adamczewski eletronische messtechnik-Pulse and Frequency Measurement 脈沖和頻率測量 模擬標準信號輸出 開關和脈沖輸出 分頻或倍頻脈沖 模擬標準信號轉脈沖 接點保護 耦合繼電器

對頻率或脈沖序列(例如流量、能量或旋轉速度)進行測量和轉換,將其轉換為模擬標準信號,同時進行限值處理。

模擬標準信號輸出

AD-FM 300 GT,AD-FM 600 GT

產品介紹

AD-FM 300 GT(1通道)和AD-FM 600 GT(2通道)是帶有集成顯示單元的可自由編程頻率/模擬測量變送器。由于其對輸入頻率和每通道的最多2個模擬輸出(電流/電壓)或可評估的數字輸出的多功能處理,該設備非常適用于同時顯示瞬時流量并具有可評估的計數脈沖輸出的水表(包括主表和子表)。特別是對于帶有旁通的大型水表,AD-FM 600 GT中集成了一個經過縮放的求和。既輸出瞬時流量,又輸出計數數量。可以切換低水平抑制。

產品參數

Digital inputs
InputNAMUR (EN 60947-5-6), reed contact, open-collector, 3-lead opto-transmitteror 24V active
Input frequencyMin. 0 … 10 mHz; max. 0 … 10 kHz
Frequency generator supplyActive: max. 10V/10mA; NAMUR:8V/8mA
Contact debouncingActivatable, pulse duration > 40 ms
Current outputs
Output range0 … 20 mA; 4 … 20 mA
Max. burden400 Ohm
Residual ripple< 50 μAss
Voltage outputs
Output range0 … 10 V, 2 … 10 V
Min. burden10 kOhm
Residual ripple< 20 μVss
Relay outputs
Maximum switching load AC250 V, 2 A
Maximum switching load DC50 V, 2 A
Contact constructionChangeover contact
Switching operations mechanical10000000
At 230V/2A AC, cos(phi)=1600000
At 230V/2A AC, cos(phi)=0,4200000
At 24V/1 A DC200000
Display
Graphic-LCD122×32 Pixel, background lit
Digital display5-digit, can be configured
Display functions each channelInput frequency, scaled instantaneous measuring value, quantity impulse, scaled dimension as quasi analogue bar
Accuracy
Unit0,3%
Temperature influence<100 ppm / K
Update rate1 s
Supply
Supply voltage20 … 253 V DC / 50 … 253 V AC
Max. power consumption4,5 W / 7,5 VA
RS485-Bus
Software protocolModbus-RTU
Data format19200, e, 8, 1
Max. bus users247
Bus termination120 ohms both sides at the end
Max. length of bus500 m (no stubs)
CableTwisted and shielded
Housing
Dimensions (WxHxD)105x90x58 mm
Type of protectionIP 20
Connection methodScrew clamp
Terminals, wire cross section2,5 mm2 flex wire / 4 mm2 one wire
Bolting torque terminals0,6 Nm
Skinning length6 mm
Weight~ 300 g
Manner of fastening35 mm DIN rail
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … 70 °C (no condensation)
EMC
Product family standardEN 61326-1
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
In a critical EMC environment, shielded encoder cables are recommended.
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input/output1 kV RMS (1 min.)
Signal/auxiliary voltage3 kV RMS (1 min.)

開關和脈沖輸出

AD-FM 300/600 GA, AD-FM 300/600 FE

產品介紹

AD-FM 300 FE/GA(1通道)和AD-FM 600 FE/GA(2通道)是帶有面板安裝顯示單元(FE)和DIN導軌安裝(GA)的可自由編程的頻率/模擬測量變送器。通過其對輸入頻率的多功能處理以及每通道的最多2個模擬輸出(電流/電壓)和可評估的數字輸出,該設備非常適用于同時顯示瞬時流量并具有可評估的計數脈沖輸出的水表(包括主表和子表)。特別是對于帶有旁通的水表,AD-FM 600 FE/GA中集成了一個經過縮放的求和。可以切換低水平抑制。瞬時流量和計數數量都會被輸出和累加。

產品參數

Digital inputs
InputNAMUR (EN 60947-5-6), reed contact, open-collector, 3-lead opto-transmitteror 24V active
Input frequencyMin. 0 … 10 mHz; max. 0 … 10 kHz
Frequency generator supplyActive: max. 13,5V (max. 20mA); NAMUR:8V/8mA
Contact debouncingActivatable, pulse duration > 40 ms
Current outputs
Output range0 … 20 mA; 4 … 20 mA
Max. burden400 Ohm
Residual ripple<50 μAss
Voltage outputs
Output range0 … 10 V, 2 … 10 V
Min. burden10 kOhm
Residual ripple<20 μVss
Relay outputs
Maximum switching load AC250 V, 2 A
Maximum switching load DC50 V, 2 A
Contact constructionChangeover contact
Switching operations mechanical10000000
at 230V/2A AC, cos(phi)=1600000
at 230V/2A AC, cos(phi)=0,4200000
at 24V/1 A DC200000
Display
Graphic-LCD122×32 Pixel, background lit
Digital display5-digit, can be configured
Display functions each channelInput frequency, scaled instantaneous measuring value, quantity impulse, scaled dimension as quasi analogue bar, channel description and scaling unit in plain language
Accuracy
Unit0,3%
Temperature influence<100 ppm / K
Response time~70 ms
Supply
Supply voltage20 … 253 V DC / 50 … 253 V AC
Max. power consumption4 W / 5 VA
Housing front mounting
Manner of fasteningPanel-mount-case (DIN 43 700)
Type of protectionIP 65
Connection methodScrew clamp
Dimensions (WxHxD)96x48x131 mm
Front panel cut out92×44 mm
Switchboard thickness1,5-10 mm
Weight~230 g
DIN rail housing
Manner of fasteningDIN rail 35mm (EN 50022)
Type of protectionIP 20
Connection methodScrew clamp
Dimensions (WxHxD)100x74x119 mm
Weight~230 g
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … 70 °C (no condensation)
EMC
Product family standardEN 61326-1
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
In a critical EMC environment, shielded encoder cables are recommended.
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input/output2 kV RMS (1 min.)
Signal/auxiliary voltage4 kV RMS (1 min.)

分頻或倍頻脈沖

AD-FM 255 GVD

產品介紹

頻率測量轉換器AD-FM 255 GVD提供了一個觸發器或一個接觸器,并將其脈沖序列轉換為與之成比例的模擬信號。輸出信號獨立于連接負載,直到達到最大值。所有測量范圍和輸出都可以自由參數化。這可以通過可選的操作面板AD-VarioControl或通過編程軟件AD-Studio進行。輸入、輸出和供電電壓在高隔離度的情況下相互分離。

產品參數

Digital input
InputNAMUR (EN 60947-5-6), reed contact, open-collector, 3-lead opto-transmitteror 24V active
Input frequencyMin. 0 … 10 mHz; max. 0 … 10 kHz
Frequency generator supplyActive: 8V / 8mA
Kontaktentprellung (activatable)40 ms
Output current
Output range0 … 20 mA
Max. burden400 Ohm
Residual ripple< 50 μAss
Output voltage
Output range0 … 10 V
Min. burden10 kOhm
Residual ripple<20 μVss
Accuracy
Unit<0,3%
Temperature influence<100 ppm / K
Response timeApprox. 70 ms
Relay output
Contact typePotential-free changeover
Max. AC-breaking capacity250 V AC, 2 A AC, 50Hz
Max. DC-breaking capacity50 V DC, 2 A DC
Switching operations
Mechanical107
AC: 230V / 2A, cos(phi)=16 * 105
AC: 230V / 2A, cos(phi)=0,42 * 105
DC: 24V / 1A2 * 105
Semiconductor output (optional)
Max switching voltage30 V DC
Max. switching current50 mA DC
Voltage drop< 1 V
Supply
Voltage range AC50 … 253 V AC, 50/60 Hz
Nominal voltage AC230 V AC
Voltage range DC20 … 253 V DC
Nominal voltage DC24 V DC
Power consumption AC / DC3,7 VA / 2,1 W
Housing
Dimensions (WxHxD)23x110x134 mm
With operating module (bxhxt)23x110x138 mm
Type of protectionIP 20
Connection methodDetachable terminal clamp
Terminals, wire cross section2,5 mm2 flex wire / 4 mm2 one wire
Bolting torque terminals0,5 Nm
Weight~ 140 g
Manner of fastening35 mm DIN rail 35mm
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … 70 °C (no condensation)
EMC
Product family standard?1)EN 61326-1
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
In a critical EMC environment, shielded encoder cables are recommended.
1)During electromagnetic disturbance minor changes in output signal are possible.
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input/output2 kV RMS (1 min.)
Signal/auxiliary voltage3 kV RMS (1 min.)

模擬標準信號轉脈沖

AD-AI 200 GVC

產品介紹

模擬脈沖轉換器AD-AI 200 GVC將模擬信號轉換為數量信號,例如對應于流量或吞吐量。這些脈沖可以通過內部繼電器輸出,或者選擇性地通過更快的晶體管輸出。AD-AI 200 GVC配備了一個緊湊的開關電源,在廣泛的供電電壓范圍內高效工作。該轉換器可以通過具有可用參數軟件AD-Studio的PC進行配置。但是,它也可以預設交付。

產品參數

Input
Input current0/4 … 20 mA (Rin: 50 Ohm) resolution 10 Bit
Input voltage0/2 … 10 V (Rin: 100 kOhm) resolution 10 Bit
Relay output
Max. load AC250 V / 2 A (cos phi = 1)
Max. load DC50 V / 1 A (resistive load)
Cycles AC- load2 A (cos phi = 1): ca. 110000
Cycles DC- load1 A (resistive load): ca. 100000
Pulse duration0,5 … 5 s
Transistor output (optional)
Max. load DC30V / 50mA
Pulse duration0,05 … 5 s (50% duty cycle at high frequency)
Supply
Voltage range20 … 253 V DC / 50 … 253 V AC
Power consumptionMax. 1,5 W / 2,6 VA (50 Hz)
Accuracy
Accuracy< 0,2 %
Input (AD-Converter)Ca. 0,1 % of full scale
Housing
Dimensions (WxHxD)18x110x134 mm
Type of protectionIP 20
Connection methodDetachable terminal clamp (2,5 mm2 flex wire / 4 mm2 one wire)
Bolting torque screw terminals0,5 Nm
Weight135 g
Manner of fasteningDIN rail 35mm (EN 50022)
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … 70 °C (no condensation)
EMC
Product family standardEN 61326-1
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standardEN 61010-1
Galvanic isolation, test voltages
Input / output4 kV (1 min.)
Signal / supply unit4 kV (1 min.)
Protection circuits
InputElectrical surge protection
Power supplyElectrical surge and reverse current protection
Relay outputNo protection
Transistor outputElectrical surge protection

接點保護

AD-KV 100 GS, AD-KV 100 GS-O

產品介紹

接點保護脈沖繼電器(開關放大器)主要用于保護弱傳感器接點或放大二進制傳感器信號。AD-KV 100 GS(o)在輸出上提供輸入脈沖,暫時放大1:1。同時,它將經過處理的輸入信號轉換為具有恒定可調長度的輸出脈沖(通過前面的調節器進行調整)。典型的輸入信號包括簧片開關、根據Namur標準(DIN EN 60947-5-6)的信號發生器、TTL電平、電壓信號或電阻變化。輸出處有耐用且無電位的觸點。版本AD-KI 100 GSO具有無磨損的晶體管輸出,通過光耦合器也進行了電氣隔離。此外,該設備還配備了一種電子寬范圍電源,可以從廣泛的供電電壓范圍內高效供應AD-KV 100 GS(o)的能量。

產品參數

Impulse input
Min. pulse width2 ms
Namur supply voltageCa. 8,2 V DC
Logic level for Namur signalsLow < 1,2 mA … High > 2,1 mA
Max. input voltage (active)30 V DC
Logic level for active signalsLow < 5 V … High > 20 V
Type of contactPotential-free
Pulse processing
Output pulse lengthOutput follows input 1:1
Relay outputs
Maximum switching load AC250 V, 2 A
Maximum switching load DC50 V, 2 A
Contact constructionPotential-free changeover
Switching operations mechanical10000000
At 230V/2A AC, cos(phi)=1600000
At 230V/2A AC, cos(phi)=0,4200000
At 24V/1 A DC200000
Semiconductor outputs
Max switching voltage30 V DC
Max. switching current50 mA DC
Working voltage at pullup10 … 30 V DC
Internal pullup5 kOhm
Supply
Voltage range AC50 … 253 V AC, 50/60 Hz
Nominal voltage AC230 V AC
Voltage range DC20 … 253 V DC
Nominal voltage DC24 V DC
Power consumption AC / DC3 VA / 2W
Transmission behaviour
Temperature influence100 ppm/K
Response time~ 5 ms
Housing
Dimensions (WxHxD)23x78x103 mm
Type of protectionIP 20
Connection methodScrew clamp
Terminals, wire cross section2,5 mm2 flex wire / 4 mm2 one wire
Bolting torque terminals0,5 Nm
Weight~ 115 g
Manner of fastening35 mm DIN rail 35mm
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … 70 °C (no condensation)
EMC
Product family standardEN 61326-1?1)
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input / output3,75 kV, 50 Hz (1 min.)
Signal / supply unit4 kV, 50 Hz (1 min.)
Protection circuits
InputElectrical surge protection
Power supplyProtection against over voltage, over temperature and reverse polarity

耦合繼電器

AD-KR 11 GX, AD-KR 12 GX, AD-KR 22 GX

產品介紹

AD-KR 11 GX、AD-KR 12 GX(1通道)和AD-KR 22 GX(2通道)系列的耦合繼電器通過24V輔助電壓實現對接點消息的電氣隔離和放大。在前面,繼電器的工作狀態通過紅色發光二極管指示。一個自由輪二極管和反極性保護是內置的。由于其狹窄的構造類型,整體外殼寬度僅為6.2毫米,實現了高的裝箱密度。

產品參數

Input
Nominal voltage24 V DC
Voltage range20 … 30 V DC
Response time6 ms
Fallback time6 ms
Relay output
Maximum switching load AC250 V, 2 A
Maximum switching load DC50 V, 2 A
Switching capacity AC< 100 VA
Switching capacity DC< 100 W
Switching frequency< 1 Hz
Switching operations mechanical10000000
At 230V/2A AC, cos(phi)=1600000
At 230V/2A AC, cos(phi)=0,4200000
At 24V/1 A DC200000
Contact construction
AD-KR 11 GX1 potential-free changeover
AD-KR 12 GX2 potential free contacts
AD-KR 22 GX2 potential free contacts
Housing
Dimensions (WxHxD)6,2 x 92 x 101 mm3
Type of protectionIP 20
Connection methodScrew clamp
Terminals, wire cross section2,5 mm2 flex wire / 4 mm2 one wire
Bolting torque terminals0,5 Nm
Weight~ 100 g
Manner of fasteningDIN rail mounting 35mm, EN 50022
Environmental conditions
Ambient temperature-10 … 50 °C
Storage and transport-10 … +70 °C (no condensation)
EMC
Product family standardEN 61326-1
Emitted interferenceEN 55011, CISPR11 Cl. B, Gr. 1
Electrical safety requirements
Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2
Galvanic isolation, test voltages
Input to relay1,5 kV, 50 Hz (1 min)
Relay to relay1,5 kV, 50 Hz (1 min)
Protection circuits
InputElectrical surge protection