{"id":14126,"date":"2015-05-19T17:58:19","date_gmt":"2015-05-19T09:58:19","guid":{"rendered":"http:\/\/www.bihec.com\/?p=2447"},"modified":"2015-05-19T17:58:19","modified_gmt":"2015-05-19T09:58:19","slug":"bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/","title":{"rendered":"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668"},"content":{"rendered":"

\u6700\u5927\u7075\u654f\u5ea6\u8303\u56f4\uff1a800\u00a0pC<\/b>
\n\u6700\u5c0f\u7075\u654f\u5ea6\u8303\u56f4\uff1a400\u00a0pC<\/b>
\n\u566a\u58f0\uff1a0.55\u00a0pCrms\uff0c\u00a0\u53d7\u9650\u4e8e\u52a8\u6001\u8303\u56f4<\/b>
\n\u52a8\u6001\u8303\u56f4\uff1a\uff1e\u00a035000\uff0c\u53d7\u9650\u4e8e\u5206\u8fa8\u7387<\/b>
\n\u8f93\u51fa\uff1a\u00b18v<\/b>
\n\u89e6\u53d1\uff1aTTL,\u00a0\u226510\u00a0ns<\/b>
\n\u89e6\u53d1\u9891\u7387\uff1a20kHZ<\/b>
\n\u6821\u51c6\u8109\u51b2\uff1a1\u00a0pC\uff0c10pC\uff0c100pC\uff0c1nC\u00a0\uff0c\u7cbe\u5ea6\u00b12%<\/b>
\n\u7535\u6e90\uff1a\u00b115\u00a0vdc\uff0c2\u00d7400mA\uff0c\u00a0\u7ebf\u6027<\/b><\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

\u6700\u5927\u7075\u654f\u5ea6\u8303\u56f4\uff1a800\u00a0pC \u6700\u5c0f\u7075\u654f\u5ea6…<\/p>\n","protected":false},"author":1,"featured_media":2448,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[86],"tags":[],"yoast_head":"\nIntegrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation\u516c\u53f8integrating-ct-beam-charge-monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668-2\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1\" \/>\n<meta property=\"og:description\" content=\"\u6700\u5927\u7075\u654f\u5ea6\u8303\u56f4\uff1a800\u00a0pC \u6700\u5c0f\u7075\u654f\u5ea6…\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation\u516c\u53f8integrating-ct-beam-charge-monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668-2\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1\" \/>\n<meta property=\"article:published_time\" content=\"2015-05-19T09:58:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\u56fe\u72475.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"272\" \/>\n\t<meta property=\"og:image:height\" content=\"245\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.bihec.com\/#website\",\"url\":\"https:\/\/www.bihec.com\/\",\"name\":\"\\u7695\\u8d6b\\u56fd\\u9645-\\u5728\\u7ebf\\u7c98\\u5ea6\\u8ba1-\\u4fbf\\u643a\\u5f0f\\u7c98\\u5ea6\\u8ba1\",\"description\":\"\\u6bdb\\u7ec6\\u7ba1\\u7c98\\u5ea6\\u8ba1 \\u5728\\u7ebf\\u5bc6\\u5ea6\\u8ba1 \\u4fbf\\u643a\\u5f0f\\u5bc6\\u5ea6\\u8ba1 \\u7c89\\u4f53\\u6d41\\u53d8\\u4eea CD\\u5706\\u4e8c\\u8272\\u5149\\u8c31\\u4eea CPL\\u5706\\u504f\\u632f\\u8367\\u5149\\u5149\\u8c31\\u4eea \\u611f\\u5e94\\u52a0\\u70ed\\u5668 \\u7535\\u5b50\\u67aa \\u8868\\u9762\\u5f20\\u529b\\u4eea UIC\\u78b3\\u786b\\u5206\\u6790\\u4eea \\u5bfc\\u70ed\\u7cfb\\u6570\\u4eea \\u6fc0\\u5149\\u51c6\\u76f4\\u4eea\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.bihec.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#primaryimage\",\"inLanguage\":\"zh-CN\",\"url\":\"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\\u56fe\\u72475.jpg\",\"contentUrl\":\"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\\u56fe\\u72475.jpg\",\"width\":272,\"height\":245,\"caption\":\"Bergoz Instrumentation\\u516c\\u53f8Integrating CT & Beam Charge Monitor\\u675f\\u6d41\\u653e\\u7535\\u76d1\\u6d4b\\u5668\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#webpage\",\"url\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/\",\"name\":\"Integrating CT & Beam Charge Monitor\\u675f\\u6d41\\u653e\\u7535\\u76d1\\u6d4b\\u5668 - \\u7695\\u8d6b\\u56fd\\u9645-\\u5728\\u7ebf\\u7c98\\u5ea6\\u8ba1-\\u4fbf\\u643a\\u5f0f\\u7c98\\u5ea6\\u8ba1\",\"isPartOf\":{\"@id\":\"https:\/\/www.bihec.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#primaryimage\"},\"datePublished\":\"2015-05-19T09:58:19+00:00\",\"dateModified\":\"2015-05-19T09:58:19+00:00\",\"author\":{\"@id\":\"https:\/\/www.bihec.com\/#\/schema\/person\/0bbff104a4fcdf3fa828d71b45581611\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\\u9996\\u9875\",\"item\":\"https:\/\/www.bihec.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Integrating CT & Beam Charge Monitor\\u675f\\u6d41\\u653e\\u7535\\u76d1\\u6d4b\\u5668\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.bihec.com\/#\/schema\/person\/0bbff104a4fcdf3fa828d71b45581611\",\"name\":\"\\u5ba2\\u670d\\u70ed\\u7ebf\\uff1a400-840-1510\",\"description\":\"\\u7535\\u8bdd\\uff1a400-840-1510 \\u4f20\\u771f\\uff1a021-51062822 Email\\uff1ainfo@bihec.com\",\"url\":\"https:\/\/www.bihec.com\/author\/bihec-2\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation\u516c\u53f8integrating-ct-beam-charge-monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668-2\/","og_locale":"zh_CN","og_type":"article","og_title":"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","og_description":"\u6700\u5927\u7075\u654f\u5ea6\u8303\u56f4\uff1a800\u00a0pC \u6700\u5c0f\u7075\u654f\u5ea6…","og_url":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation\u516c\u53f8integrating-ct-beam-charge-monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668-2\/","og_site_name":"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","article_published_time":"2015-05-19T09:58:19+00:00","og_image":[{"width":272,"height":245,"url":"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\u56fe\u72475.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.bihec.com\/#website","url":"https:\/\/www.bihec.com\/","name":"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","description":"\u6bdb\u7ec6\u7ba1\u7c98\u5ea6\u8ba1 \u5728\u7ebf\u5bc6\u5ea6\u8ba1 \u4fbf\u643a\u5f0f\u5bc6\u5ea6\u8ba1 \u7c89\u4f53\u6d41\u53d8\u4eea CD\u5706\u4e8c\u8272\u5149\u8c31\u4eea CPL\u5706\u504f\u632f\u8367\u5149\u5149\u8c31\u4eea \u611f\u5e94\u52a0\u70ed\u5668 \u7535\u5b50\u67aa \u8868\u9762\u5f20\u529b\u4eea UIC\u78b3\u786b\u5206\u6790\u4eea \u5bfc\u70ed\u7cfb\u6570\u4eea \u6fc0\u5149\u51c6\u76f4\u4eea","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bihec.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"zh-CN"},{"@type":"ImageObject","@id":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#primaryimage","inLanguage":"zh-CN","url":"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\u56fe\u72475.jpg","contentUrl":"https:\/\/www.bihec.com\/wp-content\/uploads\/2015\/05\/\u56fe\u72475.jpg","width":272,"height":245,"caption":"Bergoz Instrumentation\u516c\u53f8Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668"},{"@type":"WebPage","@id":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#webpage","url":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/","name":"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","isPartOf":{"@id":"https:\/\/www.bihec.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#primaryimage"},"datePublished":"2015-05-19T09:58:19+00:00","dateModified":"2015-05-19T09:58:19+00:00","author":{"@id":"https:\/\/www.bihec.com\/#\/schema\/person\/0bbff104a4fcdf3fa828d71b45581611"},"breadcrumb":{"@id":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.bihec.com\/bergoz-instrumentation\/bergoz-instrumentation%e5%85%ac%e5%8f%b8integrating-ct-beam-charge-monitor%e6%9d%9f%e6%b5%81%e6%94%be%e7%94%b5%e7%9b%91%e6%b5%8b%e5%99%a8-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.bihec.com\/"},{"@type":"ListItem","position":2,"name":"Integrating CT & Beam Charge Monitor\u675f\u6d41\u653e\u7535\u76d1\u6d4b\u5668"}]},{"@type":"Person","@id":"https:\/\/www.bihec.com\/#\/schema\/person\/0bbff104a4fcdf3fa828d71b45581611","name":"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510","description":"\u7535\u8bdd\uff1a400-840-1510 \u4f20\u771f\uff1a021-51062822 Email\uff1ainfo@bihec.com","url":"https:\/\/www.bihec.com\/author\/bihec-2\/"}]}},"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14126"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=14126"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14126\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media\/2448"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=14126"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=14126"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=14126"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}