{"id":222,"date":"2025-05-12T16:39:38","date_gmt":"2025-05-12T08:39:38","guid":{"rendered":"https:\/\/www.bihec.com\/rotexautomationvalve\/?p=222"},"modified":"2025-05-12T16:39:38","modified_gmt":"2025-05-12T08:39:38","slug":"rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/","title":{"rendered":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df"},"content":{"rendered":"

\"\"
\n20101
\n\u7aef\u53e3\u5927\u5c0f<\/a>\uff1a1\/8″
\n
\u6cd5\u5170\u7c7b<\/a>\uff1aNPT\/BSP
\n
\u6700\u5927\u538b\u529b<\/a>\uff1a2.5bar
\n
\u4f5c\u5458\u5927\u5c0f<\/a>\uff1a5
\n
\u6d41\u91cf\u7cfb\u6570<\/a>\uff1a8
\n\u884c\u4e1a\uff1a<\/strong>\u77f3\u6cb9\u548c\u5929\u7136\u6c14\uff0c
\u5316\u5de5<\/a>\uff0c \u706b\u529b\u53d1\u7535<\/a>\uff0c \u6c34\u6ce5<\/a>\uff0c \u91d1\u5c5e<\/a>\u548c\u77ff\u5c71<\/a>\uff0c \u98df\u54c1\u548c\u996e\u6599\uff0c \u6838\u7535<\/a>\uff0c \u9020\u7eb8<\/a>\u548c\u7eb8\u6d46\uff0c \u8f6e\u80ce\u5de5\u4e1a\uff0c \u7eba\u7ec7\uff0c \u77f3\u6cb9\u548c\u5929\u7136\u6c14
\n\u8bc1\u4e66\uff1a<\/strong>
ATEX<\/a> |CCOE\/PESO<\/a> \u4ea4\u6613 |CUTR-EAC |IEC \u9632\u7206<\/a> |INMETRO \u516c\u53f8 |\u4e4c\u514b\u5170 |CE<\/a> |UL<\/a><\/h3>\n

\"\"<\/p>\n

20108
\n
\u7aef\u53e3<\/a>\u5927\u5c0f\uff1a\u5e95\u57fa
\n\u6700\u5927
\u538b\u529b<\/a>\uff1a2.5\/4\/6\/8\/12\/15\/20\/60
\n\u4f5c\u5458\u5927\u5c0f\uff1a1.2\/1.8\/2.22.5\/3\/3.5\/4\/5
\n\u6d41\u91cf\u7cfb\u6570\uff1a0.7\/1.8\/2.5\/3.5\/4\/5\/7\/8
\n\u884c\u4e1a\uff1a<\/strong>\u706b\u529b\u53d1\u7535\u3001\u6c34\u6ce5\u3001\u91d1\u5c5e\u548c\u77ff\u5c71<\/h3>\n

 <\/p>\n

CE<\/a>\nIEC \u9632\u7206<\/a>\nPESO<\/a>\nROTEX<\/a>\nUL<\/a>\n\u538b\u529b<\/a>\n\u6838\u7535<\/a>\n\u6c34\u6ce5<\/a>\n\u6cd5\u5170<\/a>\n\u6d41\u91cf\u7cfb\u6570<\/a>\n\u706b\u529b\u53d1\u7535<\/a>\n\u77ff\u5c71<\/a>\n\u7aef\u53e3<\/a>\n\u9020\u7eb8<\/a>\n\u91d1\u5c5e<\/a><\/div>","protected":false},"excerpt":{"rendered":"

ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df<\/p>\n","protected":false},"author":37,"featured_media":225,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[4,5],"tags":[13,11,12,6,14,9,20,16,8,10,15,18,7,19,17],"yoast_head":"\nROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df - \u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173<\/title>\n<meta name=\"description\" content=\"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-\u76f4\u52a8\u5f0f\u7535\u78c1\u9600-20101-20108-\u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14-\u5316\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df - \u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173\" \/>\n<meta property=\"og:description\" content=\"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-\u76f4\u52a8\u5f0f\u7535\u78c1\u9600-20101-20108-\u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14-\u5316\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-12T08:39:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"400\" \/>\n\t<meta property=\"og:image:height\" content=\"336\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u5c48\u73cd18918650795\uff08\u5fae\u4fe1\u540c\u53f7\uff09\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/#website\",\"url\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/\",\"name\":\"\\u7535\\u78c1\\u9600 \\u89d2\\u5ea7\\u9600 \\u667a\\u80fd\\u5b9a\\u4f4d\\u5668 \\u76f4\\u52a8\\u5f0f\\u7535\\u78c1\\u9600 \\u5148\\u5bfc\\u5f0f\\u7535\\u78c1\\u9600 \\u624b\\u52a8\\u9600 \\u8109\\u51b2\\u9600 EHF-LM EHF-LO \\u7ebf\\u6027\\u8c03\\u5236 \\u7ebf\\u6027\\u5f00\\u5173 \\u65cb\\u8f6c\\u5f00\\u5173\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#primaryimage\",\"inLanguage\":\"zh-CN\",\"url\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png\",\"contentUrl\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png\",\"width\":400,\"height\":336},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#webpage\",\"url\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/\",\"name\":\"ROTEX Direct acting Solenoid valve \\u76f4\\u52a8\\u5f0f\\u7535\\u78c1\\u9600 20101 20108 \\u53ef\\u7528\\u4e8e\\u77f3\\u6cb9\\u548c\\u5929\\u7136\\u6c14 \\u5316\\u5de5 \\u706b\\u529b\\u53d1\\u7535 \\u6838\\u7535\\u7b49\\u9886\\u57df - \\u7535\\u78c1\\u9600 \\u89d2\\u5ea7\\u9600 \\u667a\\u80fd\\u5b9a\\u4f4d\\u5668 \\u76f4\\u52a8\\u5f0f\\u7535\\u78c1\\u9600 \\u5148\\u5bfc\\u5f0f\\u7535\\u78c1\\u9600 \\u624b\\u52a8\\u9600 \\u8109\\u51b2\\u9600 EHF-LM EHF-LO \\u7ebf\\u6027\\u8c03\\u5236 \\u7ebf\\u6027\\u5f00\\u5173 \\u65cb\\u8f6c\\u5f00\\u5173\",\"isPartOf\":{\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#primaryimage\"},\"datePublished\":\"2025-05-12T08:39:38+00:00\",\"dateModified\":\"2025-05-12T08:39:38+00:00\",\"author\":{\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/#\/schema\/person\/6d8a9b955941c41607eaa34b40bfd60c\"},\"description\":\"ROTEX Direct acting Solenoid valve \\u76f4\\u52a8\\u5f0f\\u7535\\u78c1\\u9600 20101 20108 \\u53ef\\u7528\\u4e8e\\u77f3\\u6cb9\\u548c\\u5929\\u7136\\u6c14 \\u5316\\u5de5 \\u706b\\u529b\\u53d1\\u7535 \\u6838\\u7535\\u7b49\\u9886\\u57df\",\"breadcrumb\":{\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\\u9996\\u9875\",\"item\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ROTEX Direct acting Solenoid valve \\u76f4\\u52a8\\u5f0f\\u7535\\u78c1\\u9600 20101 20108 \\u53ef\\u7528\\u4e8e\\u77f3\\u6cb9\\u548c\\u5929\\u7136\\u6c14 \\u5316\\u5de5 \\u706b\\u529b\\u53d1\\u7535 \\u6838\\u7535\\u7b49\\u9886\\u57df\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/#\/schema\/person\/6d8a9b955941c41607eaa34b40bfd60c\",\"name\":\"\\u5c48\\u73cd18918650795\\uff08\\u5fae\\u4fe1\\u540c\\u53f7\\uff09\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.bihec.com\/rotexautomationvalve\/#personlogo\",\"inLanguage\":\"zh-CN\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/14d4b93550da574d73963dcb342f7bd3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/14d4b93550da574d73963dcb342f7bd3?s=96&d=mm&r=g\",\"caption\":\"\\u5c48\\u73cd18918650795\\uff08\\u5fae\\u4fe1\\u540c\\u53f7\\uff09\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df - \u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173","description":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-\u76f4\u52a8\u5f0f\u7535\u78c1\u9600-20101-20108-\u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14-\u5316\/","og_locale":"zh_CN","og_type":"article","og_title":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df - \u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173","og_description":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df","og_url":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-\u76f4\u52a8\u5f0f\u7535\u78c1\u9600-20101-20108-\u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14-\u5316\/","og_site_name":"\u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173","article_published_time":"2025-05-12T08:39:38+00:00","og_image":[{"width":400,"height":336,"url":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u5c48\u73cd18918650795\uff08\u5fae\u4fe1\u540c\u53f7\uff09"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/#website","url":"https:\/\/www.bihec.com\/rotexautomationvalve\/","name":"\u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bihec.com\/rotexautomationvalve\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"zh-CN"},{"@type":"ImageObject","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#primaryimage","inLanguage":"zh-CN","url":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png","contentUrl":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-content\/uploads\/sites\/2185\/2025\/05\/img_6821b1a8e90a1.png","width":400,"height":336},{"@type":"WebPage","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#webpage","url":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/","name":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df - \u7535\u78c1\u9600 \u89d2\u5ea7\u9600 \u667a\u80fd\u5b9a\u4f4d\u5668 \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 \u5148\u5bfc\u5f0f\u7535\u78c1\u9600 \u624b\u52a8\u9600 \u8109\u51b2\u9600 EHF-LM EHF-LO \u7ebf\u6027\u8c03\u5236 \u7ebf\u6027\u5f00\u5173 \u65cb\u8f6c\u5f00\u5173","isPartOf":{"@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#primaryimage"},"datePublished":"2025-05-12T08:39:38+00:00","dateModified":"2025-05-12T08:39:38+00:00","author":{"@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/#\/schema\/person\/6d8a9b955941c41607eaa34b40bfd60c"},"description":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df","breadcrumb":{"@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/rotex-direct-acting-solenoid-valve-%e7%9b%b4%e5%8a%a8%e5%bc%8f%e7%94%b5%e7%a3%81%e9%98%80-20101-20108-%e5%8f%af%e7%94%a8%e4%ba%8e%e7%9f%b3%e6%b2%b9%e5%92%8c%e5%a4%a9%e7%84%b6%e6%b0%94-%e5%8c%96\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.bihec.com\/rotexautomationvalve\/"},{"@type":"ListItem","position":2,"name":"ROTEX Direct acting Solenoid valve \u76f4\u52a8\u5f0f\u7535\u78c1\u9600 20101 20108 \u53ef\u7528\u4e8e\u77f3\u6cb9\u548c\u5929\u7136\u6c14 \u5316\u5de5 \u706b\u529b\u53d1\u7535 \u6838\u7535\u7b49\u9886\u57df"}]},{"@type":"Person","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/#\/schema\/person\/6d8a9b955941c41607eaa34b40bfd60c","name":"\u5c48\u73cd18918650795\uff08\u5fae\u4fe1\u540c\u53f7\uff09","image":{"@type":"ImageObject","@id":"https:\/\/www.bihec.com\/rotexautomationvalve\/#personlogo","inLanguage":"zh-CN","url":"https:\/\/secure.gravatar.com\/avatar\/14d4b93550da574d73963dcb342f7bd3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/14d4b93550da574d73963dcb342f7bd3?s=96&d=mm&r=g","caption":"\u5c48\u73cd18918650795\uff08\u5fae\u4fe1\u540c\u53f7\uff09"}}]}},"_links":{"self":[{"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/posts\/222"}],"collection":[{"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/users\/37"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/comments?post=222"}],"version-history":[{"count":1,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/posts\/222\/revisions"}],"predecessor-version":[{"id":226,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/posts\/222\/revisions\/226"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/media\/225"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/media?parent=222"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/categories?post=222"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/rotexautomationvalve\/wp-json\/wp\/v2\/tags?post=222"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}