{"id":1578,"date":"2014-11-12T17:51:25","date_gmt":"2014-11-12T09:51:25","guid":{"rendered":"http:\/\/www.bihec.com\/?p=1578"},"modified":"2015-07-24T02:58:16","modified_gmt":"2015-07-23T18:58:16","slug":"%e5%be%b7%e5%9b%bdhoentzsch-%e8%99%b9%e9%a9%b0%e5%85%ac%e5%8f%b8-ultrasonic-ua-%e6%b5%81%e9%87%8f%e8%ae%a1","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/h-ntzsch-gmbh-hontzsch-hoentzsch\/%e5%be%b7%e5%9b%bdhoentzsch-%e8%99%b9%e9%a9%b0%e5%85%ac%e5%8f%b8-ultrasonic-ua-%e6%b5%81%e9%87%8f%e8%ae%a1\/","title":{"rendered":"Ultrasonic UA \u6d41\u91cf\u8ba1"},"content":{"rendered":"

\n\t <\/span>\n<\/p>\n

\n
\n

\n\t\t\tEXACTSONIC II – PORTABLE ULTRASONIC FLOW METER FOR LIQUIDS
\n\t\t<\/h2>\n

\n\t\t\tThis principle of measurement is also referred to as the transit time difference method. For measuring the flow rate of liquids using this technique, ultrasonic pulses are sent and received simultaneously through the medium in the direction of flow and against it. The sensors work alternately as transmitter and receiver. The transit time of the acoustic signals filtered through the medium in the direction of flow is shorter than that against it. The difference in transit time Δt is measured and can be used to calculate the average flow velocity of liquids filtering through the acoustic path. After measuring the flow velocity and with the pipe cross-sectional area, volumetric flow can be calculated.\n\t\t<\/p>\n

\n\t\t\tThese ultrasonic flowmeters have many benefits, for example, the measuring instruments produce accurate results in just a matter of minutes, they are easy to install and operate, there is no process interruption and there are no pipe restrictions. As a result, there is no pressure loss and therefore, time and cost savings as the ultrasonic flow meter is easy to install on the pipe.\n\t\t<\/p>\n

\n\t\t\tAdvantages of non-invasive measuring with the ultrasonic flowmeters:\n\t\t<\/p>\n

    \n
  • \n\t\t\t\tinstallation without process interruption or shut-down\n\t\t\t<\/li>\n
  • \n\t\t\t\teasy and cost-effective assembly\n\t\t\t<\/li>\n
  • \n\t\t\t\tlight-weight ergonomic design\n\t\t\t<\/li>\n
  • \n\t\t\t\tideal for use in maintenance areas and commissioning\n\t\t\t<\/li>\n
  • \n\t\t\t\ttesting fixed measuring equipment\n\t\t\t<\/li>\n<\/ul>\n

    \n\t\t\tDevice-related advantages of the ultrasonic flow measurement equipment compared to other products:\n\t\t<\/p>\n

      \n
    • \n\t\t\t\tno zero point alignment of the flow meter necessary\n\t\t\t<\/li>\n
    • \n\t\t\t\tcoverage of the most frequent industrial applications for flow measurement of liquids with just two transducer sets\n\t\t\t<\/li>\n
    • \n\t\t\t\thigh-capacity data logger with numerous parameters for pipe materials and mediums\n\t\t\t<\/li>\n
    • \n\t\t\t\tstable and reliable results even under difficult conditions\n\t\t\t<\/li>\n
    • \n\t\t\t\texcellent reproducibility of results\n\t\t\t<\/li>\n<\/ul>\n

      \n\t\t\tMeasurement-related advantages of the ultrasonic flow meter:\n\t\t<\/p>\n

        \n
      • \n\t\t\t\tnon-contact measurement\n\t\t\t<\/li>\n
      • \n\t\t\t\tindependent of pressure, temperature, conductivity and viscosity\n\t\t\t<\/li>\n
      • \n\t\t\t\tunlimited plant availability, as no process interruption\n\t\t\t<\/li>\n
      • \n\t\t\t\tno pressure losses when measuring flow rate, no risk of leakage, no cleaning necessary\n\t\t\t<\/li>\n
      • \n\t\t\t\tno mismeasurements as a result of blocked impulse pipes\n\t\t\t<\/li>\n
      • \n\t\t\t\tlogging of lowest flow velocities (min. 0.2 m\/s) resulting in high measuring dynamics\n\t\t\t<\/li>\n<\/ul>\n

        \n\t\t\tCost advantages of the ultrasonic flowmeters:\n\t\t<\/p>\n

          \n
        • \n\t\t\t\teasy retrofitting\n\t\t\t<\/li>\n
        • \n\t\t\t\tlow-cost installation and upkeep\n\t\t\t<\/li>\n
        • \n\t\t\t\tno maintenance effort or cleaning process necessary\n\t\t\t<\/li>\n<\/ul>\n

          \n\t\t\tresulting in an excellent cost-benefit ratio.\n\t\t<\/p>\n

          \n\t\t\tAPPLICATIONS \/ MEDIUMS \/ INDUSTRIES
          \n\t\t<\/h2>\n

          \n\t\t\tFlow rate measurement in liquid-filled pipes, HVAC systems, pump and technical system verification, boiler testing, leak detection, filter sizing, fire and hydraulic systems.\n\t\t<\/p>\n

          \n\t\t\tNon-contact measurement from the outside means that the ultrasonic flow measuring instrument is indispensable in many branches of industry, such as, water management, building services, energy sector, chemical and pharmaceutical, food technology and petrochemical.\n\t\t<\/p>\n

          \n\t\t\tChemical  <\/span>

          \n\t\t\tAggressive, toxic, high-viscosity and non-conductive fluids\n\t\t<\/p>\n

          \n\t\t\tPetrochemical<\/span>

          \n\t\t\tFlow measurement of various intermediate or end products, e.g. tar, bitumen\n\t\t<\/p>\n

          \n\t\t\tOffshore Industry<\/span>

          \n\t\t\tMeasuring liquid hydrocarbon\n\t\t<\/p>\n

          \n\t\t\tPower plants <\/span>

          \n\t\t\tOperational measuring of coolants and boiler feed water, condensate\n\t\t<\/p>\n

          \n\t\t\tPharmaceutical, Semiconductor Industry<\/span>

          \n\t\t\tUltrapure liquids \/ fluids\n\t\t<\/p>\n

          \n\t\t\tBeverage industry<\/span>

          \n\t\t\tHygienic measuring in bottling plants or tank installations\n\t\t<\/p>\n

          \n\t\t\tWater \/ sewage<\/span>

          \n\t\t\tMeasuring in large pipes and underground pipes and ducts\n\t\t<\/p>\n

          \n\t\t\tPlant engineering and construction<\/span>

          \n\t\t\tAny flow rate measurement, e.g. leakage detection in hydraulic plants, pump verification\n\t\t<\/p>\n

          \n\t\t\tAerospace<\/span>

          \n\t\t\tTesting hydraulic, supply and cooling systems\n\t\t<\/p>\n

          \n\t\t\tThese are just some examples of typical mediums in various branches of industry.\n\t\t<\/p>\n

          \n\t\t\tOther mediums suited for this principle of measurement:

          \n\t\t\tde-mineralized water, drinking water, river water, water-glycol mixtures, hydraulic oil, diesel, fuel oil, petroleum products, etc.\n\t\t<\/p>\n

          \n\t\t\tTechnical Data<\/span>\n\t\t<\/p>\n

            \n
          • \n\t\t\t\tflow velocity range 0.2 … 20 m\/s\n\t\t\t<\/li>\n
          • \n\t\t\t\tbi-directional\n\t\t\t<\/li>\n
          • \n\t\t\t\tmeasurement uncertainty: pipe OD > 75 mm: ± 2 % of measured value\n\t\t\t<\/li>\n
          • \n\t\t\t\tmenu-oriented operation\n\t\t\t<\/li>\n
          • \n\t\t\t\tbacklit graphic display, 64 x 240 pixels\n\t\t\t<\/li>\n
          • \n\t\t\t\tprogramming via 16 key control panel\n\t\t\t<\/li>\n
          • \n\t\t\t\tbattery or mains operation\n\t\t\t<\/li>\n
          • \n\t\t\t\tbattery life up to 20 hours\n\t\t\t<\/li>\n
          • \n\t\t\t\tpower 110 … 240 VAC +\/-10 %\n\t\t\t<\/li>\n
          • \n\t\t\t\t10 user selectable languages: German, English, French, Italian, Dutch, Swedish, Norwegian, Portuguese, Russian, Spanish\n\t\t\t<\/li>\n
          • \n\t\t\t\tincl. two transducer sets 'A' & 'B': pair 'A' for pipe OD 13 … 115 mm

            \n\t\t\t\tpair 'B' for pipe OD 50 … 2000 mm\n\t\t\t<\/li>\n
          • \n\t\t\t\ttransducer working temperature range: -20 … +135 °C\n\t\t\t<\/li>\n
          • \n\t\t\t\toutputs 0\/4-20 mA, RS232\/USB, opto-isolated, pulse output 5 V, max. 1 pulse\/s\n\t\t\t<\/li>\n
          • \n\t\t\t\tdata logger: 98000 data points, 20 named record blocks, display in text or graph format, download via RS232\/USB to Windows PC\n\t\t\t<\/li>\n
          • \n\t\t\t\tdelivered with robust IP67 carrying case\n\t\t\t<\/li>\n<\/ul>\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n\n
            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\t \n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tVANE WHEEL FLOW SENSOR FA DI<\/a><\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tVORTEX FLOW SENSOR VA DI<\/a><\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tTHERMAL FLOW SENSOR TA DI<\/a><\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tULTRASONIC FLOW METER EXACTSONIC II<\/a><\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tGaseous mediums<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tair \/ gases<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tair \/ gases<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tair \/ gases<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tLiquid mediums<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tliquids with viscosity < 200 cSt<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tall liquid mediums<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tPrincipal areas of application<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tmeasuring in clean gases and liquids, control measuring in gases and liquids<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tmeasuring in particle and condensate laden gases<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tair mass flow measurement, measurement of compressed air<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tportable flow rate measuring in liquid-filled pipes<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tMeasured variables<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tactual flow rate<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tactual flow rate<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tstandard flow rate<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tflow velocity \/ flow rate<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tMeasuring ranges (in stages)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0.2 … 120 m\/s<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0.4 … 40 m\/s<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0.08 … 200 Nm\/s<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0,1 … 20 m\/s<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tFlow rate measuring ranges (in stages)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tup to 1132 m³\/h<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0.7 … 4523 m³\/h<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t0.04 … 988 Nm³\/h<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tWorking pressure (overpressure)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t1 MPa \/10 bar<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t1 MPa \/ 10 bar<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t2.5 MPa \/25 bar<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tnot relevant<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tWorking temperature range<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t-40 … +550 °C<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t-10 … +180 °C<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t-10 … +240 °C<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t-20 … +135 °C<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tTemperature measuring range (with integrated Pt100)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t-10 … +240 °C<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tnot relevant<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tEx-protection zone 0 \/ category 1 (gases)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/error.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tEx-protection zone 1 \/ category 2 (gases)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/error.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tEx-protection zone 20 \/ category 1D (dust)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/error.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tEx-protection zone 21 \/ category 2D (dust)<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/check.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t\"http:\/\/www.hoentzsch.com\/fileadmin\/templates\/hoentzsch_website\/imgs\/error.png\"<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tMaterials in contact with mediums<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tstainless steel, aluminium, PVDF …<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tstainless steel …<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tstainless steel …<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tMeasuring tube inside diameters<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t9.7 … 100 mm<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t25 … 200 mm<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t8 … 41.8 mm<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tfrom 13 mm<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n

            \n

            \n\t\t\t\t\t\t\tSensor with directional sensing<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tFAR<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tVAR<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\t–<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n

            \n

            \n\t\t\t\t\t\t\tUA<\/strong>\n\t\t\t\t\t\t<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n

            \n\t\t\tAll Model:\n\t\t<\/p>\n

            \n\t\t\tVane Wheel FA<\/span>

            \n\t\t\tZS25<\/span>

            \n\t\t\tZG4<\/span>

            \n\t\t\t250GE<\/span>

            \n\t\t\t350GE<\/span>

            \n\t\t\t450GE<\/span>

            \n\t\t\t550GE<\/span>

            \n\t\t\t650GE<\/span>

            \n\t\t\tZG1<\/span>

            \n\t\t\tZG2<\/span>

            \n\t\t\tZG1\/ZG2<\/span>

            \n\t\t\tZG3<\/span>

            \n\t\t\tZS25\/27<\/span>

            \n\t\t\tZS25<\/span>

            \n\t\t\tZS27<\/span>

            \n\t\t\tZG5<\/span>

            \n\t\t\tZG4<\/span>

            \n\t\t\tZS30<\/span>

            \n\t\t\tZS16<\/span>

            \n\t\t\tZSR25<\/span>

            \n\t\t\tFT25<\/span>

            \n\t\t\tTS\/TSR<\/span>

            \n\t\t\tFA·Di 9.7GE<\/span>

            \n\t\t\tµP-ASD-R<\/span>

            \n\t\t\tµP-ASD<\/span>

            \n\t\t\tVortex VA<\/span>

            \n\t\t\tVA40<\/span>

            \n\t\t\tZG7<\/span>

            \n\t\t\tZG8<\/span>

            \n\t\t\tVA42<\/span>

            \n\t\t\tFLOWTHERM<\/span>

            \n\t\t\tThermal TA<\/span>

            \n\t\t\tUltrasonic UA<\/span>

            \n\t\t\tVortex VA<\/span>

            \n\t\t\tThermal TA<\/span>

            \n\t\t\tUltrasonic UA<\/span>\n\t\t<\/p>\n<\/p><\/div>\n<\/div>\n

            \u53f6\u8f6e\u6d41\u91cf\u8ba1<\/a>\n\u6d41\u91cf\u8ba1<\/a>\n\u6da1\u8857\u6d41\u91cf\u8ba1<\/a>\n\u70ed\u5f0f\u6d41\u91cf\u8ba1<\/a><\/div>","protected":false},"excerpt":{"rendered":"

              EXACTSONIC II…<\/p>\n","protected":false},"author":8,"featured_media":1579,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[597,1978],"tags":[99,193,100,101],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/1578"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=1578"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/1578\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media\/1579"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=1578"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=1578"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=1578"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}