{"id":14320,"date":"2018-06-22T15:18:20","date_gmt":"2018-06-22T07:18:20","guid":{"rendered":"http:\/\/www.bihec.com\/?p=14320"},"modified":"2018-06-22T15:18:20","modified_gmt":"2018-06-22T07:18:20","slug":"auto-titration-kf-analysis-%e8%87%aa%e5%8a%a8%e6%bb%b4%e5%ae%9a%e5%92%8c-kf-%e5%88%86%e6%9e%90","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/zz\/auto-titration-kf-analysis-%e8%87%aa%e5%8a%a8%e6%bb%b4%e5%ae%9a%e5%92%8c-kf-%e5%88%86%e6%9e%90\/","title":{"rendered":"Auto-Titration & KF Analysis \u81ea\u52a8\u6ef4\u5b9a\u548c KF \u5206\u6790"},"content":{"rendered":"
<\/p>\n
The 12 series of Automated Titration performs the fundamental task of titration where the concentration of a chemical substance is determined by reacting it with a measured amount of another chemical. The Auto Titrator performs this analysis using a motor driven dispenser, stirred reaction vessel and electrodes which sense the completion of the reaction by measuring the potential difference between two electrodes.<\/p>\n
12\u7cfb\u5217\u81ea\u52a8\u6ef4\u5b9a\u5b8c\u6210\u4e86\u6ef4\u5b9a\u7684\u57fa\u672c\u4efb\u52a1\uff0c\u5176\u4e2d\u4e00\u79cd\u5316\u5b66\u7269\u8d28\u7684\u6d53\u5ea6\u662f\u901a\u8fc7\u4e0e\u53e6\u4e00\u79cd\u5316\u5b66\u7269\u8d28\u7684\u6d4b\u5b9a\u91cf\u53cd\u5e94\u6765\u786e\u5b9a\u7684\u3002\u81ea\u52a8\u6ef4\u5b9a\u5668\u4f7f\u7528\u7535\u673a\u9a71\u52a8\u7684\u5206\u914d\u5668\u3001\u6405\u62cc\u53cd\u5e94\u5bb9\u5668\u548c\u7535\u6781\u8fdb\u884c\u8fd9\u4e00\u5206\u6790\uff0c\u901a\u8fc7\u6d4b\u91cf\u4e24\u4e2a\u7535\u6781\u4e4b\u95f4\u7684\u7535\u4f4d\u5dee\u6765\u611f\u77e5\u53cd\u5e94\u7684\u5b8c\u6210\u3002<\/p>\n
The 12 series of Automatic Titration systems offers the following modes of analysis:12\u7cfb\u5217\u81ea\u52a8\u6ef4\u5b9a\u7cfb\u7edf\u63d0\u4f9b\u4ee5\u4e0b\u5206\u6790\u6a21\u5f0f\uff1a<\/p>\n
INCREMENTAL \u2013 This method operates with a user selectable fixed dose and fixed intervals until the end point is detected or volume limit is reached.\u589e\u91cf-\u8be5\u65b9\u6cd5\u4f7f\u7528\u7528\u6237\u53ef\u9009\u62e9\u7684\u56fa\u5b9a\u5242\u91cf\u548c\u56fa\u5b9a\u95f4\u9694\uff0c\u76f4\u5230\u68c0\u6d4b\u5230\u7ec8\u70b9\u6216\u8fbe\u5230\u4f53\u79ef\u6781\u9650\u4e3a\u6b62\u3002<\/p>\n
EQUILIBRIUM \u2013 This is the Universal and Dynamic Titration. In this titration the dose and time automatically are tuned to the titration trend with evaluation of the end point.\u00a0\u5e73\u8861\u2014\u2014\u8fd9\u662f\u4e00\u79cd\u901a\u7528\u7684\u52a8\u6001\u6ef4\u5b9a\u6cd5\u3002\u5728\u8fd9\u4e2a\u6ef4\u5b9a\u4e2d\uff0c\u5242\u91cf\u548c\u65f6\u95f4\u81ea\u52a8\u5730\u968f\u7740\u6ef4\u5b9a\u7ec8\u70b9\u7684\u8bc4\u4ef7\u800c\u8c03\u8c10\u5230\u6ef4\u5b9a\u8d8b\u52bf\u3002<\/p>\n
pH CUT OFF\/STAT \u2013 in pH cut off mode the end point is determined in a pre-selectable pH window. In pH-STAT mode the pH value is maintained until the pre-selected time interval is reached. PH\u622a\u6b62\/ STAT -\u5728pH\u622a\u6b62\u6a21\u5f0f\u4e0b\uff0c\u7ec8\u70b9\u53ef\u5728\u9884\u5148\u9009\u62e9\u7684pH\u7a97\u53e3\u4e2d\u786e\u5b9a\u3002\u5728pH-STAT\u6a21\u5f0f\u4e0b\uff0c\u4fdd\u6301pH\u503c\u76f4\u5230\u8fbe\u5230\u9884\u5148\u9009\u5b9a\u7684\u65f6\u95f4\u95f4\u9694<\/p>\n
<\/p>\n
SPECIFICATIONS<\/td>\n | <\/td>\n<\/tr>\n | ||||||||
Principle<\/td>\n | Volume determination by equivilent point, end point or pH STAT<\/td>\n<\/tr>\n | ||||||||
Control<\/td>\n | Microprocessor based<\/td>\n<\/tr>\n | ||||||||
mV Range<\/td>\n | =\/- 3200mV<\/td>\n<\/tr>\n | ||||||||
Accuracy<\/td>\n | +\/- 0.1mV (+\/- 0.0016pH)<\/td>\n<\/tr>\n | ||||||||
Amplifier Input Impedance<\/td>\n | >1012<\/sup> Ohms<\/td>\n<\/tr>\nBurette Resolution<\/td>\n | 1\/5000 for 5ml, 1\/10000 for 10ml, 1\/5000 for 25ml<\/td>\n<\/tr>\n | Filing Time<\/td>\n | <20 Seconds<\/td>\n<\/tr>\n | Keyboard<\/td>\n | Alphanumeric splash waterproof polyester soft keys.<\/td>\n<\/tr>\n | Titration Head<\/td>\n | Manual Stand with swivelling arm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n | <\/div>","protected":false},"excerpt":{"rendered":" The 12 series of Aut…<\/p>\n","protected":false},"author":18,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14320"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=14320"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/14320\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=14320"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=14320"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=14320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}} |