德國藍姆達Lambda EP500e VIP真空絕熱板導熱系數(shù)儀防護熱板法導熱系數(shù)儀

λ-Meter EP500E,防護熱板法導熱系數(shù)儀, 德國Lambda,藍姆達, VIP真空絕熱板, xps保溫板導熱系數(shù),導熱系數(shù)測定儀,導熱系數(shù)測量儀

導熱系數(shù)測試工具λ-Meter EP500e(保護熱板儀)是一個根據(jù)護熱板法的操作測試導熱系數(shù)的絕對值的工具,傳熱阻力以及增值系數(shù)粘度值和u值絕緣材料、建筑材料和其他產(chǎn)品。測試按照ISO 8302, EN 12667, ASTM C177和測試機構要求的高測量精度進行。根據(jù)現(xiàn)場生產(chǎn)控制的要求,在短時間內(nèi)完成測試。

Measurement Mode single measurement or series of up to 3 single measurements
at different arbitrary temperatures
Measurement Temperaturefreely selectable in the range of 10 °C up to 40 °C
optionaldown to -10? and up to 50 °C
Temperature Differencefreely selectable in the range of 5 K up to 15 K
Measurement RangeR = 0,250…14,0 m2·K/W and λ = 1…250 mW/m·K
optionalR = 0,125…14,0 m2·K/W and λ = 1…500 mW/m·K
optionalR = 0,025…0,250 m2·K/W and λ = 0,25…2,0 W/m·K
Sample Thickness10 up to 120 mm
optional<10 up to 200 mm
Sample Dimensionsoptimal: 500 x 500 mm2, measurement zone size at minimum
Measurement Zoneselectable: 250 x 250 mm2, 200 x 200 mm2, 150 x 150 mm2
Reproducibility< 0,5 % (mostly < 0,2 %)
Measurement Accuracy< 1,0 % (mostly < 0,7 %)
The prototype had been used for comparative tests by the FIW Munich (see no: CE 1-1/99).
Dimensions?(Length x Width x Height)63 x 63 x 88 cm3
Massca. 85 kg
Power Supply230 V / 50 Hz
Power Consumptionmax. 450 W
Protection Class / Degree of
Protection
I / IP 20
Cooling-/Heating unit:12 air-cooled high performance Peltier modules