Two positions Auto polymer system PSL-Rheotek
Integrated glass capillary viscometer system suitable for measuring the dilute solution viscosity of a wide range of polymers dissolved in acids, organic solvents or water, including PA, PET, PVC, PLA, PBT, PC, PE, PP, Cellulose Acetate, Inks, bio-polymers and other.
The PSL Rheotek RPV-1 Auto provides a reliable and precise system for measuring dilute solutions of polymers.
Auto systems not only combine the control of the sample preparation process but also the sample dissolution.
The RPV Auto system controls the heating and stirring times of polymer solutions, as well as cooling prior to
measurement.
Sample dissolution control is critical in order to ensure that polymer solutions, such as PET, do not degrade prior
to measuring their intrinsic viscosity.
The RPV-1 Auto automates the manual steps set out in standard methods, minimizing the variability of results.
Flow times are measured automatically using ASTM Ubbelohde viscometer tubes supplied with ISO 17025
certificates of calibration.
Cleaning is carried out in-situ utilizing solvents and a safe vacuum system.
The comprehensive RPV-1 Auto software program records all measurement data as well as calculating a wide
range of results.
Standard Practice: |
ASTM D2857 Determination of the dilute solution viscosity of polymers. |
? |
Test Methods General: |
ISO 1628 Part 1 Determination of the reduced viscosity, intrinsic viscosity and K-value of polymers in dilute solution using glass capillary viscometers |
? |
Test Methods Polyamides (PA): |
ASTM D789 Determination of the Relative Viscosity of Polyamide (PA) |
ISO 307 Determination of viscosity number Polyamides |
DIN 53727 PA Bestimmung der Viskosit?t von L?sung, Polyamid (PA) in verdünnter L?sung. |
? |
Test Methods Poly (Ethylene Terephthalate) PET: |
ASTM D4603 Determination of the Inherent Viscosity of Poly (Ethylene Terephthalate) PET |
ISO 1628 Part 5 Determination of the viscosity number (reduced viscosity) of? Poly (Ethylene Terephthalate) PET, poly (butylene terephthalate) PBT, poly (cyclohexylenedimethylene terephthalate) PCT and poly (ethylene naphthalate) PEN. |
DIN 53728 PET, PBT Bestimmung der Viskosit?t von L?sung, bestimmung der Viskosit?tszahl von Polyeyhyleneterphthalat (PETP) oder Polybutyleneterephthalat (PBTP) in verdünnter L?sung. |
? |
Test Methods Poly Vinyl Chloride (PVC): |
ASTM D1243 Determination of the Inherent Viscosity of vinyl chloride polymers in cyclohexanone. |
ISO 1628 Part 2 Determination of the reduced viscosity (viscosity number) and K-value of PVC resins. |
DIN 53726 PVC Bestimmung de Viskosit?tszahl und des K-Wertes von Vinylchlorid (VC) – Polymerisation. |
JIS K 6722 Testing methods for poly vinyl chloride |
? |
Test Methods Cellulose Acetate: |
ASTM D871 Testing Cellulose Acetate |
? |
Other Test Methods: |
ASTM D445 Standard Test Method for determination of kinematic viscosity |
ISO 3104 Petroleum products – determination of kinematic viscosity |
IP 71 Section 1 Kinematic Viscosity |
Polymer |
Test Method |
Solvent |
Concentration |
Temperature |
Auto Measuring Positions |
PA |
ISO 307 |
M-Cresol |
0.5% |
20°C |
1 or 2 |
PET |
ASTM D4603 |
Phenol/Tetrachloroethane |
0.5% |
30°C |
1 or 2 |
PET |
ISO 1648-5 |
Phenol/Dichlorobenzene |
0.5% |
25°C |
1 or 2 |
PET |
Dichloroacetic acid |
0.5% |
25°C |
1 or 2 |
|
PVC |
ASTM D1243 |
Cyclohexanone/THF |
0.5% |
30°C |
1 or 2 |
PVC |
ISO 1648-2 |
Cyclohexanone |
0.5% |
25°C |
1 or 2 |
? |
? |
? |
? |
? |
? |
Tube Type: AKV Ubbelohde, RPVm Ubbelohde