Two positions Polymer viscometer with sampler PSL-Rheotek
The PSL Rheotek RPV-1 (2) RSS Two position polymer viscometer system with smart sampler is suitable for measuring the dilute solution viscosity of a wide range of polymers dissolved in acids, organic solvents or water, including PA, PET, PVC, PLA, PBT, PC, PE, PP, Cellulose Acetate, Inks, bio-polymers and other.
The RPV-1 is designed to be integrated with the SP-1 Sample Preparation system for polymers.
The PSL Rheotek RPV-1 RSS provides a reliable and precise system for measuring dilute solutions of polymers.
The RPV-1 RSS automates the manual steps set out in standard methods, minimizing the variability of results.
Systems can be configured with 1 or 2 measuring positions with the Smart Sampler. Other options include sample
preparation and sample dissolution.
Flow times are measured automatically using ASTM Ubbelohde viscometer tubes supplied with ISO 17025 certificates
of calibration.
Cleaning is carried out in-situ utilizing solvents and a safe vacuum system.
The comprehensive RPV-1 RSS software program records all measurement data as well as calculating a wide range of results.
Standard Practice: |
ASTM D2857 Determination of the dilute solution viscosity of polymers. |
? |
Test Methods General: |
ISO 1628 Part 1 Determination of the reduced viscosity, intrinsic viscosity and K-value of polymers in dilute solution using glass capillary viscometers |
? |
Test Methods Polyamides (PA): |
ISO 307 Determination of viscosity number Polyamides |
? |
Test Methods Poly (Ethylene Terephthalate) PET: |
ASTM D4603 Determination of the Inherent Viscosity of Poly (Ethylene Terephthalate) PET |
ISO 1628 Part 5 Determination of the viscosity number (reduced viscosity) of? Poly (Ethylene Terephthalate) PET, poly (butylene terephthalate) PBT, poly (cyclohexylenedimethylene terephthalate) PCT and poly (ethylene naphthalate) PEN. |
? |
Test Methods Poly Vinyl Chloride (PVC): |
ASTM D1243 Determination of the Inherent Viscosity of vinyl chloride polymers in cyclohexanone. |
ISO 1628 Part 2 Determination of the reduced viscosity (viscosity number) and K-value of PVC resins. |
? |
Other Test Methods: |
ASTM D445 Standard Test Method for determination of kinematic viscosity |
ISO 3104 Petroleum products – determination of kinematic viscosity |
IP 71 Section 1 Kinematic Viscosity |
Polymer |
Test Method |
Solvent |
Concentration |
Temperature |
RSS Measuring Positions |
PA |
ISO 307 |
Formic acid |
0.5% |
25°C |
1 or 2 |
PA |
ISO 307 |
Sulphuric acid |
0.5% |
25°C |
1 or 2 |
PA |
ISO 307 |
M-Cresol |
0.5% |
25°C |
1 or 2 |
PET |
ASTM D4603 |
Pheonol/Tetrachloroethane |
0.5% |
30°C |
1 or 2 |
PET |
Phenol/Dichlorobenzene |
0.5% |
25°C |
1 or 2 |
|
PET |
ISO 1628-5 |
Dichloroacetic acid |
0.5% |
25°C |
1 or 2 |
PVC |
ASTM D1243 |
Cyclohexanone/THF |
0.2% |
30°C |
1 or 2 |
PVC |
ISO 1628-2 |
Cyclohexanone |
0.2% |
25°C |
1 or 2 |
? |
? |
? |
? |
? |
? |
Tube Type: AKV Ubbelohde, RPVm Ubbelohde
Part No. | Ordering Information |
RPV-1 (2) RSS | ?Two positions Polymer Viscometer with Smart Sampler |
Part No. | Options |
RPVS010 | RPV start up kit including glass vials (144 pcs) and plastic caps (500 pcs) |
SIL-OIL | Silicone bath oil |
MIN-OIL | Mineral bath oil |
ACC-1 | Anti-corrosive coating – required for sulfuric acid and DCA applications |
TSC-1 | Third cleaning option – required for sulfuric acid or custom applications. |
SWC/U | Split waste upgrade option |
STATPACK | RPV StatsPack extraction of results to PC or LIMS |