Four positions Polymer Viscometer PSL-Rheotek

Four positions Polymer Viscometer PSL-Rheotek

The PSL Rheotek RPV-1 (4) four position polymer viscometer system is suitable for measuring the dilute solution viscosity of a wide range of polymers dissolved in acids, organic solvents or water, including PA, PET, PVC, PLA, PBT, PC, PE, PP, Cellulose Acetate, Inks, bio-polymers and other.

RPV-1 systems are designed to be integrated with the SP-1 Sample Preparation system for polymers.

Other options include SD-1 Sample dissolution and RSS Rheotek Smart Sampler.

The PSL Rheotek RPV-1 (4) provides a reliable and precise system for measuring dilute solutions of polymers.
The RPV-1 automates the manual steps set out in standard methods, minimizing the variability of results.
Systems can be configured with 1 to 4 measuring positions. Other options include sample preparation,
sample dissolution and auto sampler.
Flow times are measured automatically using ASTM Ubbelohde viscometer tubes supplied with ISO 17025
certificates of calibration.
Cleaning is carried out in-situ utilizing solvents and a safe vacuum system.
The comprehensive RPV-1 software program records all measurement data as well as calculating a wide
range of results.

Standard Practice:
ASTM D2857 Determination of the dilute solution viscosity of polymers.
?
Test Methods General:
ISO 1628 Part 1 Determination of the reduced viscosity, intrinsic viscosity and K-value of polymers in dilute solution using glass capillary viscometers
?
Test Methods Polyamides (PA):
ASTM D789 Determination of the Relative Viscosity of Polyamide (PA)
ISO 307 Determination of viscosity number Polyamides
DIN 53727 – Bestimmung der Viskosit?t von L?sung, Polyamid (PA) in verdünnter L?sung.
?
Test Methods Poly (Ethylene Terephthalate) PET:
ASTM D4603 Determination of the Inherent Viscosity of Poly (Ethylene Terephthalate) PET
ISO 1628 Part 5 Determination of the viscosity number (reduced viscosity) of? Poly (Ethylene Terephthalate) PET, poly (butylene terephthalate) PBT, poly (cyclohexylenedimethylene terephthalate) PCT and poly (ethylene naphthalate) PEN.
DIN 53728 – Bestimmung der Viskosit?t von L?sung, bestimmung der Viskosit?tszahl von Polyeyhyleneterphthalat (PETP) oder Polybutyleneterephthalat (PBTP) in verdünnter L?sung.
?
Test Methods Poly Vinyl Chloride (PVC):
ASTM D1243 Determination of the Inherent Viscosity of vinyl chloride polymers in cyclohexanone.
ISO 1628 Part 2 Determination of the reduced viscosity (viscosity number) and K-value of PVC resins.
DIN 53726 – Bestimmung de Viskosit?tszahl und des K-Wertes von Vinylchlorid (VC) – Polymerisation.
JIS K 6722 Testing methods for poly vinyl chloride
?
Test Methods Cellulose Acetate:
ASTM D871 Testing Cellulose Acetate
ISO 1599 Determination of Viscosity Loss on moulding of Cellulose Acetate.
?
Other Test Methods:
ASTM D445 Standard Test Method for determination of kinematic viscosity
ISO 3104 Petroleum products – determination of kinematic viscosity
IP 71 Section 1 Kinematic Viscosity
Typical RPV Applications And Configurations?
Polymer

Test Method

Solvent

Concentration

Temperature

RPV Measuring Positions

PA

ASTM D789

Formic acid

8.4%

25°C

2 to 4

PA

ISO 307

Formic acid

0.5%

25°C

1 to 4

PA

ISO 307

Sulphuric acid

0.5%

25°C

1 to 4

PA

ISO 307

M-Cresol

0.5%

25°C

1 to 4

PET

ASTM D4603

Phenol/Tetrachloroethane

0.5%

30°C

1 to 4

PET

ISO 1628-5
DIN 53728

Phenol/Dichlorobenzene

0.5%

25°C

1 to 4

PET

ISO 1628-5

Dichloroacetic acid

0.5%

25°C

1 to 4

PVC

ASTM D1243

Cyclohexanone/THF

0.2%

30°C

1 to 4

PVC

ISO 1628-2
DIN 53726

?Cyclohexanone

0.5%

25°C

1 to 4

? ? ? ? ? ?

PSL Viscometer tube type: AKV Ubbelohde, or RPVm Ubbelohde

Part No. Ordering information
RPV-1 (4) PSL Rheotek Polymer Viscometer – four positions complete with viscometer bath, chiller, control module, four measuring heads, four filling stations, PC control system and PIAB vacuum system.
Part No. Options
RPVS010 RPV start up kit including glass vials (144 pcs) and plastic caps (500 pcs)
SIL-OIL Silicone bath oil
MIN-OIL Mineral bath oil
ACC-1 Anti-corrosive coating – required for sulfuric acid and DCA applications
TSC-1 Third cleaning option – required for sulfuric acid or custom applications.
SWC/U Split waste upgrade option
STATPACK RPV StatsPack extraction of results to PC or LIMS

特性粘度計請聯(lián)系15821107090, 專業(yè)工程師為您提供解決方案