{"id":197,"date":"2023-06-26T11:07:23","date_gmt":"2023-06-26T03:07:23","guid":{"rendered":"https:\/\/www.bihec.com\/realtechwater\/?p=197"},"modified":"2023-06-26T11:07:23","modified_gmt":"2023-06-26T03:07:23","slug":"%e5%8a%a0%e6%8b%bf%e5%a4%a7real-tech-high-nitrite-sensor-%e9%ab%98%e4%ba%9a%e7%a1%9d%e9%85%b8%e7%9b%90%e4%bc%a0%e6%84%9f%e5%99%a8","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/realtechwater\/%e5%8a%a0%e6%8b%bf%e5%a4%a7real-tech-high-nitrite-sensor-%e9%ab%98%e4%ba%9a%e7%a1%9d%e9%85%b8%e7%9b%90%e4%bc%a0%e6%84%9f%e5%99%a8\/","title":{"rendered":"\u52a0\u62ff\u5927Real Tech HIGH NITRITE SENSOR \u9ad8\u4e9a\u785d\u9178\u76d0\u4f20\u611f\u5668"},"content":{"rendered":"
\u52a0\u62ff\u5927Real Tech HIGH NITRITE SENSOR \u9ad8\u4e9a\u785d\u9178\u76d0\u4f20\u611f\u5668<\/a><\/p>\n Parameter(s): Nitrite (NO2<\/sub>) \u4e9a\u785d\u9178\u76d0<\/a><\/p>\n <\/p>\n \u52a0\u62ff\u5927Real Tech HIGH NITRITE SENSOR \u9ad8\u4e9a\u785d\u9178\u76d0\u4f20\u611f\u5668 Parameter(s): Nitrite (NO2) \u4e9a\u785d\u9178\u76d0 \u9ad8\u4e9a\u785d\u9178\u76d0\u4f20\u611f\u5668 <\/p>\n","protected":false},"author":19,"featured_media":198,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[1],"tags":[24,30,28,34,32,7,5,36,25,10,9,47,20,48,45],"yoast_head":"\n<\/p>\n
\n\n
\n CHARACTERISTIC<\/td>\n TECHNICAL DATA<\/td>\n<\/tr>\n \n Path Lengths<\/td>\n 0.5, 1, 2, 4, 10 mm (1000 series)
\n1, 2, 4, 8 mm (2000 series)
\n25, 50, 100, 150 mm (4000 series)<\/td>\n<\/tr>\n\n Parameters<\/td>\n Nitrite (NO2<\/sub>)<\/td>\n<\/tr>\n \n Range<\/td>\n Depends on model selected. Refer to range chart on next tab.<\/td>\n<\/tr>\n \n Accuracy<\/td>\n \u00b1 0.5% full scale<\/td>\n<\/tr>\n \n Units<\/td>\n mg\/L, ppm<\/td>\n<\/tr>\n \n Sampling Time<\/td>\n 30 seconds<\/td>\n<\/tr>\n \n Calibration<\/td>\n Factory calibrated. Field adjustment of calibration is possible.<\/td>\n<\/tr>\n \n Cleaning<\/td>\n In-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional.<\/td>\n<\/tr>\n \n Self-Diagnostic<\/td>\n Detection and diagnosis of internal system fault<\/td>\n<\/tr>\n \n Alarms<\/td>\n Dry contact terminals allow operator configurable alarms for:
\nhigh and low set points, low lamp output, leak detect, system fault, etc.<\/td>\n<\/tr>\n\n Humidity Control<\/td>\n Humidity sensor with large regeneratable desiccant system<\/td>\n<\/tr>\n \n Wavelengths<\/td>\n UV and visible light wavelengths<\/td>\n<\/tr>\n \n Light Source<\/td>\n UV LED<\/td>\n<\/tr>\n \n Flow Rate<\/td>\n 500 – 1000 mL\/min (1000 series)
\n300 – 1000 mL\/min (2000 and 4000 series)<\/td>\n<\/tr>\n\n Pressure Rating<\/td>\n 85 PSI maximum (1000 series)
\n20 PSI maximum (2000 and 4000 series)<\/td>\n<\/tr>\n\n Fluid Connections<\/td>\n 3\/8″ OD tube push-in fittings (1000 series)
\n1\/4″ OD tube push-in fittings (2000 and 4000 series)<\/td>\n<\/tr>\n\n Wetted Materials<\/td>\n Kynar, FEP, Quartz, SS316L, Viton (1000 series)
\nKynar, Polyethylene, Quartz, SS 316L, Viton (2000 and 4000 series)<\/td>\n<\/tr>\n\n Electrical\/Comm.<\/td>\n From controller<\/td>\n<\/tr>\n \n Ambient Temp.<\/td>\n 0 to 45\u00b0C (32 to 113\u00b0F)<\/td>\n<\/tr>\n \n Water Temp.<\/td>\n 0 to 90\u00b0C (32 to 194\u00b0F) at 21\u00b0C (69.8\u00b0F) Ambient temperature<\/td>\n<\/tr>\n \n Enclosure<\/td>\n NEMA 4X, wall mountable<\/td>\n<\/tr>\n \n Weight<\/td>\n 22 lb (1000 and 2000 series)
\n24 lb (4000 series)<\/td>\n<\/tr>\n\n Dimensions<\/td>\n 17″H x 14.25″W x 7.5″D (1000 and 2000 series)
\n15.82\u201dH x 13.82\u201dW x 9.00\u201dD (4000 series)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n