Luma 40/EVO 支架 光學支架 精密溫控樣品池支架

溫度控制的立方座, 具有四個光學端口, 用于 Evolution?300和600分光光度計

The Luma 40/EVO has four optical ports around the cuvette. Use it for absorbance measurements when your experiment requires access at 90 degrees for photochemical activation. Purchase the extended temperature option and run the Luma 40/EVO up to 150 °C for non-aqueous samples. Add a Windowed Jacket, purge with dry gas and run the temperature down to at least -40 °C. The Luma 40 is also ideal for work in the biological range of 0 °C to 110 °C. Use it to observe absorbance spectra at precisely maintained temperatures, or for temperature ramping, to observe how absorbance changes with temperature. Operate the TC 1/Single Temperature Controller using the menu button or control via optional program T-App.
luma 40/evo 在 cuvette 周圍有四個光學端口。當您的實驗需要在90度的溫度下進行光化學激活時, 使用它進行吸收測量。購買擴展溫度選項, 并運行 luma 40/evo 高達150°c 的非水樣。加入一個風夾克, 用干氣清洗, 并將溫度降至-40°c。luma 40 也是在0°c 至110°c 的生物范圍內工作的理想選擇。使用它來觀察在精確保持溫度下的吸收光譜, 或在溫度下傾斜, 觀察吸收率如何隨溫度變化。使用菜單按鈕操作 tc 半溫度控制器, 或通過可選程序 t-app 進行控制。

Product Features產品特點

Four optical ports?四個光學端口
Rapid, precise temperature control?快速、精確的溫度控制
Optional extended temperature range?可選的擴展溫度范圍
Windowed jacket available for temperature extremes?可用于極端溫度的風裝夾克
Variable speed magnetic stirring?變速磁攪拌
Dry gas purge for work at low temperature?低溫工作用干氣凈化
Base and post for mounting in spectrometer?光譜儀安裝的基礎和立柱
Probe input for sample temperature?樣品溫度的探頭輸入
NIST-traceable temperature calibration?nist 可追溯溫度校準
Default stirring speed: 1200 rpm?默認攪拌速度: 1200 轉/分
Stirring speed best performance: 900-1800 rpm?攪拌速度最佳性能: 900-1800 rpm

Technical Specifications

Number of cuvettes controlled:1
Typical use:Fluorescence
Standard cuvette size (outside):12.5 mm x 12.5 mm
Optical ports per cuvette:4
Optical port dimensions:12 mm high x 10 mm wide
Built-in optical slit holders:4 per cuvette
Cuvette z-height:8.5 or 15 mm for most models
Windowed jacket available:2, 3 or 4 windows
Normal factory set temperature range:-40 °C to +105 °C
Temperature range easily achievable:-15 °C to +105 °C
Range with special techniques:-40 °C to +105 °C
Extended factory set temperature range:-55 °C to +150 °C
Extended temperature range achievable:-50 °C to +150 °C
Temperature precision:±0.02 °C
Temperature accuracy:Better than ±0.15 °C from 0 ?C to +80 ?C
Accuracy greater range:Better than ±0.3 ?C from ‐20 ?C to +110 ?C
Temperature reproducibility:Better than ±0.07 °C
Thermistor probes accepted:Series 400 or Series 500
Magnetic stirring motor type:Stepper
Magnetic stirring speed range:1-2500 rpm
Default stirring speed:1200 rpm
Stirring speed best performance:60-1800 rpm

Basic Package
Luma 40 – Temperature-controlled cuvette holder (standard z-height = 15 mm)
TC 1/Single – Temperature Controller
Base plate
Bath 10 – Circulator
NIST-traceable calibration and performance data
Accessories – Magnetic stir bar, tubing, cables, optical slits and opaque cap