{"id":72,"date":"2017-12-29T18:10:20","date_gmt":"2017-12-29T10:10:20","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/pslrheotek\/?p=72"},"modified":"2019-06-21T13:57:30","modified_gmt":"2019-06-21T05:57:30","slug":"pp-pe-high-density-integrated-sample-preparation-system","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/psl-rheotek\/pp-pe-high-density-integrated-sample-preparation-system\/","title":{"rendered":"PP\/PE\u9ad8\u5bc6\u5ea6\u7efc\u5408\u6837\u54c1\u5236\u5907\u7cfb\u7edf"},"content":{"rendered":"

PP<\/a>\/PE<\/a> High Density iSP PSL-Rheotek
\n<\/span><\/p>\n

\"\"<\/p>\n

Sample details are automatically transferred to the RPV-1<\/a>.<\/p>\n

Uses weight to weight data rather than weight to volume data to calculate concentration \u2013 avoids errors due to temperature\/density.<\/p>\n

Built in safety checks.<\/p>\n

Automatic ASH & MOISTURE corrections to concentration.<\/p>\n

Uses AUDIO prompts to talk the operator through the essential preparation steps.<\/p>\n

Pre-programmed methods make preparation simple and straightforward.<\/p>\n

– Simple & Safe to use<\/p>\n

– Improves accuracy<\/p>\n

– Saves operator time<\/p>\n

– Reduces exposure to hazardous chemicals<\/p>\n

– Standard model suitable for most polymer applications<\/p>\n

– Pulp model complete with two syringe pumps<\/p>\n

– HD model for high density PP samples<\/p>\n

– Balance: 5 decimal place<\/p>\n

– Interface: RS232C<\/p>\n

– iSP-1 synge pump, 25ml<\/p>\n

– Interface: RS232C<\/p>\n

*Other balances are available.<\/p>\n

FULLY AUTOMATED SAMPLE PREPA<\/a>RATION SYSTEM to make accurate polymer concentrations
\n<\/span><\/p>\n

– W\/W%
\n– W\/V%
\n– Density
\n– Ash %
\n– Moisture %
\n<\/span><\/p>\n

Complete with\u2026
\nBALANCE & PUMP
\n[uses
PC<\/a> on RPV-1]
\n<\/span><\/p>\n

Test Methods
\n<\/strong>
ISO 1628<\/a>
\n<\/span><\/p>\n

The software is updated regularly \u2013 taking into account new methods or customer specific requests. Therefore if your method is not mentioned in the above list then please contact us.
\n<\/span><\/p>\n

Advantages
\n<\/strong>Simple & Safe to use
\nImproves accuracy
\nSaves operator time
\nReduces exposure to hazardous chemicals
\nEnsures compliance with test methods
\n<\/span><\/p>\n

Description
\n<\/strong>Simple Operation
\nOperator selects one of the pre-programmed methods, types in the sample ID & presses the “Prepare Solution” button. The iSP-1 then takes over and asks the operator for the vial. The iSP-1 uses a series of audio prompts to instruct the operator how to prepare the sample. Safety checks ensure that the vial is placed on the balance. ISP-1 then asks for the sample. The operator adds sample until the iSP-1 prompts them to stop adding sample. Finally the iSP-1 calculates the correct amount of solvent and dispenses it into the vial.
\n<\/span><\/p>\n

Safety<\/strong>
\nVarious safety checks throughout the process ensure the operators safety and prevent solvent being dispensed incorrectly.<\/span><\/p>\n

Automatic Calculations, Results Database & LIMS<\/strong>
\nSample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.<\/p>\n

Materials of construction & design<\/strong>
\nThe iSP-1 is supplied with a high quality MT balance. The iSP-1 pump is supplied with a\u00a0tough\u00a0chemical resistant coating. The pump can be disassembled for easy maintenance.
\nSample information is stored and can be sent automatically to the RPV-1 Polymer Viscometer if required.
\n<\/span><\/p>\n

Typical Applications<\/strong><\/span><\/p>\n

PP\/PE measured at High Temperature<\/p>\n

\u7279\u6027\u7c98\u5ea6\u8ba1<\/a>\uff0c\u8bf7\u8054\u7cfb<\/span><\/span>15821107090<\/span>\uff0c \u4e13\u4e1a\u5de5\u7a0b\u5e08\u4e3a\u60a8\u63d0\u4f9b\u89e3\u51b3\u65b9\u6848<\/span><\/p>\n

ASTM Ubbelohde<\/a>\nAutoPulpIVA<\/a>\nmicro-Ubbelohde<\/a>\nPA<\/a>\nPBT<\/a>\nPC<\/a>\nPE<\/a>\nPET<\/a>\nPLA<\/a>\nPP<\/a>\nPSL-rheotek<\/a>\nPVC<\/a>\nRPV-1\u4e24\u901a\u9053\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\nRPV-1\u56db\u901a\u9053\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\nRPVm<\/a>\n\u5168\u81ea\u52a8\u7c98\u5ea6\u8ba1<\/a>\n\u6cb9\u58a8<\/a>\n\u73bb\u7483\u6bdb\u7ec6\u7ba1<\/a>\n\u751f\u7269\u805a\u5408\u7269<\/a>\n\u7ea2\u5916\u5149\u5b66\u6d4b\u91cf\u5934<\/a>\n\u7eb8\u6d46\u6837\u54c1\u5168\u81ea\u52a8\u7c98\u5ea6\u8ba1<\/a>\n\u7eb8\u6d46\u7c98\u5ea6\u8ba1<\/a>\n\u805a\u5408\u7269\u7c98\u5ea6\u8ba1<\/a>\n\u918b\u9178\u7ea4\u7ef4\u7d20<\/a><\/div>","protected":false},"excerpt":{"rendered":"

PP\/PE High Density iSP PSL-Rheotek Sample details are automatically transferred to the RPV <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[11,4],"tags":[37,42,38,15,19,20,21,16,18,22,28,17,40,41,39,30,24,36,25,35,43,13,12,23],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts\/72"}],"collection":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/comments?post=72"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/posts\/72\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/media?parent=72"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/categories?post=72"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/psl-rheotek\/wp-json\/wp\/v2\/tags?post=72"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}