\n
OX-07 \u662f\u4e00\u6b3e\u7528\u4e8e\u4eba\u8eab\u5b89\u5168\u7684\u5c0f\u578b\u5355\u6c14\u4f53\u76d1\u6d4b\u4eea\u3002\u7531\u4e8e\u4f53\u79ef\u5c0f\u3001\u91cd\u91cf\u8f7b\u548c\u5927\u6db2\u6676\u663e\u793a\u5c4f\uff0c\u8be5\u4eea\u5668\u975e\u5e38\u6613\u4e8e\u64cd\u4f5c\uff0c\u4e0d\u4f1a\u5728\u5de5\u4f5c\u65f6\u59a8\u788d\u7528\u6237\u3002\u8be5\u8bbe\u5907\u914d\u5907\u4e86\u58f0\u97f3\u3001\u89c6\u89c9\u548c\u632f\u52a8\u8b66\u62a5\uff0c\u4ee5\u5f15\u8d77\u7528\u6237\u5bf9\u5371\u9669\u6c14\u4f53\u73af\u5883\u7684\u6ce8\u610f\u3002<\/p>\n
\u7279\u5f81\uff1a<\/strong><\/p>\n\n- \u5e26\u81ea\u52a8\u80cc\u5149\u7684\u5927\u578b LCD \u663e\u793a\u5c4f<\/li>\n
- \u89c6\u89c9\u3001\u542c\u89c9\u548c\u632f\u52a8\u8b66\u62a5<\/li>\n
- \u5c0f\u5de7\u8f7b\u4fbf<\/li>\n
- \u957f\u8fbe 5000 \u5c0f\u65f6\u8fde\u7eed\u8fd0\u884c<\/li>\n
- \u6297\u51b2\u51fb\u4fdd\u62a4\u6a61\u80f6\u9774<\/li>\n
- \u8fdc\u7a0b\u76d1\u63a7\u5ef6\u957f\u7ebf<\/li>\n
- \u672c\u8d28\u5b89\u5168\uff0cEEx ia IIC T3 \u548c MED \u8ba4\u8bc1<\/li>\n<\/ul>\n
\u63cf\u8ff0<\/div>\n
\n
\n
\n
OX-07 \u53ea\u9700\u4e00\u5bf9\u78b1\u6027\u7535\u6c60\u5373\u53ef\u8fd0\u884c\u957f\u8fbe 5000 \u5c0f\u65f6\uff08\u65e0\u8b66\u62a5\u548c\u80cc\u5149\uff09\u3002<\/p>\n
\u8be5\u8bbe\u5907\u5177\u6709\u7b26\u5408 Ex ia IIC T3 \u7684\u672c\u8d28\u5b89\u5168\u8bbe\u8ba1\uff0c\u4f7f\u5176\u9002\u7528\u4e8e\u5404\u79cd\u4e0d\u540c\u7684\u5e94\u7528\u3002\u5b83\u4e5f\u5f97\u5230\u4e86\u65e5\u672c\u52b3\u52a8\u7701\u7684\u6279\u51c6\u3002<\/p>\n
<\/p>\n
\u6280\u672f\u53c2\u6570<\/p>\n
\n
\n
\n\n\n\n\n\n\n\n\n \n \n \n\n\nModel<\/strong><\/td>\nTyp A<\/strong><\/td>\nTyp B<\/strong><\/td>\n<\/tr>\n\nGas detected<\/strong><\/td>\nOxygen in air<\/td>\n<\/tr>\n | \nDetection principle<\/strong><\/td>\nGalvanic Cell<\/td>\n<\/tr>\n | \nDetection range (increments)<\/strong><\/td>\n0-40% vol (0.1% vol)<\/td>\n<\/tr>\n | \nAlarm set points<\/strong><\/td>\nLow alarm\u00a0\u00a0 \u00a019.5% vol<\/p>\n High alarm\u00a0\u00a0 \u00a023.5% vol<\/p>\n Over\u00a0\u00a0 \u00a040.0% vol<\/td>\n | No alarm<\/td>\n<\/tr>\n | \nTrouble alarm<\/strong><\/td>\nSensor disconnection, low battery, circuit failure, calibration range error<\/td>\n<\/tr>\n | \nAlarm types<\/strong><\/td>\nGas alarm:\u00a0\u00a0 \u00a0flashing light, intermittent buzzer \nand flashing gas value, pulsing \nvibration<\/td>\n | No alarm<\/td>\n<\/tr>\n | \nTrouble alarm: flashing light, intermittent buzzer and display of error message<\/td>\n<\/tr>\n | \nDisplay<\/strong><\/td>\nDigital LCD display<\/td>\n<\/tr>\n | \nPower source<\/strong><\/td>\n2 \u201cAA\u201d alkaline batteries<\/td>\n<\/tr>\n | \nContinuous operation \n<\/strong><\/p>\n <\/td>\n Maximum 5000 hours (at 25\u00b0C, without alarm and backlight)<\/td>\n<\/tr>\n | \nSafety design<\/strong><\/td>\nIntrinsically safe (EEx ia IIC T3)<\/td>\n<\/tr>\n | \nOperating temp. & humidity<\/strong><\/td>\n-20\u00b0C to +50\u00b0C, max. 90% RH non-condensing<\/td>\n<\/tr>\n | \nSpecial functions<\/strong><\/td>\nManual backlight for LCD (automatically lit during alarm)<\/p>\n Peak hold (maximum and minimum)<\/td>\n<\/tr>\n | \nDimensions & weight<\/strong><\/td>\nApprox. 66(W) x 114(H) x 33(D)mm, approx. 230g (instrument only)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n <\/p>\n<\/div>\n<\/div>\n<\/div>\n
FP-31<\/a>\nGP-1000 Eingas-Monitor<\/a>\nOX-07<\/a>\n\u4fbf\u643a\u5f0f\u6c27\u6c14\u76d1\u6d4b\u4eea<\/a>\n\u4fbf\u643a\u5f0f\u7532\u919b\u76d1\u6d4b\u4eea<\/a>\n\u6c14\u4f53\u68c0\u6d4b\u7ba1<\/a><\/div>","protected":false},"excerpt":{"rendered":"OX-07 Portable Oxyen Monitor \u4fbf\u643a\u5f0f\u6c27\u6c14\u76d1\u6d4b\u4eea OX-07 \u662f\u4e00\u6b3e\u7528\u4e8e\u4eba\u8eab\u5b89\u5168\u7684\u5c0f\u578b\u5355\u6c14\u4f53\u76d1\u6d4b\u4eea\u3002\u7531\u4e8e\u4f53\u79ef\u5c0f\u3001\u91cd\u91cf\u8f7b\u548c\u5927\u6db2\u6676\u663e\u793a\u5c4f\uff0c\u8be5\u4eea\u5668 <\/p>\n","protected":false},"author":16,"featured_media":134,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[10],"tags":[5,9,12,11,4,7],"yoast_head":"\n \u5fb7\u56fd RKI Analytical Instruments OX-07 Portable Oxyen Monitor \u4fbf\u643a\u5f0f\u6c27\u6c14\u76d1\u6d4b\u4eea - RKI Analytical Instruments GmbH \u6c14\u4f53\u76d1\u6d4b\u4eea\uff0c\u4fbf\u643a\u5f0f\u6c14\u4f53\u76d1\u6d4b\u4eea\uff0c\u4fbf\u643a\u5f0f\u591a\u6c14\u4f53\u68c0\u6d4b\u4eea<\/title>\n\n\n\n\n\n\n\n\n\n\n\t\n\t\n\n\n\t\n\t\n\t\n | | | | | | | | | | | | | | | | | | |