t2x2 Sport/EVO
Dual temperature control for the Evolution 300 and 600 Spectrophotometers ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? Evolution?300和600分光光度計的雙溫度控制
產品概述
The t2x2 Sport/EVO is an inexpensive, compact pair of cuvette holders providing independent Peltier temperature control for both the sample and reference cuvettes. Use it for temperature ranges of about -15 °C to 110 °C. It is ideal for most biological studies to observe absorbance spectra at precisely maintained temperatures. If necessary, run the sample and reference cuvettes at different temperatures. The t2x2 Sport/EVO consists of two separate cuvette holders, one for the sample and one for the reference, that mount in the spectrophotometer with utilities conveniently routed under the front panel of the instrument. Operate the TC 1/Dual Temperature Controller using the menu button or control via optional program T-App.
t2x2 sportyevo 是一種價格低廉、結構緊湊的一對試劑盒支架, 為樣品和參考試劑盒提供獨立的 peltier 溫度控制。在-15°c 至110°c 的溫度范圍內使用。它是大多數生物研究的理想選擇, 在精確保持的溫度下觀察吸收光譜。如有必要, 請在不同溫度下運行樣品和參考試劑盒。t2x2 sportyevo 由兩個獨立的 cuvette 支架組成, 一個用于樣品, 另一個用于參考, 該支架安裝在分光光度計中, 在儀器的前面板下方便地將實用程序路由。使用菜單按鈕操作 tc 半溫度控制器, 或通過可選程序 t-app 進行控制。
Product Features 產品特征
Temperature control for both sample and reference?樣品和參考的溫度控制
Variable speed magnetic stirring變速磁攪拌
Dry gas purge for work at low temperature ?低溫工作用干氣凈化
Bases and posts for mounting in the spectrophotometer?分光光度計中的安裝基座和立柱
Cuvette lifters for removal of cuvettes ?用于去除切割機的刮板提升機
Probe input for sample temperature 樣品溫度的探頭輸入
NIST-traceable temperature calibration?nist 可追溯溫度校準
產品參數:
Number of cuvettes controlled: 2
Typical use: Absorbance (sample and reference)
Standard cuvette size (outside) :12.5 mm x 12.5 mm
Optical ports per cuvette: 2
Optical port dimensions:12 mm high x 10 mm wide
Windowed jacket available: No
Factory set temperature range: -40 °C to +110 °C
Temperature range easily achievable: -15 °C to +110 °C
Temperature precision: ±0.02 °C
Temperature accuracy: Better than ±0.15 °C from 0 ?C to +80 ?C
Accuracy full range: Better than ±0.3 ?C from ‐15 ?C to +110 ?C
Temperature reproducibility: Better than ±0.07 °C
Thermistor probes accepted: Series 400 or Series 500
Magnetic stirring motor type: DC
Magnetic stirring speed range: 100-2500 rpm
Default stirring speed: 1200 rpm
Stirring speed best performance: 200-1800 rpm
Basic:
Packaget2x2 Sport – Pair of cuvette holders
TC 1/Dual – Temperature Controller
Base plates, posts (standard?z-height?= 15 mm)
BATH 10?– Circulator
NIST-traceable calibration?and performance data
Accessories –?Two magnetic stir bars, tubing and cables
Accessories:
T-App
Water Circulators
Cuvette Adapters
Thermistor Probes