\u6d41\u91cf\u8ba1<\/a>\u3001\u6d41\u91cf\u53d8\u9001\u5668\u3001\u6d41\u91cf\u5f00\u5173\u4e13\u4e1a\u751f\u4ea7\u5382\u5bb6\uff0c\u63d0\u4f9b\u5b8c\u5584\u7684\u51b7\u51bb\u6c34\u3001\u7a7a\u6c14\u3001\u6c2e\u6c14\u3001\u84b8\u6c7d\u3001\u6da6\u6ed1\u6cb9\u6216\u5176\u4ed6\u5de5\u827a\u6db2\u4f53\u6d41\u91cf\u6d4b\u91cf\u89e3\u51b3\u65b9\u6848\u3002<\/p>\n <\/p>\n
3500 Armor-Flo meter with Limit Switch<\/p>\n
<\/p>\n
<\/p>\n
In addition to the performance benefits of the 3400 Series flow rate meter, the 3500 Series Armor-Flotm includes switching capabilities. Adjustable flow switches provide positive indication of flow\/no flow conditions or may be positioned to establish process limits. In either application the switch captures the indicator preventing movement until the flow rate is within the acceptable range.<\/p>\n
<\/p>\n
The glass encapsulated reed switches are SPDT rated at 0.25 amperes at 120vac (1.5 amperes at 24vdc). This switch is appropriate for use in Class I, Division 2 areas.<\/p>\n
<\/p>\n
<\/p>\n
Quick Overview<\/p>\n
Description: Flow rate meter with lo\/hi limit switches<\/p>\n
Applications: Liquids, gases or steam<\/p>\n
Functions: Direct reading flow rate, Lo\/Hi switches<\/p>\n
Features: Meter w\/ adjustable switches,Opaque fluids OK,Calibrated for application conditions<\/p>\n
Materials: Aluminum, brass, 316 sst, or (Haste alloy 1\/2-1″)<\/p>\n
Pressure Limits: 200 psig 1\/2 – 12″, 400 psig 1\/2 – 6″, 1000 psig 1\/2 – 1″<\/p>\n
Temperature Limits: 400\u00baF rating requires epm or viton o-ring<\/p>\n
Pipe Sizes: 1\/2″-12″<\/p>\n
<\/div>","protected":false},"excerpt":{"rendered":"
\u7f8e\u56fdERDCO\u516c\u53f8\u662f\u4e16\u754c\u8457\u540d\u7684\u6d41\u91cf\u8ba1\u3001\u6d41…<\/p>\n","protected":false},"author":8,"featured_media":3342,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[499],"tags":[],"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/3341"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=3341"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/3341\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media\/3342"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=3341"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=3341"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=3341"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}