n \u00b11 RPM or 0.005% of reading<\/td>\n<\/tr>\n \n Resolution<\/strong><\/td>\n 1 RPM (user-programmable to 0.0001\u2020)<\/td>\n<\/tr>\n \n Display<\/strong><\/td>\n 5-digit, 0.56 in. [14 mm] high red LED<\/td>\n<\/tr>\n \n Display Update<\/strong><\/td>\n Twice per second above 120 RPM\u00a0\u00a0(user-programmable to 0.5, 1 or 1.5 second\u2020)<\/td>\n<\/tr>\n \n Dimensions<\/strong><\/td>\n 1\/8 DIN by 4.5 in. [114 mm] deep\u00a0Panel cutout: 3.58″ x 1.74″ [91 x 44 mm]<\/td>\n<\/tr>\n \n Power Supply<\/strong><\/td>\n Standard: 100-240 V ac \u00b110%, 50\/60 Hz,
\nOptional: 12 or 24 V dc \u00b110%, Isolated, 5.0 Watts<\/td>\n<\/tr>\n\n Inputs<\/strong><\/td>\n Universal input for optical, proximity, two-wire, or three-wire magnetic, infrared, or laser sensors
\nTTL input or 2 V ac to 50 V ac peak to peak input
\nStandard input is 1 pulse per revolution (user-programmable from 1 to 999\u2020)<\/td>\n<\/tr>\n\n Sensor Excitation<\/strong><\/td>\n 12 V dc at 20 mA for proximity sensors,
\n12 V dc at 75 mA for all other sensors;
\nOptional 5 or 24 V dc available<\/td>\n<\/tr>\n\n Recommended Sensors<\/strong><\/td>\n Optical –\u00a0ROS-W,\u00a0ROS-HT-W-25<\/p>\n \n IO Option<\/strong><\/td>\n 4 to 20 mA out, 16-bit resolution 12 V dc compliance voltage Full-scale RPM settings as specified when ordered
\n(user-programmable\u2020)<\/td>\n<\/tr>\n\n Analog Output\u00a0(option)<\/strong><\/td>\n 0 to 5 V dc, 5 mA\u00a016-bit resolution
\nFull-scale RPM settings as specified when ordered
\n(user-programmable\u2020)<\/td>\n<\/tr>\n\n PO (option)<\/strong><\/td>\n 0 to 5 V TTL pulse, non-inverting, one pulse out for each pulse in<\/p>\n \n Environmental<\/strong><\/td>\n This product is designed to be safe for indoor use under the following conditions (per IEC61010-1):
\nInstallation Category II<\/strong>\u00a0per IEC 664
\nPollution Degree Level II<\/strong>\u00a0per IEC 664<\/p>\n
\nHumidity:<\/strong>\u00a0Maximum relative humidity 80% for temperature up to 88 \u00b0F (31 \u00b0C) decreasing linearly to 50% relative humidity at 104 \u00b0F (40 \u00b0C)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n