加拿大Real Tech REAL UV254 ANALYZER 實(shí)時(shí)UV254分析儀
參數(shù): UVT, UV254
UV254分析儀
Real Tech的在線UV254/UVT分析儀可快速實(shí)時(shí)測量水或廢水中的有機(jī)物輸出,如UV254(cm-1)或紫外線透射率/UVT(%)。UV254分析儀利用254nm波長的光,因?yàn)榇蠖鄶?shù)有機(jī)化合物,特別是芳香族有機(jī)物,吸收該波長的光。得益于我們創(chuàng)新的Ortho Beam和Split Sense Pro技術(shù),可以輸出準(zhǔn)確可靠的測量結(jié)果,從而實(shí)現(xiàn)有機(jī)物監(jiān)測的最高可信度。
連續(xù)有機(jī)監(jiān)測可以為許多應(yīng)用帶來重大價(jià)值,包括紫外線消毒性能和效率、混凝劑量優(yōu)化、DBP形成潛力、水源水監(jiān)測等。
功能和優(yōu)點(diǎn)
實(shí)用、準(zhǔn)確且價(jià)格合理
實(shí)時(shí)UVT或UV254有機(jī)物監(jiān)測
專利技術(shù)提供卓越的測量性能
操作人員友好,低維護(hù)設(shè)計(jì)
廢水至高純度測量范圍
4行x 20字符背光LCD顯示屏
創(chuàng)新的自定義校準(zhǔn)功能
安裝簡單,操作方便
CHARACTERISTIC | TECHNICAL DATA |
Path Lengths | 1, 2, 4, 8 mm (M2000 series) 10 x 20 mm (M3000) 50, 100, 150, 250 mm (M4000 series) |
Parameters | UVT, UV254 |
Range | Depends on model selected. Refer to range chart |
Accuracy | ± 0.5% FS |
Units | % or cm-1?(mg/L correlated value) |
Sampling Time | 10 seconds |
Calibration | In-situ zeroing to any sample with known UVT. No further calibration required. |
Cleaning | In-situ cleaning makes cleaning quick and easy. Automatic chemical cleaning is optional. |
Self-Diagnostic | Detection and diagnosis of internal system fault |
Operator Interface | Five push buttons to control a comprehensive hierarchical menu system |
Display | 4 line x 20 character backlit LCD with LED alarm indicator |
Alarms | Dry contact terminals allow operator configurable alarms for: high and low UVT/UVA set points, low lamp output, leak detected, system fault, etc. |
Humidity Control | Humidity sensor with large regeneratable desiccant system |
Outputs | Self-powered 4-20mA, RS232 serial for PC |
Wavelengths | 253.7 nm (optional 550 nm turbidity compensation upgrade) |
Light Source | Low-pressure mercury UV lamp |
Lamp Life | 2 years |
Flow Rate | 300 – 1000 mL/min |
Pressure Rating | 20 PSI maximum |
Fluid Connections | 1/4″ OD tube push-in fittings |
Wetted Materials | Kynar, Polyethylene, Quartz, SS 316L, Viton |
Electrical | 24VDC 40W power adapter (accepts 90-250VAC 50/60Hz) |
Ambient Temp. | 0 to 45°C (32 to 113°F) |
Water Temp. | 0 to 90°C (32 to 194°F) at 21°C (69.8°F) Ambient temperature |
Storage Temp. | -20 to 60°C (-4 to 140°F) |
Enclosure | NEMA 4X, wall mountable |
Weight | 22 lb (M2000 series & M3000) 24 lb (M4000 series) |
Dimensions | 17”H x 14.25”W x 7.5”D (M2000 series & M3000) 17.75”H x 15.5”W x 6.75”D (M4000 series) |
Technology | Ortho-Beam (M3000) Split-Sense Pro (M2000 & M4000 series) |
Analyzer Upgrades | Turbidity Comp. Upgrade, Cellular Modem, Dual Transmitter |