{"id":185,"date":"2024-04-11T15:36:22","date_gmt":"2024-04-11T07:36:22","guid":{"rendered":"https:\/\/www.bihec.com\/monarchinstrument\/?p=185"},"modified":"2024-04-11T15:36:22","modified_gmt":"2024-04-11T07:36:22","slug":"%e7%be%8e%e5%9b%bd-monarch-instrument-act-1b-%e9%9d%a2%e6%9d%bf%e8%bd%ac%e9%80%9f%e8%a1%a8-2","status":"publish","type":"post","link":"https:\/\/www.bihec.com\/monarchinstrument\/%e7%be%8e%e5%9b%bd-monarch-instrument-act-1b-%e9%9d%a2%e6%9d%bf%e8%bd%ac%e9%80%9f%e8%a1%a8-2\/","title":{"rendered":"\u7f8e\u56fd Monarch Instrument ACT-1B \u9762\u677f\u8f6c\u901f\u8868"},"content":{"rendered":"
<\/p>\n
<\/p>\n
<\/p>\n
ACT-3X \u9762\u677f\u8f6c\u901f\u8868\u662f\u4e00\u6b3e\u529f\u80fd\u5f3a\u5927\u7684 NIST \u6821\u51c6\u3001\u5b8c\u5168\u53ef\u7f16\u7a0b\u7684\u8f6c\u901f\u8868\u548c\u7d2f\u52a0\u5668\u3002\u5b83\u63a5\u53d7\u6765\u81ea\u6240\u6709 Monarch \u901f\u5ea6\u4f20\u611f\u5668\u6216\u4efb\u4f55\u6807\u51c6 TTL \u751f\u6210\u8bbe\u5907\u7684\u8f93\u5165\u3002\u8be5\u88c5\u7f6e\u7531 120\/240 V \u4ea4\u6d41\u8f93\u5165\u7535\u6e90\u6216 12 \u6216 24 V \u76f4\u6d41\u8f93\u5165\u7535\u6e90\uff08\u53ef\u9009\uff09\u4f9b\u7535\u3002\u53ef\u901a\u8fc7 5 \u4e2a\u524d\u9762\u677f\u6309\u94ae\u6216\u4f7f\u7528\u514d\u8d39\u4e0b\u8f7d\u7684\u00a0<\/span>PM \u8fdc\u7a0b\u8f6f\u4ef6<\/span><\/strong>\u8f7b\u677e\u8fdb\u884c\u7f16\u7a0b\u3002\u8bbe\u7f6e\u4e3a\u5355\u901a\u9053\u76d1\u63a7\u3002\u53ef\u7f16\u7a0b\u6bd4\u4f8b\u56e0\u5b50\uff0c\u83dc\u5355\u9009\u62e9\u6bcf\u8f6c\u591a\u4e2a\u8109\u51b2\u3001\u7ebf\u6027\u901f\u7387\u3001\u5355\u4e8b\u4ef6\u8df3\u95f8\u901f\u5ea6\uff08\u4f7f\u7528\u8f85\u52a9\u8f93\u5165\uff09\u548c RPM \u53d8\u5316\u7387\u3002TTL \u8109\u51b2\u4e2d\u7ee7\u5668\u8f93\u51fa\u4e3a\u6807\u51c6\u914d\u7f6e\u3002\u5efa\u8bae\u4f7f\u7528\u7684\u4f20\u611f\u5668\u6709 PN -W\uff08= \u9540\u9521\u5f15\u7ebf\uff09\u3001<\/span>ROS-W<\/span>\u3001<\/span>ROS-HT-W-25<\/span>\u3001\u00a0\u00a0<\/span>P5-11<\/span>\u3001<\/span>PS-12<\/span>\u3001\u00a0\u00a0<\/span>M-190W<\/span>\u3001\u00a0\u00a0<\/span>IRS-W<\/span>\u3001\u00a0\u00a0<\/span>ROLS-W\u00a0<\/span>\u3001<\/span>\u00a0RLS-W<\/span>\u3001\u00a0\u00a0<\/span>SLS-115\/230<\/span>\u3001<\/span>CSLS<\/span>\u548c\u00a0<\/span>GE-200HP<\/span>\u71c3\u6c14\u53d1\u52a8\u673a\u4f20\u611f\u5668\uff08\u5e26\u653e\u5927\u5668\uff09\u3002<\/span><\/p>\n \u6240\u6709\u578b\u53f7 – \u901a\u7528\u8f93\u5165<\/span>\uff0c\u901a\u8fc7\u5149\u5b66\u3001\u7ea2\u5916\u3001\u6fc0\u5149\u3001\u63a5\u8fd1\u548c\u78c1\u4f20\u611f\u5668\u6216\u76f4\u63a5 TTL \u548c 200 mV \u81f3 50 V \u4ea4\u6d41\u4fe1\u53f7\u8fdb\u884c\u975e\u63a5\u89e6\u5f0f\u64cd\u4f5c<\/span><\/p>\n ACT-3X \u9762\u677f\u8f6c\u901f\u8868<\/span><\/strong><\/p>\n Optional: 12 or 24 V dc +\/-20%, isolated,\u00a08VA<\/td>\n<\/tr>\n High Temp –\u00a0ROS-HT-W-25<\/p>\n Proximity –\u00a0P5-11,\u00a0PS-12<\/p>\n Magnetic –\u00a0M-190W\u00a0or\u00a0MT-190W<\/p>\n Infrared –\u00a0IRS-W<\/p>\n Laser –\u00a0ROLS-W,\u00a0RLS-W,\u00a0SLS-115\/230,\u00a0CSLS<\/p>\n Inductive –\u00a0GE200-HP Gas Engine\u00a0(requires amplifier)<\/td>\n<\/tr>\n Menu-selectable polarity<\/td>\n<\/tr>\n Front panel pushbutton programmable for full scale and offset RPM ranges<\/td>\n<\/tr>\n Front panel pushbutton programmable<\/p>\n Hysteresis, deadband, and low limit lockout are programmable; relays can be set as a fail-safe<\/p>\n Alarms can be reset manually or automatically; remote reset via the auxiliary input<\/td>\n<\/tr>\n (If no communications are ordered, the unit can still be programmed with an optional USB programming cable.)<\/td>\n<\/tr>\n Humidity: maximum relative humidity 80% for temperatures up to 31 \u00b0C, decreasing linearly to 50% relative humidity at 40 \u00b0C<\/td>\n<\/tr>\n \u7f8e\u56fd Monarch Instrument ACT-1B \u9762\u677f\u8f6c\u901f\u8868 \u63cf\u8ff0 ACT-3X \u9762\u677f\u8f6c\u901f\u8868\u662f\u4e00\u6b3e\u529f\u80fd\u5f3a\u5927\u7684 NIST \u6821\u51c6\u3001\u5b8c\u5168\u53ef\u7f16\u7a0b\u7684\u8f6c\u901f\u8868\u548c\u7d2f\u52a0\u5668\u3002\u5b83\u63a5\u53d7\u6765\u81ea\u6240\u6709 M <\/p>\n","protected":false},"author":16,"featured_media":186,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_vp_format_video_url":"","_vp_image_focal_point":[]},"categories":[21],"tags":[20,7,11,6,9,13,16,5,18],"yoast_head":"\n\u7279\u5f81<\/span><\/h2>\n
\n
\u53c2\u6570*<\/h2>\n
\n\n
\n <\/td>\n <\/td>\n<\/tr>\n \n Speed Range<\/strong><\/td>\n 5-999,999 RPM (speeds below 5 RPM possible with multiple pulses per revolution)<\/td>\n<\/tr>\n \n Input Frequency Range<\/strong><\/td>\n 0.083 Hz to 80\u00a0kHz<\/td>\n<\/tr>\n \n Totalizer\/Counter<\/strong><\/td>\n Display Range: 0.001 to 99,999<\/td>\n<\/tr>\n \n Input Configuration<\/strong><\/td>\n Universal inputs: 1 to 9,999 pulses per revolution
\nfront panel pushbutton programmable TTL input and 1.1 V to 50 V ac signals, Opt: -1 to -50 V\u00a0dc<\/td>\n<\/tr>\n\n Accuracy<\/strong><\/td>\n +\/-0.001% of reading or +\/-1 displayed resolution (standard gate),
\n+\/-0.06% of reading or +\/-1 displayed resolution (fast gate)<\/td>\n<\/tr>\n\n Resolution<\/strong><\/td>\n Up to 0.001 RPM, 10 RPM (100,000 to 999,990 RPM)<\/td>\n<\/tr>\n \n Display<\/strong><\/td>\n 5-digit, 0.56 in. [14 mm] high red LED<\/td>\n<\/tr>\n \n Display and Output Update<\/strong><\/td>\n Menu-selectable between 0.5 seconds above 120 RPM, 1 second above 60 RPM, and 1.5 seconds above 40 RPM<\/td>\n<\/tr>\n \n Max Measurement Rate<\/strong><\/td>\n Up to 100 times per second (Standard Gate) or up to 1000 (Fast Gate) dependent on the input frequency; input must be measurement rate<\/td>\n<\/tr>\n \n Scaling<\/strong><\/td>\n Programmable scaling: 0.0001 to 9999.9 (front panel pushbutton programmable)<\/td>\n<\/tr>\n \n Decimal Point<\/strong><\/td>\n User-selectable (0-3) decimal places max (front panel pushbutton programmable)<\/td>\n<\/tr>\n \n Memory<\/strong><\/td>\n Maximum, minimum, and last reading recall from front panel pushbuttons<\/td>\n<\/tr>\n \n Dimensions<\/strong><\/td>\n 1\/8 DIN by 4.5 in. [114 mm] deep
\nPanel cutout: 3.58 in. x 1.74 in. [91 x 44 mm]<\/td>\n<\/tr>\n\n Input Power<\/strong><\/td>\n Standard: 100-240 V ac +\/-10%, 50\/60 Hz<\/p>\n \n Inputs<\/strong><\/td>\n Universal input for optical, proximity, two-wire or three-wire magnetic, infrared, or laser sensors; TTL input or 3.3\u00a0V ac to 50 V ac input (The standard input is 1 pulse per revolution.)<\/td>\n<\/tr>\n \n Sensor Excitation<\/strong><\/td>\n 5 V dc or optional 12 or 24 V dc to sensor<\/td>\n<\/tr>\n \n Recommended Sensors<\/strong><\/td>\n LED –\u00a0ROS-W<\/p>\n \n Pulse Repeater Output<\/strong><\/td>\n Standard, 0 to 5 V TTL compatible; one pulse out for each pulse in<\/p>\n \n Communications<\/strong><\/td>\n Bidirectional RS232C, USB, or Ethernet interface<\/td>\n<\/tr>\n \n Analog Output\u00a0<\/strong>(optional)<\/strong><\/td>\n Voltage (AO): 0 to 5 V dc, 5 mA max load (isolated\u00a0or non-isolated) or Current (IO): 4 to 20 mA, 500\u00a0ohm,\u00a6 max load. (or non-isolated), 1 to 5 V dc possible using 250\u00a0ohm resistor) 16-bit resolution<\/p>\n \n Pulse Output\u00a0<\/strong>(optional)<\/strong><\/td>\n Repeater pulse output: TTL pulse switching between +5 V and ground<\/td>\n<\/tr>\n \n Alarm Capability<\/strong><\/td>\n Two-alarm setpoints: High or Low
\nalarm limits, latching or non-latching<\/p>\n\n Alarm Outputs<\/strong><\/td>\n Two Form C relay contacts, rated 1 A at 115 V ac or 230 V ac<\/td>\n<\/tr>\n \n Remote Programming<\/strong><\/td>\n Remote programming is possible using an optional communications interface and PM Remote Software<\/p>\n \n Environmental<\/strong><\/td>\n Indoor use only, installation category II per IEC 664 temperature: -10 \u00b0C to 50 \u00b0C operating per IEC 61010-1<\/p>\n \n Electrical Safety<\/strong><\/td>\n Meets EN61010-1:2001, EC low voltage directive 72\/23\/EEC and 89\/336\/EEC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n