111D-XD-TU1/16(HC)(SS)(?”SWAG)-4/20-ISB-220V flow meter流量計

Consisting of flow sensing transducer, separate electronics package, and interconnect cable 


 Same as Serial Number 94124-4 


 Flow Data: 


 Fluid: 98% Sulfuric Acid (See Note 1) 


 Customer Line Size: Same as Previous 


 Customer Flow Range: 0-0.36 lph 


 Calibrated Flow Range: 0.036-0.36 lph 


 Temperature-Max: 60 C 


 Temperature-Operating Range: 38 C 


 Pressure-Max: 1 mPag 


 Pressure-Operating range: 0.11 mPag 


 Viscosity: – 


 Specific Gravity: 1.818 


 Instrument Data: 


 Transducer Type: TU 


 Wetted Material: Hastelloy-C276 (See Note 2) 


 Shell Material: Stainless Steel 


 Fittings: 1/4-inch HC276 Swagelok fittings 


 Local Display: Flow Rate 


 Calibration Units: lph 


 Output(s): linear 4 to 20 milliamp 


 Input Power: 220 VAC 50 Hz 


 Electronics Enclosure: None – Mounting Plate Only 


 Cable Length: 10 ft; up to 200 ft available at ¥28.00/ft 


 Notes: 


 1. Intek may use a substitute calibration fluid while calibrating your instrument. 


 If this is the case, a simple field calibration adjustment will be necessary to guarantee the highest levels of accuracy. 


 2. The user is responsible for the selection of process-wetted materials in view of their corrosion resistance. Intek, Inc. 


 makes no guarantees and assumes no liability for the corrosion resistance of the materials selected here for the application described above.