{"id":231,"date":"2025-01-06T10:24:16","date_gmt":"2025-01-06T02:24:16","guid":{"rendered":"https:\/\/www.bihec.com\/soha-tech-co2-sensor\/?p=231"},"modified":"2025-01-06T10:24:16","modified_gmt":"2025-01-06T02:24:16","slug":"soha-tech%e4%ba%8c%e6%b0%a7%e5%8c%96%e7%a2%b3%e3%80%81%e6%b8%a9%e5%ba%a6%e5%92%8c%e6%b9%bf%e5%ba%a6%e5%8f%98%e9%80%81%e5%99%a8sh-vt260","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/soha-tech-co2-sensor\/soha-tech%e4%ba%8c%e6%b0%a7%e5%8c%96%e7%a2%b3%e3%80%81%e6%b8%a9%e5%ba%a6%e5%92%8c%e6%b9%bf%e5%ba%a6%e5%8f%98%e9%80%81%e5%99%a8sh-vt260\/","title":{"rendered":"SOHA TECH\u4e8c\u6c27\u5316\u78b3\u3001\u6e29\u5ea6\u548c\u6e7f\u5ea6\u53d8\u9001\u5668SH-VT260"},"content":{"rendered":"
\u5b83\u662f\u4e00\u6b3e\u4e8c\u6c27\u5316\u78b3\u3001\u6e29\u5ea6\u548c\u6e7f\u5ea6\u53d8\u9001\u5668\uff0c\u914d\u6709\u9ad8\u6027\u80fd\u53cc\u4e8c\u6c27\u5316\u78b3\u4f20\u611f\u5668\uff0c\u9488\u5bf9\u957f\u671f\u4f7f\u7528\u548c\u4f5c\u7269\u79cd\u690d\u8fdb\u884c\u4e86\u4f18\u5316<\/p>\n
<\/p>\n
<\/p>\n
1. \u4e8c\u6c27\u5316\u78b3\u4f20\u611f\u5668<\/strong><\/p>\n <\/p>\n 2. \u6e29\u5ea6\u611f\u5e94\u5668<\/strong><\/p>\n <\/p>\n 3. \u6e7f\u5ea6\u4f20\u611f\u5668<\/strong><\/p>\n Analog<\/td>\n<\/tr>\n <\/p>\n <\/p>\n <\/p>\n\n\n
\n List<\/td>\n Contents<\/td>\n Remarks<\/td>\n<\/tr>\n \n Measuring method<\/td>\n Dual Light Wavelength NDIR<\/td>\n <\/td>\n<\/tr>\n \n Measuring Range<\/td>\n 0~3000\/5000\/10,000 ppm<\/td>\n option<\/td>\n<\/tr>\n \n Accuracy<\/td>\n \u00b13% measured value<\/td>\n @0~50\u2103<\/td>\n<\/tr>\n \n Response time<\/td>\n 0 ~ 80% < 30 Sec<\/td>\n <\/td>\n<\/tr>\n \n Signal update term<\/td>\n Every 2.0 Seconds<\/td>\n <\/td>\n<\/tr>\n \n Warm-up Time<\/td>\n @25\u2103 < 90Sec<\/td>\n <\/td>\n<\/tr>\n \n Working Temp<\/td>\n -10 ~ 50\u2103<\/td>\n <\/td>\n<\/tr>\n \n Working Humidity<\/td>\n 0 ~ 99.5% RH<\/td>\n Noncondensing
\ncondition<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n\n
\n List<\/td>\n Contents<\/td>\n Remarks<\/td>\n<\/tr>\n \n Measuring Range<\/td>\n -25 ~ 85\u2103
\n-10 ~ 50\u2103<\/td>\n(RS485)<\/td>\n<\/tr>\n \n -10.0 ~ 50.0\u2103<\/td>\n (Analog)<\/td>\n<\/tr>\n \n Accuracy<\/td>\n \u00b10.3\u2103<\/td>\n Max. \u00b10.4 \u2103<\/td>\n<\/tr>\n \n Response Time<\/td>\n 0~30 sec<\/td>\n <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n \n\n
\n List<\/td>\n Contents<\/td>\n Remarks<\/td>\n<\/tr>\n \n Measuring Range<\/td>\n 0 ~ 99.9 %RH<\/td>\n RS-485<\/p>\n \n Accuracy<\/td>\n \u00b12 %RH<\/td>\n <\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n