{"id":639496,"date":"2016-02-05T09:12:12","date_gmt":"2016-02-05T01:12:12","guid":{"rendered":"http:\/\/www.jinkoucaigou.com\/?p=639496"},"modified":"2016-02-05T09:12:12","modified_gmt":"2016-02-05T01:12:12","slug":"f-414-c-compression-load-cell-tension-tensioncompression-single-column-max-500-kn","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/tme\/f-414-c-compression-load-cell-tension-tensioncompression-single-column-max-500-kn\/","title":{"rendered":"F 414 C Compression load cell \/ tension \/ tension\/compression \/ single-column max. 500 kN"},"content":{"rendered":"

Compression load cell \/ tension \/ tension\/compression \/ single-column max. 500 kN | F 414 C \u538b\u7f29\u8d1f\u8377\u7ec6\u80de\/\u62c9\/\u62c9\/\u538b\/\u5355\u67f1\u6700\u5927500\u5343\u725b| F 414 C
Compression load cell \/ tension \/ tension\/compression \/ single-column max. 500 kN | F 414 C \u538b\u7f29\u8d1f\u8377\u7ec6\u80de\/\u62c9\/\u62c9\/\u538b\/\u5355\u67f1\u6700\u5927500\u5343\u725b| F 414 C<\/p>\n

Characteristics
\u7279\u70b9
Type:
\u7c7b\u578b\uff1a
compression, tension, tension\/compression
\u538b\u7f29\uff0c\u62c9\u4f38\uff0c\u62c9\u4f38\/\u538b\u7f29
Form:
\u5f62\u5f0f\uff1a
single-column
\u5355\u67f1
Other characteristics:
\u5176\u4ed6\u7279\u70b9\uff1a
miniature
\u5fae\u578b
Description
\u63cf\u8ff0
Sensitivity creep on compensated range \t\/\u00b0C \t \/- 0.02
\u8865\u507f\u8303\u56f4\u5185\u7684\u654f\u611f\u6027\u8815\u53d8- 0.02
Zero creep on compensated range \t\/\u00b0C \t \/- 0.015
\u8865\u507f\u8303\u56f4\u4e3a\u96f6\u7684\u96f6\u8815\u53d8- 0.015
Initial imbalance \t \t 1000 under 40 V
\u521d\u59cb\u4e0d\u5e73\u886140\u4e0b1000\u4f0f
Material \t\tStainless steel
\u6750\u8d28\u4e0d\u9508\u94a2
Sensitivity at full range \tmV\/V \t1.5
\u5728\u5168\u91cf\u7a0b\u4e2d\u538b\/ 1.5\u7684\u7075\u654f\u5ea6
Safe overload \t \t150
\u5b89\u5168\u8d85\u8f7d150
Operating temperature \t\u00b0C \t-20 to 100 (-4\u00b0F to 210\u00b0F)
\u64cd\u4f5c\u6e29\u5ea6\u4e3a20\uff5e100\uff084\u00b0\uff5e210\u00b0\uff09
Compensated temperature \t\u00b0C \t 10 to 70 (50\u00b0F to 160\u00b0F)
\u8865\u507f\u6e29\u5ea6\u4e3a10\uff5e70\uff0850\u00b0\uff5e160\u00b0\uff09
Excitation voltage \tV \t10
\u52b1\u78c1\u7535\u538b10<\/p>\n

Compression load cell \/ tension \/ tension\/compression \/ single-column max. 500 kN | F 414 C \u538b\u7f29\u8d1f\u8377\u7ec6\u80de\/\u62c9\/\u62c9\/\u538b\/\u5355\u67f1\u6700\u5927500\u5343\u725b| F 414 C<\/strong><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

Compression load cell \/ tension \/ tension\/compression \/ single-column max. 500 kN | F 414 <\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":[],"categories":[3],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/posts\/639496"}],"collection":[{"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/comments?post=639496"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/posts\/639496\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/media?parent=639496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/categories?post=639496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/tme\/wp-json\/wp\/v2\/tags?post=639496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}