{"id":397794,"date":"2024-12-05T22:34:14","date_gmt":"2024-12-05T14:34:14","guid":{"rendered":"https:\/\/www.bihec.com\/teca\/?p=397794"},"modified":"2024-12-05T22:34:15","modified_gmt":"2024-12-05T14:34:15","slug":"lhp-1800cpv-liquid-cooled-thermoelectric-cold-plate-for-laboratory","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/teca\/lhp-1800cpv-liquid-cooled-thermoelectric-cold-plate-for-laboratory\/","title":{"rendered":"\u7f8e\u56fdTECA \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u51b7\u677f LHP-1800CPV \u51b7\u76d8\u3001\u70ed\u7535\u51b7\u677f \u3001\u534a\u5bfc\u4f53\u5236\u51b7\u5668\u3001\u534a\u5bfc\u4f53\u5236\u51b7\u677f\u3001\u534a\u5bfc\u4f53\u5236\u51b7\u76d8 TECA\u8fdb\u53e3\u4ee3\u7406"},"content":{"rendered":"

\"\"<\/p>\n

TECA LHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a><\/h2>\n

Liquid Cooled Thermoelectric Cold Plate For Laboratory<\/h3>\n

TECA<\/a> LHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\u7279\u70b9\uff1a<\/h4>\n

\u7cbe\u5bc6\u52a0\u5de5\u7684\u9633\u6781\u6c27\u5316\u94dd\u51b7\u677f<\/a>\u8868\u9762
\n\u6613\u4e8e\u6e05\u6d01\u7684\u4e0d\u9508\u94a2\u56f4\u88d9
\n\u51b7\u5374\u548c\u52a0\u70ed(-30\u6444\u6c0f\u5ea6\u81f390\u6444\u6c0f\u5ea6\u548c130\u6444\u6c0f\u5ea6)
\n\u8584\u578b\u8bbe\u8ba1\uff0c\u7b26\u5408\u4eba\u4f53\u5de5\u7a0b\u5b66\u7684\u503e\u659c\u6b63\u9762
\n\u6613\u4e8e\u63a5\u8fd1\u7684\u51b7\u5374\u6db2\u7aef\u53e3
\n\u91cd\u91cf\u4e0d\u523055\u78c5\u3002(25\u516c\u65a4)
\n\u53f0\u5f0f\u88c5\u7f6e\uff0c\u5360\u5730\u9762\u79ef15.2\u82f1\u5bf8X 19.2\u82f1\u5bf8
\n\u51e0\u4e4e\u514d\u7ef4\u62a4\u8fd0\u884c
\n\u6d82\u6f06\u642a\u74f7\u4e0d\u9508\u94a2\u5916\u58f3
\n\u63d0\u4f9b\u4e0d\u9508\u94a2\u87ba\u7eb9\u63d2\u4ef6
\n\u53ef\u52a0\u5de5\u7684\u7279\u5f81\u677f\u548c\u76d6\u9644\u4ef6<\/p>\n

TECA LHP-1800CPV<\/a> \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\u8ba2\u8d27\u53f7\uff1a<\/h4>\n\n\n\n\n\n\n\n<\/colgroup>\n\n\n\n\n\n\n\n\n\n
MODEL\u00a0<\/span><\/th>\n\u8d27\u53f7<\/span><\/th>\n\u51b7\u677f\u8868\u9762<\/span><\/th>\n\u7535\u538b
\nVAC (VDC)<\/span><\/th>\n
\u7535\u6d41
\nAMPS<\/span><\/th>\n
\u51b7\u677f\u6e29\u5ea6\u8303\u56f4 \u00b0C<\/span><\/th>\n<\/tr>\n<\/thead>\n
LHP-1800CPV<\/a><\/td>\n3-05KB-1-0A0<\/a><\/td>\nSmooth surface<\/td>\n240<\/td>\n8<\/td>\n-30 \/ +90<\/td>\n<\/tr>\n
LHP-1800CPV<\/td>\n3-05KB-1-TAP<\/td>\n6-32 Tap pattern<\/td>\n240<\/td>\n8<\/td>\n-30 \/ +90<\/td>\n<\/tr>\n
LHP-1800CPV<\/td>\n3-05KB-1-MET<\/td>\nM3 Tap pattern<\/td>\n240<\/td>\n8<\/td>\n-30\/ +90<\/td>\n<\/tr>\n
LHP-1800CPV<\/td>\n3-05KB-6-0A0<\/a><\/td>\nSmooth surface<\/td>\n240<\/td>\n8<\/td>\n-30 \/ +120<\/td>\n<\/tr>\n
LHP-1800CPV<\/td>\n3-05KB-6-TAP<\/td>\n6-32 Tap pattern<\/td>\n240<\/td>\n8<\/td>\n-30 \/ +120<\/td>\n<\/tr>\n
LHP-1800CPV<\/td>\n3-05KB-6-MET<\/td>\nM3 Tap pattern<\/td>\n240<\/td>\n8<\/td>\n-30 \/ +120<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

\"\"<\/p>\n

TECA LHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\u89c4\u683c\u53c2\u6570\uff1a<\/h4>\n
\n
\n

\u98ce\u683c:<\/strong>\u5b9e\u9a8c\u5ba4\u5de5\u4f5c\u53f0
\n\u7535\u538b:<\/strong>240\u4f0f\u4ea4\u6d41\u7535
\n\u5f53\u524d:<\/strong>8\u5b89\u57f9
\n\u5de5\u4f5c\u73af\u5883:<\/strong>0\/+50\u6444\u6c0f\u5ea6<\/p>\n<\/div>\n

\n

\u7ee9\u6548\u8bc4\u7ea7:<\/strong>
\n\u51b7\u5374\u80fd\u529b:<\/strong>800\u74e6
\n\u51b7\u5374COP:<\/strong>\u00a00.42
\n\u52a0\u70ed\u80fd\u529b:<\/strong>1900\u74e6
\n\u6700\u5c0f\u51b7\u5374\u6db2\u6d41\u91cf:<\/strong>1\u5347\/\u5206\u949f<\/p>\n<\/div>\n<\/div>\n

\n
\n

\u5305\u62ec:<\/strong>
\n\u96c6\u6210\u7535\u6e90
\n\u96c6\u6210PWM\u6e29\u5ea6\u63a7\u5236
\nUSB\u901a\u4fe1\u7aef\u53e3
\n\u8fdc\u7a0b\u654f\u611f\u6027<\/p>\n<\/div>\n

\n

\u63a7\u5236\u5668\u7279\u6027:<\/strong>
\n\u96c6\u6210\u201c\u53ef\u8c03\u201dPWM\u6e29\u5ea6\u63a7\u5236
\nPWM\u53cc\u5411\u6e29\u5ea6\u63a7\u5236
\n\u5177\u67094\u4e2a\u72ec\u7acbPID\u8bbe\u7f6e\u76844\u4e2a\u6e29\u5ea6\u533a
\n\u591a\u6bb5\u659c\u5761\u548c\u6d78\u6ce1\u53ef\u7f16\u7a0b
\n\u5185\u90e8RTD\u4f20\u611f\u5668
\nRemote Sensibility\u53ef\u5207\u6362\u81f3\u5916\u90e8\u9644\u4ef6RTD\u4f20\u611f\u5668
\n\u4f7f\u7528\u6613\u4e8e\u4f7f\u7528\u7684\u8f6f\u4ef6\u8fdb\u884cUSB\u901a\u4fe1
\nLabview VI\u793a\u4f8b<\/p>\n<\/div>\n<\/div>\n

\"\"<\/p>\n

3-05KB-1-0A0<\/a>\n3-05KB-6-0A0<\/a>\nLHP-1800CPV<\/a>\nLHP-1800CPV 3-05KB-1-0A0<\/a>\nLHP-1800CPV 3-05KB-6-0A0<\/a>\nLHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\nTECA<\/a>\nTECA LHP-1800CPV<\/a>\nTECA LHP-1800CPV \u51b7\u76d8<\/a>\nTECA LHP-1800CPV \u534a\u5bfc\u4f53\u5236\u51b7\u5668<\/a>\nTECA LHP-1800CPV \u534a\u5bfc\u4f53\u5236\u51b7\u677f<\/a>\nTECA LHP-1800CPV \u534a\u5bfc\u4f53\u5236\u51b7\u76d8<\/a>\nTECA LHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\nTECA LHP-1800CPV \u70ed\u7535\u51b7\u677f<\/a>\nTECA\u8fdb\u53e3\u4ee3\u7406<\/a>\nThermoElectric Cooling America Corporation.<\/a>\n\u51b7\/\u70ed\u677f<\/a>\n\u51b7\u677f<\/a>\n\u51b7\u76d8<\/a>\n\u534a\u5bfc\u4f53\u5236\u51b7\u5668<\/a>\n\u534a\u5bfc\u4f53\u5236\u51b7\u677f<\/a>\n\u534a\u5bfc\u4f53\u5236\u51b7\u76d8<\/a>\n\u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\n\u6db2\u51b7\u70ed\u7535\u51b7\u677f<\/a>\n\u70ed\u7535\u51b7\u677f<\/a>\n\u7a7a\u51b7\u70ed\u7535\u51b7\u677f<\/a>\n\u7a7a\u8c03\u51b7\u677f<\/a>\n\u7f8e\u56fdTECA<\/a>\n\u7f8e\u56fd TECA<\/a><\/div>","protected":false},"excerpt":{"rendered":"

TECA LHP-1800CPV \u5b9e\u9a8c\u5ba4\u7528\u6db2\u51b7\u70ed\u7535\u51b7\u677f Liquid Cooled Thermoelectric Cold Plate For Laboratory TECA LH <\/p>\n","protected":false},"author":22,"featured_media":397795,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[109,408,23,20],"tags":[633,635,293,632,634,631,29,630,640,638,637,636,629,639,504,400,450,412,515,121,561,170,292,272,60,452,312,482,118],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/posts\/397794"}],"collection":[{"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/comments?post=397794"}],"version-history":[{"count":2,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/posts\/397794\/revisions"}],"predecessor-version":[{"id":397799,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/posts\/397794\/revisions\/397799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/media\/397795"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/media?parent=397794"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/categories?post=397794"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/teca\/wp-json\/wp\/v2\/tags?post=397794"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}