VISCOJET VJ1 ?SPECIFICATION
|
|
|
|
PERFORMANCE
|
Range |
0 – 1,000 cP |
|
Measurement Time |
1 second |
|
Accuracy |
1% of reading or +/- 0.1cP |
|
Repeatability |
0.3% of reading or +/- 0.05cP |
OUTPUTS / INPUTS
|
Analog |
2 × 4-20mA configurable, representing viscosity, ref. viscosity, or temperature |
|
Digital |
RS485 ModBus Data Link to host system or PC running ViscoLink |
|
Power |
24v DC @ 80mA |
TEMPERATURE
|
Integral Thermometer |
Integrated temperature measurement |
|
Standard Range |
-50 °C to 150 °C |
|
Extended Range |
To order for greater than 150 °C * |
PRESSURE
|
Standard Range |
50 Bar |
|
Extended Range |
To order for greater than 50 bar * |
PIPE CONNECTION
|
Standard Fitting |
3/4” or 1” BSPP / NPS, ?1.5” cone-seat (Swagelok?) |
|
Special Fitting |
Non-standard process connection to order * |
ELECTRICAL CONNECTION
|
Cable Length |
As required – not affected by cable length up to 1000m |
|
Cable Type |
Any standard instrument cable |
CONSTRUCTION
|
All welded, crevice-free |
MATERIALS
|
Head |
SS316 ( EN 1.4401) |
|
Sensor |
SS316 ( EN 1.4401) |
|
Sensor/Fitting Options: |
Alloy C22 (EN 2.4602) |
|
|
Alloy C276 (EN 2.4819) |
|
|
S32750 Duplex Steel (EN 1.4410) |
|
Special Materials: |
Non-standard materials to order * |
SURFACE FINISH
|
Standard |
N6 0.8 Ra |
|
Special Finish |
Non-standard finish options and coatings to order * |
WEIGHT
|
|
3Kg |
INGRESS PROTECTION
|
Standard |
IP67 |
SOFTWARE
|
ViscoLink data viewing and logging PC software |
|
|
|
* SPECIAL OPERATIONS
|
Custom variations to instrument specification and dimensions routinely provided by our dedicated Special Operations division |
|
|
|
As it is Hydramotion’s policy to continuously develop and improve its products, some specifications may change without notice |