7045 Room Tritium-in-Air Monitor 室內(nèi)測(cè)氚儀

Tyne Engineering’s new Model 7045 Room Tritium In-Air Monitor is a wall or rackmount version of our popular Model 7043 Portable Tritium Monitor. The 7045 is intended for room monitoring for both tritium and gamma. Tyne的新型7045室氚空氣監(jiān)測(cè)器是我們流行的型號(hào)7043便攜式氚監(jiān)測(cè)器的墻或機(jī)架式版本。7045的目的是為氚和伽瑪?shù)姆块g監(jiān)測(cè)。

Specifications

Measuring chamber effective volume 1.5 L, (2 X 0.75L)
Pump Positive displacement gas pump: 12 VDC, flow rate can be up to 11L/min, continuous pressure 8 psig.
Tritium measuring range 0.2μCi/m3 (7,400Bq/ m3) to 1Ci/m3
4 chambers cruciform configuration: two for measuring and two for compensation
Radiation measured measuring total tritium, HTO, gamma and alpha
Sensitivity 0.2μCi/m3 (0.01 DAC)
Accuracy 0.4μCi/m3 from 0 to 100μCi/m3; ±10% from 100μCi/m to 1Ci/m3;
Zero stability ±0.4μCi/m3;
Gamma measurement Gamma is measured simultaneously with tritium. Measuring range is from 0.1mR/h to 10 R/hr;
Radon compensation and tritium discrimination Instrument can provide radon compensation and discriminate in a field of HTO and elemental H3 using the silica gel drier.
Gamma background compensation less than ±10% or 5mCi/m3 reading change whichever is greater response to 20mR/Hr;
Ion trap built into each ion chamber;
Flow rate 0 to 11 L/min
Response time 2 to 5s with 0-15 m air hose, within 20s with hose from 100 to 150m at 90% of signal
Stability : ±3% per 24 hours, ±10% per 30 days;
Analog Output 0-3V linear.
Alarms Tritium, gamma, air flow, detector failure, micro processor alarms in field as well as on optional remote display system through analog output (4 to 20mA)
Alarm Response < 30S with 2-150m hose;
Purge decontamination Chambers can be heated by a cartridge heater controlled by the unit to assist in purging,
Condensation Prevention With heater cartridge temperature can be raised above ambient to prevent condensation in instrument
Communication port RS232 (short distance) and RS485-bus (long distance);
Data Logging frequency The tritium value can be logged every minute and can be time and date stamped. (Gamma is not logged)
Displays One (1) TFT LCD large touch screen display (size 2.8’’), displays the values of tritium, gamma in both numerical and graphical format; one LED screen ?’’ letters, 7 letter screen.
Power supply 220VAC (±10%); Power consumption < 1A
Drier silica gel cylinder is provided with the unit;
Temperature operation range 0 to 50oC degree;
Humidity operation range 0-90% Non-condensable
Size Approx 9″High x 12″Deep x 19″ Wide;
Weight Approx.: 55lb;
Mounting Unit is designed for table-top, 19” rack, or wall-mounting (bracket optional)