according to drawing 1b and 3b | |
Measuring range: | 0.6 … 12350 l /min or 0.04 … 741 m3/h |
Working pressure range: | up 16 bar / 1.6 MPa g. |
Working temperature range: | -10 … +140 °C |
Medium: | air (compressed air), nitrogen, methane, natural gas, argon, carbon dioxide, helium … |
Displayed meaurement categories: | standard flow rate [m3/h] or [l/min], standard volume [m3], standard flow velocity [m/s] |
IP protection: | IP65 (connection housing) |
Ex protection: | ATEX category 3G and 3D (Zone 2 and 22) (option) |
Sensor outputs: | analog output 4 … 20 mA flow proportional; relay for quantity pulse; RS232 interface |