{"id":6913,"date":"2015-10-21T15:17:27","date_gmt":"2015-10-21T07:17:27","guid":{"rendered":"http:\/\/www.bihec.com\/?p=6913"},"modified":"2017-03-17T20:29:37","modified_gmt":"2017-03-17T12:29:37","slug":"fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/","title":{"rendered":"FA 300-2 Ex – Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668"},"content":{"rendered":"

\u57281\u533a\u7206\u70b8\u533a\u57df\u7684\u538b\u529b\u9732\u70b9\uff0c\u9632\u62a4\u7b49\u7ea7\uff1aFA300-2Ex: I 2G Ex ia II C T4\u3002<\/p>\n

ATEX\u8ba4\u8bc1\uff0c\u7528\u4e8e1\u533a\u7684\u5efa\u7acb\u9732\u70b9\u6d4b\u91cf\u4eea\u5668FA300-2\u73b0\u5728\u4e5f\u53ef\u4ee5\u7528\u5728\u5de5\u4e1a\u70b8\u836f\u9886\u57df\u3002<\/p>\n

FA300-2 Ex\u53ea\u80fd\u53ef\u4ee5\u548c\u8ba4\u8bc1\u7684Ex-rated\u6216\u5b89\u5168\u6805\u6216\u6700\u5927\u7535\u5316\u5206\u79bb\u5143\u4ef6\u4e00\u8d77\u4f7f\u7528\uff1a<\/p>\n

U0=30 V\u6700\u5927\u3002<\/p>\n

I0=100 mA \u6700\u5927\u3002<\/p>\n

P0=1 W\uff08\u6700\u5927\u503c\uff09<\/p>\n

FA300-2 Ex\u7684\u7279\u6b8a\u529f\u80fd<\/p>\n

\u575a\u56fa\u7684\u8bbe\u8ba1
\n\u8010\u538b\u9ad8\u8fbe300bar
\n\u957f\u671f\u7a33\u5b9a\u7684\u6e7f\u5ea6<\/a>\u4f20\u611f\u5668\uff0c\u901a\u8fc7\u8ba4\u8bc1
\n2\u7ebf\u7cfb\u7edf\u76844…20 mA\u7684\u6a21\u62df\u8f93\u51fa
\n\u901a\u8fc7\u8f6f\u4ef6\u8c03\u8282\u8fdb\u4e00\u6b65\u7684\u53c2\u6570\uff1a\uff05RH\u6e7f\u5ea6\u767e\u5206\u6bd4\uff0cg\/m\u00b3\u514b\/\u7acb\u65b9\u7c73\uff0cmg\/m\u00b3\u6beb\u514b\/\u7acb\u65b9\u7c73\uff0cPPM\uff0cV\/ V\uff0cg\/kg\u514b\/\u516c\u65a4\uff1a
\nCS\u670d\u52a1\u8f6f\u4ef6\u8fdb\u884c\u6570\u636e\u5b58\u50a8\u548c\u6821\u51c6\uff08\u65e0\u6279\u51c6\u6613\u7206\u533a\u57df\uff09<\/p>\n

<\/div>","protected":false},"excerpt":{"rendered":"

\u57281\u533a\u7206\u70b8\u533a\u57df\u7684\u538b\u529b\u9732\u70b9\uff0c\u9632\u62a4\u7b49\u7ea7\uff1aFA…<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[581],"tags":[],"yoast_head":"\nFA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1\u9732\u70b9\u4f20\u611f\u5668-2\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1\" \/>\n<meta property=\"og:description\" content=\"\u57281\u533a\u7206\u70b8\u533a\u57df\u7684\u538b\u529b\u9732\u70b9\uff0c\u9632\u62a4\u7b49\u7ea7\uff1aFA…\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1\u9732\u70b9\u4f20\u611f\u5668-2\/\" \/>\n<meta property=\"og:site_name\" content=\"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1\" \/>\n<meta property=\"article:published_time\" content=\"2015-10-21T07:17:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-03-17T12:29:37+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u4f5c\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.bihec.com\/#website\",\"url\":\"https:\/\/www.bihec.com\/\",\"name\":\"\\u7695\\u8d6b\\u56fd\\u9645-\\u5728\\u7ebf\\u7c98\\u5ea6\\u8ba1-\\u4fbf\\u643a\\u5f0f\\u7c98\\u5ea6\\u8ba1\",\"description\":\"\\u6bdb\\u7ec6\\u7ba1\\u7c98\\u5ea6\\u8ba1 \\u5728\\u7ebf\\u5bc6\\u5ea6\\u8ba1 \\u4fbf\\u643a\\u5f0f\\u5bc6\\u5ea6\\u8ba1 \\u7c89\\u4f53\\u6d41\\u53d8\\u4eea CD\\u5706\\u4e8c\\u8272\\u5149\\u8c31\\u4eea CPL\\u5706\\u504f\\u632f\\u8367\\u5149\\u5149\\u8c31\\u4eea \\u611f\\u5e94\\u52a0\\u70ed\\u5668 \\u7535\\u5b50\\u67aa \\u8868\\u9762\\u5f20\\u529b\\u4eea UIC\\u78b3\\u786b\\u5206\\u6790\\u4eea \\u5bfc\\u70ed\\u7cfb\\u6570\\u4eea \\u6fc0\\u5149\\u51c6\\u76f4\\u4eea\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.bihec.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"zh-CN\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#webpage\",\"url\":\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/\",\"name\":\"FA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\\u9732\\u70b9\\u4f20\\u611f\\u5668 - \\u7695\\u8d6b\\u56fd\\u9645-\\u5728\\u7ebf\\u7c98\\u5ea6\\u8ba1-\\u4fbf\\u643a\\u5f0f\\u7c98\\u5ea6\\u8ba1\",\"isPartOf\":{\"@id\":\"https:\/\/www.bihec.com\/#website\"},\"datePublished\":\"2015-10-21T07:17:27+00:00\",\"dateModified\":\"2017-03-17T12:29:37+00:00\",\"author\":{\"@id\":\"https:\/\/www.bihec.com\/#\/schema\/person\/bfbb872864afde3606e17dc7d781dfa1\"},\"breadcrumb\":{\"@id\":\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#breadcrumb\"},\"inLanguage\":\"zh-CN\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\\u9996\\u9875\",\"item\":\"https:\/\/www.bihec.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FA 300-2 Ex – Dew point sensor with ATEX approval for Zone 1\\u9732\\u70b9\\u4f20\\u611f\\u5668\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.bihec.com\/#\/schema\/person\/bfbb872864afde3606e17dc7d781dfa1\",\"name\":\"\\u5ba2\\u670d\\u70ed\\u7ebf\\uff1a400-840-1510\",\"description\":\"\\u7535\\u8bdd\\uff1a400-840-1510\\u8f6c1002 \\u624b\\u673a\\uff1a177-1730-1702 \\u4f20\\u771f\\uff1a021-51062822 Email\\uff1aliuyq@bihec.com\",\"url\":\"https:\/\/www.bihec.com\/author\/liuyqbihec-com\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1\u9732\u70b9\u4f20\u611f\u5668-2\/","og_locale":"zh_CN","og_type":"article","og_title":"FA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","og_description":"\u57281\u533a\u7206\u70b8\u533a\u57df\u7684\u538b\u529b\u9732\u70b9\uff0c\u9632\u62a4\u7b49\u7ea7\uff1aFA…","og_url":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1\u9732\u70b9\u4f20\u611f\u5668-2\/","og_site_name":"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","article_published_time":"2015-10-21T07:17:27+00:00","article_modified_time":"2017-03-17T12:29:37+00:00","twitter_card":"summary_large_image","twitter_misc":{"\u4f5c\u8005":"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.bihec.com\/#website","url":"https:\/\/www.bihec.com\/","name":"\u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","description":"\u6bdb\u7ec6\u7ba1\u7c98\u5ea6\u8ba1 \u5728\u7ebf\u5bc6\u5ea6\u8ba1 \u4fbf\u643a\u5f0f\u5bc6\u5ea6\u8ba1 \u7c89\u4f53\u6d41\u53d8\u4eea CD\u5706\u4e8c\u8272\u5149\u8c31\u4eea CPL\u5706\u504f\u632f\u8367\u5149\u5149\u8c31\u4eea \u611f\u5e94\u52a0\u70ed\u5668 \u7535\u5b50\u67aa \u8868\u9762\u5f20\u529b\u4eea UIC\u78b3\u786b\u5206\u6790\u4eea \u5bfc\u70ed\u7cfb\u6570\u4eea \u6fc0\u5149\u51c6\u76f4\u4eea","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bihec.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"zh-CN"},{"@type":"WebPage","@id":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#webpage","url":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/","name":"FA 300-2 Ex - Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668 - \u7695\u8d6b\u56fd\u9645-\u5728\u7ebf\u7c98\u5ea6\u8ba1-\u4fbf\u643a\u5f0f\u7c98\u5ea6\u8ba1","isPartOf":{"@id":"https:\/\/www.bihec.com\/#website"},"datePublished":"2015-10-21T07:17:27+00:00","dateModified":"2017-03-17T12:29:37+00:00","author":{"@id":"https:\/\/www.bihec.com\/#\/schema\/person\/bfbb872864afde3606e17dc7d781dfa1"},"breadcrumb":{"@id":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#breadcrumb"},"inLanguage":"zh-CN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.bihec.com\/cs-instruments-gmbh\/fa-300-2-ex-dew-point-sensor-with-atex-approval-for-zone-1%e9%9c%b2%e7%82%b9%e4%bc%a0%e6%84%9f%e5%99%a8-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/www.bihec.com\/"},{"@type":"ListItem","position":2,"name":"FA 300-2 Ex – Dew point sensor with ATEX approval for Zone 1\u9732\u70b9\u4f20\u611f\u5668"}]},{"@type":"Person","@id":"https:\/\/www.bihec.com\/#\/schema\/person\/bfbb872864afde3606e17dc7d781dfa1","name":"\u5ba2\u670d\u70ed\u7ebf\uff1a400-840-1510","description":"\u7535\u8bdd\uff1a400-840-1510\u8f6c1002 \u624b\u673a\uff1a177-1730-1702 \u4f20\u771f\uff1a021-51062822 Email\uff1aliuyq@bihec.com","url":"https:\/\/www.bihec.com\/author\/liuyqbihec-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/6913"}],"collection":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/comments?post=6913"}],"version-history":[{"count":0,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/posts\/6913\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/media?parent=6913"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/categories?post=6913"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bihec.com\/wp-json\/wp\/v2\/tags?post=6913"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}