{"id":14120,"date":"2014-09-09T17:40:43","date_gmt":"2014-09-09T09:40:43","guid":{"rendered":"http:\/\/www.bihec.com\/?p=1053"},"modified":"2014-09-09T17:40:43","modified_gmt":"2014-09-09T09:40:43","slug":"%e7%be%8e%e5%9b%bd-intek-%e5%85%ac%e5%8f%b8-111d-xd-tu116hcss%c2%bcswag-420-isb-220v-flow-meter%e6%b5%81%e9%87%8f%e8%ae%a1-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/intek-inc\/%e7%be%8e%e5%9b%bd-intek-%e5%85%ac%e5%8f%b8-111d-xd-tu116hcss%c2%bcswag-420-isb-220v-flow-meter%e6%b5%81%e9%87%8f%e8%ae%a1-2\/","title":{"rendered":"111D-XD-TU1\/16(HC)(SS)(\u00bc"SWAG)-4\/20-ISB-220V flow meter\u6d41\u91cf\u8ba1"},"content":{"rendered":"

\n\tConsisting of flow sensing transducer, separate electronics package, and interconnect cable <\/span><\/p>\n

\t Same as Serial Number 94124-4 <\/span><\/p>\n

\t Flow Data\uff1a <\/span><\/p>\n

\t Fluid: 98% Sulfuric Acid (See Note 1) <\/span><\/p>\n

\t Customer Line Size: Same as Previous <\/span><\/p>\n

\t Customer Flow Range: 0-0.36 lph <\/span><\/p>\n

\t Calibrated Flow Range: 0.036-0.36 lph <\/span><\/p>\n

\t Temperature-Max: 60 C <\/span><\/p>\n

\t Temperature-Operating Range: 38 C <\/span><\/p>\n

\t Pressure-Max: 1 mPag <\/span><\/p>\n

\t Pressure-Operating range: 0.11 mPag <\/span><\/p>\n

\t Viscosity: – <\/span><\/p>\n

\t Specific Gravity: 1.818 <\/span><\/p>\n

\t Instrument Data\uff1a <\/span><\/p>\n

\t Transducer Type: TU <\/span><\/p>\n

\t Wetted Material: Hastelloy-C276 (See Note 2) <\/span><\/p>\n

\t Shell Material: Stainless Steel <\/span><\/p>\n

\t Fittings: 1\/4-inch HC276 Swagelok fittings <\/span><\/p>\n

\t Local Display: Flow Rate <\/span><\/p>\n

\t Calibration Units: lph <\/span><\/p>\n

\t Output(s): linear 4 to 20 milliamp <\/span><\/p>\n

\t Input Power: 220 VAC 50 Hz <\/span><\/p>\n

\t Electronics Enclosure: None – Mounting Plate Only <\/span><\/p>\n

\t Cable Length: 10 ft; up to 200 ft available at \uffe528.00\/ft <\/span><\/p>\n

\t Notes\uff1a <\/span><\/p>\n

\t 1. Intek may use a substitute calibration fluid while calibrating your instrument. <\/span><\/p>\n

\t If this is the case, a simple field calibration adjustment will be necessary to guarantee the highest levels of accuracy. <\/span><\/p>\n

\t 2. The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Intek, Inc. <\/span><\/p>\n

\t makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.<\/span><\/span><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

Consisting of flow s…<\/p>\n","protected":false},"author":1,"featured_media":1039,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[578],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14120"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=14120"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14120\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media\/1039"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=14120"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=14120"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=14120"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}