Additel 780<\/strong><\/p>\nAdditel 780\u662f\u4e00\u6b3e\u53f0\u5f0f\u63a7\u5236\u5668\uff0c\u4e13\u4e3a\u529f\u80fd\u6027\u548c\u6613\u7528\u6027\u800c\u8bbe\u8ba1\u3002\u8be5\u63a7\u5236\u5668\u7684\u91cf\u7a0b\u9ad8\u8fbe1000\u78c5\/\u5e73\u65b9\u82f1\u5bf8\uff0c\u6216\u5e26\u6c14\u74f6\u76843000\u78c5\/\u5e73\u65b9\u7c73\uff0c\u6807\u51c6\u7cbe\u5ea6\u4e3a0.02%\uff08\u53ef\u80fd\u6709\u66f4\u597d\u7684\u7cbe\u5ea6\uff09\uff0c\u9002\u7528\u4e8e\u8bb8\u591a\u538b\u529b\u5e94\u7528\u3002\u6b64\u5916\uff0c780\u8fd8\u5305\u62ecHART\u00ae\u548cProfibus PA\u901a\u4fe1\uff0c\u4ee5\u5141\u8bb8\u4e0e\u5176\u4ed6\u5de5\u827a\u8bbe\u5907\u8fdb\u884c\u4ea4\u4e92\u3002<\/p>\n
Additel 780S<\/strong><\/p>\n\u8981\u83b7\u5f97\u6bd4Additel 780\u66f4\u7b80\u5355\u7684\u89e3\u51b3\u65b9\u6848\uff0c\u8bf7\u8003\u8651\u7ecf\u6d4e\u4e14\u7528\u6237\u53cb\u597d\u7684Additel 780S\u3002\uff08\u5305\u542b\u4e0e780\u672c\u8eab\u7c7b\u4f3c\u7684\u529f\u80fd\uff0cHART\u548cProfibus\u901a\u4fe1\u9664\u5916\uff09<\/p>\n
\n
\n
\n\n\nSpecification<\/strong><\/th>\nADT780-1K<\/strong><\/th>\nADT780-3K<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nPressure range<\/strong><\/td>\n-14.5 to 1,000 psi (-0.95 to 70 bar)<\/td>\n | -14.5 to 3,000 psi (-0.95 to 200 bar)[1]<\/td>\n<\/tr>\n | \nControl stability<\/strong><\/td>\n0.003% FS (stability based on % FS of control sensor range)<\/td>\n<\/tr>\n | \nPrecision (includes 1 year stability)<\/strong><\/td>\nSee pressure range table<\/td>\n<\/tr>\n | \nMedia<\/strong><\/td>\nClean gas<\/td>\n<\/tr>\n | \nOver-range indication<\/strong><\/td>\n103% to 120% (based on sensor)<\/td>\n<\/tr>\n | \nResolution<\/strong><\/td>\n4, 5, 6, or 7 digits (user selectable)[2]<\/td>\n<\/tr>\n | \nPressure type<\/strong><\/td>\nGauge, Absolute<\/td>\n<\/tr>\n | \nWarm up time<\/strong><\/td>\n15 minutes<\/td>\n<\/tr>\n | \nMeasurement units<\/strong><\/td>\nPa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0\u00b0C,cmHg@0\u00b0C, mHg@0\u00b0C, inHg@0\u00b0C, inH2O@4\u00b0C, mmH2O@4\u00b0C, cmH2O@4\u00b0C, mH2O@4\u00b0C, mmH2O@20\u00b0C, cmH2O@20\u00b0C, mH2O@20\u00b0C, kg\/m2, kg\/cm2, mtorr, torr, atm, lb\/ft2, tsi, user selectable<\/td>\n<\/tr>\n | \nMinimum control pressure[3]<\/strong><\/td>\n0.0001 psi<\/td>\n | 0.001 psi<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n <\/p>\n<\/div>\n \n \n \n\n\nBAROMETRIC MEASUREMENT SPECIFICATION<\/strong><\/th>\n<\/tr>\n\nBarometer<\/strong><\/th>\nAccuracy<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nStandard<\/strong><\/td>\n55n Pa<\/td>\n<\/tr>\n | \nHigh Accuracy (HABP)<\/strong><\/td>\n10 Pa<\/td>\n<\/tr>\n | \nBarometer range (60~110) kPa, the accuracy includes calibration uncertainty, linearity, and long term stability<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n <\/p>\n<\/div>\n \n \n \n\n\nELECTRICAL MEASURE SPECIFICATIONS<\/strong><\/th>\n<\/tr>\n\nSpecification<\/strong><\/th>\nRange<\/strong><\/th>\nResolution<\/strong><\/th>\nAccuracy<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nVolts DC<\/strong><\/td>\n-30 to 30 V<\/td>\n | 0.1 mV<\/td>\n | \u00b10.01% rdg + 1.5 mV<\/td>\n<\/tr>\n | \n-300 to 300 mV<\/td>\n | 1 \u03bcV<\/td>\n | \u00b10.01% rdg + 15 \u03bcV<\/td>\n<\/tr>\n | \nCurrent DC<\/strong><\/td>\n-30 to 30 mA<\/td>\n | 0.1 \u03bcA<\/td>\n | \u00b10.01% rdg + 1.5 \u03bcA<\/td>\n<\/tr>\n | \nSwitch test<\/strong><\/td>\nIf the switch has detected voltage, the range is from 3 \u2013 24 V<\/td>\n<\/tr>\n | \nDC 24V output<\/strong><\/td>\n24V \u00b1 0.24V, max 30 mA<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n <\/p>\n \n \n\n\nPHYSICAL SPECIFICATIONS<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nSpecification<\/strong><\/td>\nADT780-1K & ADT780-3K<\/td>\n<\/tr>\n | \nPower<\/strong><\/td>\n100 to 240V, 50\/60 Hz<\/td>\n<\/tr>\n | \nPressure ports<\/strong><\/td>\nG1\/8 F<\/td>\n<\/tr>\n | \nStorage temperature<\/strong><\/td>\n-20\u00b0C to 70\u00b0C<\/td>\n<\/tr>\n | \nOperating environment<\/strong><\/td>\n0-90% RH non-condensing<\/td>\n<\/tr>\n | \nDisplay<\/strong><\/td>\n7 inch (17.8 cm) color, touch screen display<\/td>\n<\/tr>\n | \nWeight<\/strong><\/td>\n33 lbs (15 kg)<\/td>\n<\/tr>\n | \nDimensions (DWH)<\/strong><\/td>\n16.5 x 17.3 x 5.2 inch (419 x 440 x 132 mm)<\/td>\n<\/tr>\n | \nMounting<\/strong><\/td>\nStandard desktop, optional rack mount kit<\/td>\n<\/tr>\n | \nShock<\/strong><\/td>\n4G<\/td>\n<\/tr>\n | \nVibration<\/strong><\/td>\n1G 10Hz~500Hz<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n <\/p>\n \n \n \n\n\nOTHER SPECIFICATIONS<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nWiFi specifications<\/strong><\/td>\n802.11 b, g, and n<\/td>\n<\/tr>\n | \nVent<\/strong><\/td>\nFront panel vent and safety release button (only for 780S)<\/td>\n<\/tr>\n | \nCommunications<\/strong><\/td>\nRS232,USB,LAN,WIFI<\/td>\n<\/tr>\n | \nStability indicator<\/strong><\/td>\nUser selectable<\/td>\n<\/tr>\n | \nOperating modes<\/strong><\/td>\nControl, measure, and vent<\/td>\n<\/tr>\n | \nDisplay modes<\/strong><\/td>\nController \u2013 show pressure indication and control<\/td>\n<\/tr>\n | \nLocalization<\/strong><\/td>\nEnglish, Chinese (simplified), German, Spanish, French, Italian, Portuguese, Russian, Japanese<\/td>\n<\/tr>\n | \nConformity<\/strong><\/td>\nCE<\/td>\n<\/tr>\n | \nCalibration certification<\/strong><\/td>\nAccredited certificate of calibration with data included<\/td>\n<\/tr>\n | \nWarranty<\/strong><\/td>\n1 year<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n <\/p>\n<\/div>\n \n \n \n\n\nSpecifications for ADT780 Internal \/ External Sensors (Standard Pressure Sensors)<\/strong><\/th>\n<\/tr>\n\nP\/N<\/strong><\/th>\nPressure Range<\/strong><\/th>\nMedia<\/strong><\/th>\nAccuracy<\/strong><\/th>\nPressure Rating<\/strong><\/th>\nSuggested Controller Compatibility<\/strong><\/th>\nInternal\/ External Use<\/strong><\/th>\n<\/tr>\n\npsig<\/strong><\/th>\nbar.g<\/strong><\/th>\nBurst<\/strong><\/th>\nOver Pressure<\/strong><\/th>\n<\/tr>\n\nStandard Pressure Sensors<\/strong><\/th>\n<\/tr>\n<\/thead>\n\n\nCP10<\/strong><\/td>\n\u00b110<\/td>\n | \u00b10.7<\/td>\n | G<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | ADT780-1K only<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP15<\/strong><\/td>\n\u00b115<\/td>\n | \u00b11.0<\/td>\n | G<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | ADT780-1K only<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP30<\/strong><\/td>\n-15 to 30<\/td>\n | -1 to 2.0<\/td>\n | G<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | ADT780-1K only<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP50<\/strong><\/td>\n-15 to 50<\/td>\n | -1 to 3.5<\/td>\n | G<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | ADT780-1K only<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP100<\/strong><\/td>\n-15 to 100<\/td>\n | -1 to 7.0<\/td>\n | G,L<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | ADT780-1K only<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP300<\/strong><\/td>\n-15 to 300<\/td>\n | -1 to 20<\/td>\n | G,L<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | Both<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP500<\/strong><\/td>\n-15 to 500<\/td>\n | -1 to 35<\/td>\n | G,L<\/td>\n | 0.02% FS<\/td>\n | 3x<\/td>\n | 1.2x<\/td>\n | Both<\/td>\n | Both<\/td>\n<\/tr>\n | \nCP600<\/strong><\/td>\n | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |