{"id":138,"date":"2023-11-21T13:42:38","date_gmt":"2023-11-21T05:42:38","guid":{"rendered":"https:\/\/www.bihec.com\/bms-bulut-makina\/?p=138"},"modified":"2023-11-21T13:42:38","modified_gmt":"2023-11-21T05:42:38","slug":"bms-bulut-makina-hardness-testers-%e7%a1%ac%e5%ba%a6%e6%b5%8b%e8%af%95%e4%bb%aa-%e6%a8%a1%e6%8b%9f%e6%b4%9b%e6%b0%8f%e7%a1%ac%e5%ba%a6%e6%b5%8b%e8%af%95%e4%bb%aa-%e6%a8%a1%e6%8b%9f%e6%b4%9b%e6%b0%8f","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/bms-bulut-makina\/bms-bulut-makina-hardness-testers-%e7%a1%ac%e5%ba%a6%e6%b5%8b%e8%af%95%e4%bb%aa-%e6%a8%a1%e6%8b%9f%e6%b4%9b%e6%b0%8f%e7%a1%ac%e5%ba%a6%e6%b5%8b%e8%af%95%e4%bb%aa-%e6%a8%a1%e6%8b%9f%e6%b4%9b%e6%b0%8f\/","title":{"rendered":"BMS Bulut makina-hardness testers \u786c\u5ea6\u6d4b\u8bd5\u4eea \u6a21\u62df\u6d1b\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea \u6a21\u62df\u6d1b\u6c0f\u548c\u5e03\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea \u6a21\u62df\u5f0f\u6d1b\u6c0f \u5e03\u6c0f\u548c\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea \u5fae\u578b\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea \u5e03\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea"},"content":{"rendered":"
BMS 150-C\u6a21\u62df\u6d1b\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/a><\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022 Pre \u2013load (kgf):10 DIGIROCK-RSR-M \u6570\u5b57\u5f0f\u7535\u52a8\u6d1b\u6c0f\u53ca\u6d1b\u6c0f\u5fae\u786c\u5ea6\u8ba1<\/strong><\/p>\n \u6280\u672f\u53c2\u6570<\/strong><\/p>\n \u2022 Pre-load (kgf):3 \/ 10 BMS 200-RB\u6a21\u62df\u6d1b\u6c0f\u548c\u5e03\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/a><\/strong><\/p>\n \u6280\u672f\u53c2\u6570<\/strong><\/p>\n \u2022 Pre-load (kgf):10 BMS 200-RBOV\u6a21\u62df\u5f0f\u6d1b\u6c0f<\/a>\u3001\u5e03\u6c0f\u548c\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/strong><\/p>\n \u6280\u672f\u53c2\u6570<\/strong><\/p>\n \u2022 Pre-load (kgf):10 DIGIROCK-LC-RBOV\u6570\u5b57\u5f0f\u7535\u52a8\u6d1b\u6c0f\u53ca\u6d1b\u6c0f\u5fae\u786c\u5ea6\u3001\u5e03\u6c0f\u548c\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/strong><\/p>\n \u5177\u6709\u95ed\u73af\u6280\u672f\u548c\u5149\u5b66\u7cfb\u7edf<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022 Pre-load ( kgf ):3 \/ 10 MICROBUL-N\u4f4e\u8d1f\u8377\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022 Test loads:(kgf)0,5;1;3;5(10kgf on request) MICROBUL 1000-DN<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n Vickers Test methods:HV0.01,HV0.025,HV0.05, HV 0.1, MICROBUL 1000-DN-AT\u6570\u5b57\u81ea\u52a8\u8f6c\u5854\u663e\u5fae\u7ef4\u6c0f\u786c\u5ea6\u8ba1\u914d\u6709PC\u7cfb\u7edf<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022Test force: 10gf, 25gf, 50gf, 100gf, 200gf, 300gf, 500gf, BMS 3000 OBPC-M – \u95ed\u73af\u3001\u89e6\u6478\u5c4f\u4e0e\u7535\u52a8\u5347\u964d\u87ba\u6746<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022 Test Loads (kgf):62,5-3000 XACT\u5e03\u6c0f\u3001\u7ef4\u6c0f\u3001\u5e93\u6c0f\u786c\u5ea6\u6d4b\u91cf<\/strong><\/p>\n \u4ea7\u54c1\u53c2\u6570<\/strong><\/p>\n \u2022 XACT Software \u6a21\u62df\u6d1b\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea BMS 150-C\u6a21\u62df\u6d1b\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea \u4ea7\u54c1\u53c2\u6570 \u2022 Pre \u2013load (kgf):10 \u2022 Test Loads:60, 100, 150 \u2022 Load se <\/p>\n","protected":false},"author":30,"featured_media":159,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[3],"tags":[4,9,11,10,8,7,6,5],"yoast_head":"\n<\/p>\n
\n\u2022 Test Loads:60, 100, 150
\n\u2022 Load selection:By load selector disc
\n\u2022 Test method:Rockwell
\n\u2022 Load Application:Hydraulic
\n\u2022 Max.test height(mm):(B)210
\n\u2022 Depth of throat(mm):(A)165
\n\u2022 Machine dimensions (mm):220x710x520
\n\u2022 Case dimensiond (mm):470x600x830
\n\u2022 Weight (net\/gross):kg73 \/ 90<\/p>\n<\/p>\n
\n\u2022 Test loads (kgf):15,30,45,60,100,150
\n\u2022 Load selection:by load selector disc
\n\u2022 Test method:Rockwell,Rockwell Superficial
\n\u2022 Digital display: 3.5 \u201c Color Touchscreen
\n\u2022 Load application:Motorised
\n\u2022 Max.test height:280 mm
\n\u2022 Depth of throat:145 mm
\n\u2022 Machine dim’s:720x520x280 mm
\n\u2022 Case dim’s:440x590x950 mm
\n\u2022 Weight (net\/gross):82\/110 kg<\/p>\n\u6a21\u62df\u6d1b\u6c0f\u548c\u5e03\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/a><\/strong><\/h2>\n
<\/p>\n
\n\u2022 Test loads (kgf):100,150 ; 62.5 ,60,187.5
\n\u2022 Load selection:by load selector disc
\n\u2022 Test method:Rockwell,Brinell
\n\u2022 Load application:Hydraulic
\n\u2022 Max.test height:280 mm
\n\u2022 Depth of throat:145 mm
\n\u2022 Machine dim’s:180x780x500 mm
\n\u2022 Case dim’s:440x590x950 mm
\n\u2022 Weight (net\/gross):90\/129 kg<\/p>\n\u6a21\u62df\u6d1b\u6c0f\u3001\u5e03\u6c0f\u548c\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/a><\/strong><\/h2>\n
<\/p>\n
\n\u2022Test Loads (kgf):60, 100, 150 (Rockwell),62.5, 187.5
\n(Brinell),30 (Vickers)
\n\u2022 Load Selection:By load selector disc
\n\u2022 Test Method:Rockwell, Brinell, Vickers
\n\u2022 Load Application:Hydraulic
\nMang.of measuring microscope:75xBrinell
\n,150xVickers
\n\u2022Max Test Height:With sliding table 140 mm,Without
\nsliding table 280 mm
\n\u2022 Depth of Throat:145 mm
\n\u2022 Machine Dimensions:180x780x500 mm
\n\u2022 Case Dimensions:440x590x950 mm
\n\u2022 Weight (net\/gross):100 \/ 134 kg
\n\u2022 Power Supply:220V, 50HZ<\/p>\n<\/p>\n
\n\u2022 Loads (kgf ):5;30;45 Superficial Rockwell
\n60;100;150 Rockwell
\n15,625;31;25;62.5;187.5;250 Brinell
\n3;5;10;20;30;100 Vickers
\n\u2022 Load selection:Automatic
\n\u2022Test methods:Rockwell, Rockwell Superficial, Brinell
\n& Vickers
\n\u2022 Digital display: 3.5 \u201c Color Touchscreen
\n\u2022 Load application:Automatic by stepping motor
\nMax. testing height:With sliding table 140 mm, without
\nsliding table 240 mm
\n\u2022 Throat:145 mm
\n\u2022 Machine dimensions:780X500X360 mm
\n\u2022 Case dimensions:950x700x350 mm
\n\u2022 Weight (net\/gross):95 \/ 125 kg
\nOptical system:75X magnification for Brinell 150X
\nmagnification for Vickers
\n\u2022 Power:220 V, 50Hz
\n\u2022 Language: Turkish, English, German, Russian, Italian,
\nSpanish, French, Arabic<\/p>\n\u5fae\u578b\u7ef4\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/a><\/strong><\/h2>\n
<\/p>\n
\n\u2022 Load selection:Manuel
\n\u2022 Test methods:Vickers & Brinell
\n\u2022 Digital display: 3.5 \u201c Color Touchscreen
\n\u2022 Load application:Automatic
\n\u2022 Hardness value:Automatic display manual measuring
\nTotal magnification of measuring microscope:360X
\n(with 25X objective)
\n\u2022 140X (with 10X objective)
\n\u2022 X-Y table dimensions (mm):100X100
\n\u2022 X-Y table travel (mm):25
\n\u2022 Max.testing height (mm):130
\n\u2022 Depth of thoroat (mm):130
\n\u2022 Power supply:AC 220V, 50Hz
\n\u2022 Machine dimensions (mm):190x750x480
\n\u2022 Case dimensions (mm):440x590x950
\n\u2022 Weight (nett \/gross) kg:68 \/ 100<\/p>\n<\/p>\n
\nHV 0.2, HV 0.3 ,HV 0.5,HV 1
\n\u2022 Test force unit:gf,mN
\nTest forces:(gf)10 25 50 100 200 300 500 1000 (mN)98
\n245 490 980 1960 2940 4900 9800
\n\u2022 Load Control:Automatic (loading \/ dwell \/ Unloading)
\n\u2022 Dwell time:5-99(1sec is increment)
\n\u2022 Test model:HV\/HK
\n\u2022 Hardness value:Automatic display manual measuring
\n\u2022 Optical system:10\u00d7,40\u00d7(test)
\n\u2022 Eyepiece:10\u00d7
\n\u2022 Total Magnification:100\u00d7(observation),400\u00d7(test)
\n\u2022 Test range:200\u03bcm
\n\u2022 Resolution:0.01\u03bcm
\n\u2022 Digital Display:8″ color touchscreen
\nXY Stage table:Size:100\u00d7100\u339c-Travel distance:25\u00d725
\n\u339c-Resolution:0.01mm
\n\u2022 Power Supply:AC220V,60\/50Hz
\n\u2022 Machine power consumption:\u226420W
\n\u2022 Machine dimensions (mm):200x550x500
\n\u2022 Case dimensions (mm):400x630x840
\n\u2022 Weight (Net \/ Gross) kg:38\/52<\/p>\n<\/p>\n
\n1000gf
\n\u2022 Min measuring unit: 0.01\u03bcm
\nConversion Scale: HRA, HRB, HRC, HRD, HRF, HV,
\nHK, HBW, HR15N, HR30N, HR45N, HR15T, HR30T,
\nHR45T
\n\u2022 Hardness measuring range: 8~2900HV
\nMethod of testing force applied: Automatic (loading,
\nDwelling , unloading)
\n\u2022 Turret Type: Automatic
\nTest microscope magnification: 100X\uff08observation,
\nmeasuring\uff09,400X(Measuring)
\n\u2022 Test force dwell time: 0~60s
\nX-Y test sets Dimension: 100*100mm Maximum
\nMovement\uff1a25*25mm
\n\u2022 Data output: Touch-screen display\uff0cUSB disk save
\n\u2022 Maximum specimen height: 90mm
\nDistance from the center to the outer wall of the
\nindenter: 95mm
\n\u2022 Power supply: AC220V+5%\uff0c50-60Hz
\n\u2022 Dimensions: 630*290*680mm
\n\u2022 Net Weight: 53Kg
\n\u2022 Language: Turkish, English
\n\u2022 Digital display: 8\u201c Color Touchscreen<\/p>\n\u5e03\u6c0f\u786c\u5ea6\u6d4b\u8bd5\u4eea<\/strong><\/h2>\n
<\/p>\n
\n\u2022 Load Selection:Automatic
\n\u2022 Test Method:Brinell
\n\u2022 Digital display: 15 \u201c Color Touchscreen
\n\u2022 Load Application:Automatic
\n\u2022 Measuring system:Digital camera
\n\u2022 Depth of Throat:200 mm
\n\u2022 Max. Test height:430 mm
\n\u2022 Power supply:220V, 50Hz
\n\u2022 Machine Dimensions:320x1500x800 mm
\n\u2022 Case Dimensions :980x1050x1750 mm
\n\u2022 Weight (net\/gross):500 \/ 590 kg<\/p>\n<\/p>\n
\n\u2022 1-Address information
\n\u2022 2-Customer Information
\n\u2022 3-Hardness Test procedures,
\n\u2022 4-Logged; program user,
\n\u2022 5-User management,
\n\u2022 6-Database Backup and Restore
\n\u2022 7-Language Selection,
\n\u2022 8-Program update,
\n\u2022 9-Program exit
\n\u2022 Digital Camera
\n\u2022 5 MP digital camera<\/p>\n