{"id":66,"date":"2017-12-29T18:06:03","date_gmt":"2017-12-29T10:06:03","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/pslrheotek\/?p=66"},"modified":"2019-06-21T13:57:17","modified_gmt":"2019-06-21T05:57:17","slug":"integrated-polymer-sample-preparation","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/psl-rheotek\/integrated-polymer-sample-preparation\/","title":{"rendered":"\u96c6\u6210\u805a\u5408\u7269\u6837\u54c1\u5236\u5907\u7cfb\u7edf"},"content":{"rendered":"

Polymer sample preparation PSL-Rheotek
\n<\/span><\/p>\n

\"\"<\/p>\n

ISP-1 Sample Preparation, supplied complete with precision balance, syringe Pump and voice promting software.<\/p>\n

FAST \u2013 samples can be prepared in under 75 seconds.<\/p>\n

Sample details are automatically transferred to the RPV-1<\/a>.<\/p>\n

Uses weight to weight data rather than weight to volume data to calculate concentration \u2013 avoids errors due to temperature\/density.<\/p>\n

Built-in safety checks.<\/p>\n

Automatic ASH & MOISTURE corrections to concentration.<\/p>\n

Uses AUDIO prompts to talk the operator through the essential preparation steps.<\/p>\n

Pre-programmed methods make preparation simple and straightforward.<\/p>\n

– Simple & Safe to use<\/p>\n

– Improves accuracy<\/p>\n

– Saves operator time<\/p>\n

– Reduces exposure to hazardous chemicals<\/p>\n

– Standard model suitable for most polymer applications<\/p>\n

– Balance: 4 decimal place<\/p>\n

– Interface: RS232C<\/p>\n

– iSP-1 synge pump, 25ml<\/p>\n

– Interface: RS232C<\/p>\n

FULLY AUTOMATED SAMPLE PREPA<\/a>RATION SYSTEM to make accurate polymer concentrations<\/p>\n

– W\/W%<\/p>\n

– W\/V%<\/p>\n

– Density<\/p>\n

– Ash %<\/p>\n

– Moisture %<\/p>\n

Complete with\u2026<\/p>\n

BALANCE & PUMP<\/p>\n

[uses PC<\/a> on RPV-1]<\/p>\n

Test Methods<\/p>\n

ASTM D789<\/a>, ISO 307<\/a>, ASTM D4603<\/a>, ASTM 2857, ASTM D1795<\/a>, SCAN CM15:99, TAPP<\/a>I T230-OM94, ASTM D1243<\/a>, USP<911> Viscosity, ISO1628<\/p>\n

The software is updated regularly \u2013 taking into account new methods or customer specific requests. Therefore if your method is not mentioned in the above list then please contact us.<\/p>\n

Advantages<\/p>\n

Simple & Safe to use<\/p>\n

Improves accuracy<\/p>\n

Saves operator time<\/p>\n

Reduces exposure to hazardous chemicals<\/p>\n

Ensures compliance with test methods<\/p>\n

Description<\/p>\n

Simple Operation<\/p>\n

Operator selects one of the pre-programmed methods, types in the sample ID & presses the “Prepare Solution” button. The iSP-1 then takes over and asks the operator for the vial. The iSP-1 uses a series of audio prompts to instruct the operator how to prepare the sample. Safety checks ensure that the vial is placed on the balance. ISP-1 then asks for the sample. The operator adds sample until the iSP-1 prompts them to stop adding sample. Finally the iSP-1 calculates the correct amount of solvent and dispenses it into the vial.<\/p>\n

Safety<\/p>\n

Various safety checks throughout the process ensure the operators safety and prevent solvent being dispensed incorrectly.<\/p>\n

Automatic Calculations, Results Database & LIMS<\/p>\n

Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.<\/p>\n

Materials of construction & design<\/p>\n

The iSP-1 is supplied with a high quality MT balance. The iSP-1 pump is supplied with a tough chemical resistant coating. The pump can be disassembled for easy maintenance.<\/p>\n

Sample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.<\/p>\n

Typical Applications<\/p>\n

– Pulp, Paper & Microcrystalline Cellulose, according to ASTM D1795 and SCAN CM15:98, TAPPI T230-OM94<\/p>\n

– Nylon according to ASTM D789 [HIGH CONCENTRATION]<\/p>\n

– Nylon according to ISO307[LOW CONCENTRATION]<\/p>\n

PET<\/a> according to ASTM D4603<\/p>\n

PE<\/a>T in OCP [Orthochlorophenol]<\/p>\n

– PET in Phenol\/Dichlorobenzene<\/p>\n

\u7279\u6027\u7c98\u5ea6\u8ba1<\/a>\uff0c\u8bf7\u8054\u7cfb<\/span><\/span>15821107090<\/span>\uff0c \u4e13\u4e1a\u5de5\u7a0b\u5e08\u4e3a\u60a8\u63d0\u4f9b\u89e3\u51b3\u65b9\u6848<\/span><\/p>\n

ASTM Ubbelohde<\/a>\nAutoPulpIVA<\/a>\nmicro-Ubbelohde<\/a>\nPA<\/a>\nPBT<\/a>\nPC<\/a>\nPE<\/a>\nPET<\/a>\nPLA<\/a>\nPP<\/a>\nPSL-rheotek<\/a>\nPVC<\/a>\nRPV-1\u4e24\u901a\u9053\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\nRPV-1\u56db\u901a\u9053\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\nRPVm<\/a>\n\u5168\u81ea\u52a8\u7c98\u5ea6\u8ba1<\/a>\n\u6cb9\u58a8<\/a>\n\u73bb\u7483\u6bdb\u7ec6\u7ba1<\/a>\n\u751f\u7269\u805a\u5408\u7269<\/a>\n\u7ea2\u5916\u5149\u5b66\u6d4b\u91cf\u5934<\/a>\n\u7eb8\u6d46\u6837\u54c1\u5168\u81ea\u52a8\u7c98\u5ea6\u8ba1<\/a>\n\u7eb8\u6d46\u7c98\u5ea6\u8ba1<\/a>\n\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\n\u918b\u9178\u7ea4\u7ef4\u7d20<\/a><\/div>","protected":false},"excerpt":{"rendered":"

Polymer sample preparation PSL-Rheotek ISP-1 Sample Preparation, supplied complete with pr <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[11,4],"tags":[37,42,38,15,19,20,21,16,18,22,28,17,40,41,39,30,24,36,25,35,43,13,12,23],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts\/66"}],"collection":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/comments?post=66"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts\/66\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/media?parent=66"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/categories?post=66"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/tags?post=66"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}