Tyne’s Area Gamma Monitor is a system to continuously measure & monitor gamma radiation at designated locations providing alarm control, self calibration, and data logging functions. It provides local audible and visual alarms as well as control and logging from a central computer.
The system meets stringent nuclear qualification requirements such as radiation high dose, temperature, humidity, EMC/EMI, as well as Category III software.
Tyne 伽瑪顯示器是一個系統, 連續測量和監測伽瑪輻射在指定地點提供報警控制, 自標定和數據記錄功能。它提供本地聲音和視覺警報, 以及控制和記錄從中央計算機。
該系統滿足嚴格的核資格要求, 如輻射高劑量, 溫度, 濕度, 電磁兼容/EMI, 以及第三類軟件。
Specifications
Detector | Dual Ion chamber. LND501 and LND50343 to cover range 0.1mR/Hr to 100R/Hr.
Compared with GM tubes, which have 5×10^10 counts limit, the Ion chambers have a much longer life and higher reliability. |
Detector circuit | The radiation dose test detector signal will transmit to measurement unit via balanced-line transmission. |
Check source | Check source with motor drive mechanism.
10uCi Cs137 is built into each detector box. A motor moves the check source close to the detector to check the response/calibration of detector. |
Measuring Module | NIM double width module, built using a real-time micro-controller. |
Alarm Module | NIM signal width module will provide all the relay and local audible & visible alarm. |
Remote module | NEMA type 4 box module with alarm indication, audible alarm, exit sign. It communicates with measuring unit via RS485. |
Central computer with Data trending, data logging. | Designed in VB.net. |
Qualification | Radiation Dose for detector module
Temp/Humidity: 50oC/95%RH EMC/EMI Software qualification: Category III software |